Silicon carbide X-ray beam position monitors for synchrotron applications
Open Access
- 1 January 2019
- journal article
- research article
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 26 (1) , 28-35
Abstract
In this work, the performance of thin silicon carbide membranes as material for radiation hard X-ray beam position monitors (XBPMs) is investigated. Thermal and electrical behavior of XBPMs made from thin silicon carbide membranes and single-crystal diamond is compared using finite-element simulations. Fabricated silicon carbide devices are also compared with a 12 µm commercial polycrystalline diamond XBPM at the Swiss Light Source at the Paul Scherrer Institute. Results show that silicon carbide devices can reach equivalent transparencies while showing improved linearity, dynamics and signal-to-noise ratio compared with commercial polycrystalline diamond XBPMs. Given the obtained results and availability of electronic-grade epitaxies on up to 6 inch wafers, it is expected that silicon carbide can substitute for diamond in most beam monitoring applications, whereas diamond, owing to its lower absorption, could remain the material of choice in cases of extreme X-ray power densities, such as pink and white beams.Keywords
This publication has 21 references indexed in Scilit:
- Fabrication of Thick Free-Standing Lightly-Doped n-Type 4H-SiC WafersMaterials Science Forum, 2017
- Ultra-thin optical grade scCVD diamond as X-ray beam position monitorJournal of Synchrotron Radiation, 2014
- Systematic Study of Anodic Etching of Highly Doped N-type 4H-SiC in Various HF Based ElectrolytesJournal of the Electrochemical Society, 2013
- Room light anodic etching of highly doped n-type 4 H-SiC in high-concentration HF electrolytes: Difference between C and Si crystalline facesDiscover Nano, 2012
- Measurements of impact ionization coefficients of electrons and holes in 4H‐SiC and their application to device simulationPhysica Status Solidi (a), 2009
- CVD diamond-based semi-transparent beam-position monitors for synchrotron beamlines: preliminary studies and device developments at CEA/SaclayJournal of Synchrotron Radiation, 2006
- X-ray beam-position monitoring in the sub-micrometre and sub-second regimeJournal of Synchrotron Radiation, 2005
- Measurement of Hall Mobility in 4H-SiC for Improvement of the Accuracy of the Mobility Model in Device SimulationMaterials Science Forum, 2003
- Study of silicon carbide for X-ray detection and spectroscopyIEEE Transactions on Nuclear Science, 2003
- X-Ray Interactions: Photoabsorption, Scattering, Transmission, and Reflection at E = 50-30,000 eV, Z = 1-92Atomic Data and Nuclear Data Tables, 1993