pH-sensitive imaging by low-frequency EPR: a model study for biological applications
Authors:
- Antonello SotgiuASAntonello Sotgiu
- Karsten MäderKarsten Mäder
- Giuseppe PlacidiGiuseppe Placidi
- Cinzia Lucia UrsiniCUCinzia Lucia Ursini
- Marcello AlecciMAMarcello Alecci
- 1 July 1998
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 43 (7) , 1921-1930
Abstract
The use of pH-sensitive nitroxides, in conjunction with low-frequency EPR, offers a unique opportunity for non-invasive assessment of pH values (in the range 0 to 14) in living animals. In the present study, we have investigated the potential use of pH-sensitive nitroxide free radicals in conjunction with EPR imaging techniques at low and very low frequencies (280 MHz - 2.1 GHz). In particular, we have measured the hyperfine splitting (hfs) of a pH-sensitive probe at three different EPR frequencies: 280 MHz, 1.1 GHz and 2.1 GHz. We have also developed EPR imaging experiments with phantoms simulating in vivo conditions, using pH-sensitive probes at 280 MHz (spatial-spatial) and 1.1 GHz (spectral-spatial). Finally, we discuss the actual sensitivity/resolution limits of the EPR imaging techniques at low frequencies. Practical applications of this method in the biomedical field are suggested for the continuous and non-invasive localization of pH in vivo.Keywords
This publication has 28 references indexed in Scilit:
- Noninvasive measurement of the pH inside the gut by using pH‐sensitive nitroxides. An in vivo EPR studyMagnetic Resonance in Medicine, 1996
- In vivo spin-label murine pharmacodynamics using low-frequency electron paramagnetic resonance imagingBiophysical Journal, 1996
- Introduction to EPR imaging using magnetic‐field gradientsConcepts in Magnetic Resonance, 1995
- Simultaneous 280 MHz EPR imaging of rat organs during nitroxide free radical clearanceBiophysical Journal, 1994
- New experimental procedures for in vivo L-band and radio frequency EPR spectroscopy/imagingJournal of the Chemical Society, Perkin Transactions 2, 1993
- Electron paramagnetic resonance spectrometer for three-dimensional in vivo imaging at very low frequencyReview of Scientific Instruments, 1992
- Three-dimensional in vivo ESR imaging in ratsMagnetic Resonance Imaging, 1990
- Low-frequency three-dimensional ESR imaging of large samplesJournal of Physics E: Scientific Instruments, 1988
- Estimation of transmembrane pH gradients from phase equilibriums of spin-labeled aminesBiochemistry, 1978
- Measurement of Nuclear SpinPhysical Review B, 1931