Neylan Dirilgen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Neylan Dirilgen has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
F. Dogan
Department of Chemistry , Boğaziçi University , Bebek‐Istanbul, Turkey
1 shared publicationFulya Dogan
1 shared publicationFulya Doğan
Department of Chemistry, Boğaziçi University, Bebek P.K.2, İstanbul, Turkey
1 shared publicationH. Ozbal
Department of Chemistry , Boğaziçi University , Bebek‐Istanbul, Turkey
1 shared publication
Latest Publications
- 1 January 2011
- Published by Elsevier in Ecotoxicology and Environmental Safety
- Vol. 74 (1) , 48-54
Mercury and lead: Assessing the toxic effects on growth and metal accumulation by Lemna minor
- 1 January 2011
- Published by Elsevier in Ecotoxicology and Environmental Safety
- Vol. 74 (1) , 48-54
Mercury and lead: Assessing the toxic effects on growth and metal accumulation by Lemna minor
- 1 January 2006
- Published by Taylor & Francis in Analytical Letters
- Vol. 39 (1) , 127-143
Anodic Stripping Voltammetry: Arsenic Determination in Ancient Bone Samples
A highly sensitive method for the determination of arsenic (As) content in ancient bone samples was studied using a gold tipped rotating disc electrode and differential pulse anodic stripping voltammetry. Factors affecting sensitivity and precision, including electrolyte concentration, deposition potential, deposition time, and rotation rate were investigated. Electroinactive As(V) was reduced to As(III) by HCl 30% w/v prior to electroanalytical measurements. For a deposition time of 120 sec, the lowest detection limit (LOD) for arsenic was 1.078 µg/L. Optimized working conditions are defined as a deposition potential of −1200 mV with a deposition time of 120 sec, 10 M HCl as the supporting electrolyte, and a rotation rate of 2000 rpm. Results of electroanalytial measurements in ancient bone samples are compared with those obtained from the hydride generation atomic absorption spectroscopy (HG‐FAAS) analysis. Analytical relevancy of the two methods was then compared with the aid of statistical data treatment.
- 1 January 2006
- Published by Taylor & Francis in Analytical Letters
- Vol. 39 (1) , 127-143
Anodic Stripping Voltammetry: Arsenic Determination in Ancient Bone Samples
A highly sensitive method for the determination of arsenic (As) content in ancient bone samples was studied using a gold tipped rotating disc electrode and differential pulse anodic stripping voltammetry. Factors affecting sensitivity and precision, including electrolyte concentration, deposition potential, deposition time, and rotation rate were investigated. Electroinactive As(V) was reduced to As(III) by HCl 30% w/v prior to electroanalytical measurements. For a deposition time of 120 sec, the lowest detection limit (LOD) for arsenic was 1.078 µg/L. Optimized working conditions are defined as a deposition potential of −1200 mV with a deposition time of 120 sec, 10 M HCl as the supporting electrolyte, and a rotation rate of 2000 rpm. Results of electroanalytial measurements in ancient bone samples are compared with those obtained from the hydride generation atomic absorption spectroscopy (HG‐FAAS) analysis. Analytical relevancy of the two methods was then compared with the aid of statistical data treatment.
- 15 September 2004
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 84 (11) , 855-864
Anodic stripping voltammetry: sn and pb analysis in archaeometallurgical samples
In most electrolytes the peak potentials of tin and lead are so close together that a voltammetric determination is impossible. Difficulties occur especially if one of the metals is present in excess. The simultaneous anodic stripping voltammetric analyses of lead and tin in ancient archaeometallurgical samples have been studied. Two different electrolytes were used; cetyltrimethylammonium bromide in a mixture of citrate and oxalate buffer, and methylene blue in oxalate buffer. Cetyltrimethylammonium bromide was found to be unsuitable for the determination of tin; the tin peak was asymmetric and often split. Methylene blue was studied at pH values of 1.35, 1.60, 1.80, 2.00, 2.68, 3.00 and 3.15. Differential pulse voltammograms were obtained between −800 mV and −250 mV. It was concluded that as pH was increased the corresponding half-wave potentials, E 1/2, for tin and lead were shifted to more negative values and the sensitivity of the simultaneous determination of tin and lead was decreased. However, tin and lead concentrations could be determined simultaneously in oxalate buffer and in the presence of methylene blue at about pH 1.6.
- 15 September 2004
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 84 (11) , 855-864
Anodic stripping voltammetry: sn and pb analysis in archaeometallurgical samples
In most electrolytes the peak potentials of tin and lead are so close together that a voltammetric determination is impossible. Difficulties occur especially if one of the metals is present in excess. The simultaneous anodic stripping voltammetric analyses of lead and tin in ancient archaeometallurgical samples have been studied. Two different electrolytes were used; cetyltrimethylammonium bromide in a mixture of citrate and oxalate buffer, and methylene blue in oxalate buffer. Cetyltrimethylammonium bromide was found to be unsuitable for the determination of tin; the tin peak was asymmetric and often split. Methylene blue was studied at pH values of 1.35, 1.60, 1.80, 2.00, 2.68, 3.00 and 3.15. Differential pulse voltammograms were obtained between −800 mV and −250 mV. It was concluded that as pH was increased the corresponding half-wave potentials, E 1/2, for tin and lead were shifted to more negative values and the sensitivity of the simultaneous determination of tin and lead was decreased. However, tin and lead concentrations could be determined simultaneously in oxalate buffer and in the presence of methylene blue at about pH 1.6.
- 1 November 2002
- Published by Elsevier in Ecotoxicology and Environmental Safety
- Vol. 53 (3) , 397-403
Speciation of chromium in the presence of copper and zinc and their combined toxicity
- 1 November 2002
- Published by Elsevier in Ecotoxicology and Environmental Safety
- Vol. 53 (3) , 397-403
Speciation of chromium in the presence of copper and zinc and their combined toxicity