Impacts of Air Density Fluctuations Toward the Mass Measurements of a 1 kg Silicon Sphere
Open Access
- 30 July 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 140840-140847
Abstract
After the revision of the International System of Units (SI) in May 2019, the Planck constant h became the top of the dissemination system for the kilogram. However, the Planck constant is difficult or impractical to use in daily calibrations. Thus, in many applications, alternative physical artefacts are used as mass standards for dissemination. Mass measurements of silicon spheres for the determination of Avogadro and Planck constants have shown that silicon spheres possess stability with high accuracy, thus can be utilized as mass standards. However, the material and the geometry properties of silicon spheres are different from classic mass standards commonly used for the dissemination of the kilogram. It is therefore necessary to determine mass corrections of silicon spheres to improve mass measurements. The effect of air density fluctuations in air buoyancy correction of silicon spheres mass measurements is investigated in this paper. Six types of air density fluctuations for three different weighing processes are summarized. In addition, a method to minimize the impact of air density fluctuation by applying real-time air density data to estimate the air buoyancy correction is proposed. Mass comparisons using a 1 kg silicon sphere and classic mass standards in various materials were conducted for method verification. Results show that the improved method using the real-time air density of each alternative weighing process can reduce the measurement errors by 8.7 μg to 39.0 μg in the air buoyancy correction, which is not negligible when performing high accuracy mass measurements for the dissemination of the redefined SI mass unit using silicon spheres.Keywords
Funding Information
- National Key Research and Development Program for National Quality Infrastructure (2016YFF0200103)
- Special-Funded Program through the National Key Scientific Instruments and Equipment Development (2012YQ90208)
- National Science and Technology Support Program (2011BAK15B06)
This publication has 11 references indexed in Scilit:
- Status of the Realization and Dissemination of the Kilogram via Silicon Spheres2018
- Contributions of precision engineering to the revision of the SICIRP Annals, 2017
- Realization of the kilogram by the XRCD methodMetrologia, 2016
- Mass Measurement of 1-kg Silicon Spheres for Determination of the Avogadro and Planck ConstantsIEEE Transactions on Instrumentation and Measurement, 2015
- Counting the atoms in a28Si crystal for a new kilogram definitionMetrologia, 2011
- Revised formula for the density of moist air (CIPM-2007)Metrologia, 2008
- Primary mass calibration of silicon spheresMeasurement Science and Technology, 2006
- Methods to determine water vapour sorption on mass standardsMetrologia, 2004
- Determination of the amount of gas adsorption on SiO2/Si(100) surfaces to realize precise mass measurementMetrologia, 2004
- Cycles of comparison measurements, uncertainties and efficienciesMeasurement Science and Technology, 1999