Solitary Parathyroid Adenoma Localization in Technetium Tc99m Sestamibi SPECT and Multiphase Multidetector 4D CT
Open Access
- 6 December 2018
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 40 (1) , 142-149
Abstract
BACKGROUND AND PURPOSE: Minimally invasive parathyroid surgery relies critically on image guidance, but data comparing the efficacy of various imaging modalities are scarce. Our aim was to perform a blinded comparison of the localizing capability of technetium Tc99m sestamibi SPECT, multiphase multidetector 4D CT, and the combination of these 2 modalities (technetium Tc99m sestamibi SPECT + multiphase multidetector 4D CT). MATERIALS AND METHODS: We reviewed the records of 31 (6 men, 25 women; median age, 56 years) consecutive patients diagnosed with biochemically confirmed primary hyperparathyroidism between November 2009 and March 2010 who underwent preoperative technetium Tc99m sestamibi SPECT and multiphase multidetector 4D CT performed on the same scanner with pathologic confirmation by resection of a single parathyroid adenoma. Accuracy was determined separately for localization to the correct side and quadrant using surgical localization as the standard of reference. RESULTS: Surgical resection identified 14 left and 17 right parathyroid adenomas and 2 left inferior, 12 left superior, 11 right inferior, and 6 right superior parathyroid adenomas. For left/right localization, technetium Tc99m sestamibi SPECT achieved an accuracy of 93.5% (29 of 31), multiphase multidetector 4D CT achieved 96.8% accuracy (30 of 31), and technetium Tc99m sestamibi SPECT + multiphase multidetector 4D CT achieved 96.8% accuracy (30 of 31). For quadrant localization, technetium Tc99m sestamibi SPECT accuracy was 67.7% (21 of 31), multiphase multidetector 4D CT accuracy was 87.1% (27 of 31), and technetium Tc99m sestamibi SPECT + multiphase multidetector 4D CT accuracy was 93.5% (29 of 31). Reader diagnostic confidence was consistently ranked lowest for technetium Tc99m sestamibi SPECT and highest for technetium Tc99m sestamibi SPECT + multiphase multidetector 4D CT. CONCLUSIONS: For left/right localization of parathyroid adenomas, all modalities performed equivalently. For quadrant localization, technetium Tc99m sestamibi SPECT + multiphase multidetector 4D CT is superior to technetium Tc99m sestamibi SPECT.Keywords
This publication has 26 references indexed in Scilit:
- Localization of Parathyroid Adenoma by 11C-Choline PET/CTClinical Nuclear Medicine, 2014
- Primer on the Metabolic Bone Diseases and Disorders of Mineral Metabolism2013
- Ultrasound for Localization in Primary HyperparathyroidismOtolaryngology–Head and Neck Surgery, 2013
- Accurate Preoperative Localization of Parathyroid Adenomas With C-11 Methionine PET/CTAnnals of Surgery, 2013
- Can Ultrasound Be Used as the Primary Screening Modality for the Localization of Parathyroid Disease prior to Surgery for Primary Hyperparathyroidism? A Review of 440 CasesORL, 2011
- Single Photon Emission Computed Tomography (SPECT) Should be Routinely Performed for the Detection of Parathyroid Abnormalities Utilizing Technetium-99m Sestamibi Parathyroid ScintigraphyClinical Nuclear Medicine, 2009
- Preoperative 99Tcm-sestamibi scintigraphy with SPECT localizes most pathologic parathyroid glandsLangenbeck's Archives of Surgery, 2009
- Surgical strategy for sporadic primary hyperparathyroidism an evidence-based approach to surgical strategy, patient selection, surgical access, and reoperationsLangenbeck's Archives of Surgery, 2009
- Computed tomography and magnetic resonance imaging in diseases of the thyroid and parathyroidEuropean Journal of Radiology, 2008
- Improved preoperative planning for directed parathyroidectomy with 4-dimensional computed tomographySurgery, 2006