Abstract
In most electrolytes the peak potentials of tin and lead are so close together that a voltammetric determination is impossible. Difficulties occur especially if one of the metals is present in excess. The simultaneous anodic stripping voltammetric analyses of lead and tin in ancient archaeometallurgical samples have been studied. Two different electrolytes were used; cetyltrimethylammonium bromide in a mixture of citrate and oxalate buffer, and methylene blue in oxalate buffer. Cetyltrimethylammonium bromide was found to be unsuitable for the determination of tin; the tin peak was asymmetric and often split. Methylene blue was studied at pH values of 1.35, 1.60, 1.80, 2.00, 2.68, 3.00 and 3.15. Differential pulse voltammograms were obtained between −800 mV and −250 mV. It was concluded that as pH was increased the corresponding half-wave potentials, E 1/2, for tin and lead were shifted to more negative values and the sensitivity of the simultaneous determination of tin and lead was decreased. However, tin and lead concentrations could be determined simultaneously in oxalate buffer and in the presence of methylene blue at about pH 1.6.Keywords
This publication has 19 references indexed in Scilit:
- Contribution of migration current to the voltammetric deposition and stripping of lead with and without added supporting electrolyte at a mercury-free carbon fibre microdisc electrodeAnalytica Chimica Acta, 2003
- Differential pulse cathodic stripping adsorption voltammetric determination of trace amounts of lead using factorial design for optimizationTalanta, 2003
- Determination of trace tin in foods by single-sweep polarographyFood Chemistry, 1999
- Simultaneous determination of tin, lead and molybdenum by differential-pulse polarographyThe Analyst, 1994
- A new continuous hydride generator for the determination of arsenic, Antimony and tin by hybride generation atomic absorption spectrometryAnalytica Chimica Acta, 1992
- Determination of progesterone based on the enhancement effect of surfactants in linear sweep polarographyAnalytica Chimica Acta, 1991
- Anodic-stripping voltammetry of heavy metals in the presence of organic surfactantsTalanta, 1989
- Determination of tin in the ng g−1 range differential pulse polarographyAnalytica Chimica Acta, 1986
- Determination of tin and lead by differential pulse polarography with addition of hyamine-2389Analytica Chimica Acta, 1985
- Simultaneous determination of tin and lead by a.c. anodic stripping voltammetry at a hanging mercury drop electrode sensitized by cetyltrimethylammoniuAnalytica Chimica Acta, 1982