Antonello Sotgiu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Antonello Sotgiu has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Giuseppe Placidi
University of L’Aquila
5 shared publications - Marcello Alecci
Department of Life, Health & Environmental Sciences (MESVA), University of L’Aquila, 67100 L’Aquila, Italy
5 shared publications G. Gualtieri
Dept. of Biological Sciences and Technologies, University of L'Aquila, L'Aquila, Italy
2 shared publicationsS Colacicchi
2 shared publicationsCinzia Lucia Ursini
|| INFM, c/o Centro di Risonanza Magnetica, Collemaggio, Universita' dell'Aquila, Italy
1 shared publicationF Momo
1 shared publication
Latest Publications
- 26 January 2001
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 34 (3) , 313-318
Automatic optimization strategy for the design of circular multipolar magnets
This paper presents an optimization procedure for the design of circular magnets of multipolar symmetry in the presence of an iron screen. The procedure is based on the combined use of field calculations and optimization techniques and can be applied when the field is generated either by a distribution of currents or of magnetic materials. The numerical optimization technique uses the positions and/or orientations of the field generating elements as parameters (currents or permanent magnets). The technique has proved to be very effective in obtaining a good uniformity of field in a large fraction of the magnet volume. It should reduce the subsequent shimming operations. The method is almost completely automatic and simpler than other standard methods normally used to design new magnet geometries which are based on field calculation programs and `manual' optimization procedures.} fnm{4}{Author to whom all correspondence should be addressed.
- 26 January 2001
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 34 (3) , 313-318
Automatic optimization strategy for the design of circular multipolar magnets
This paper presents an optimization procedure for the design of circular magnets of multipolar symmetry in the presence of an iron screen. The procedure is based on the combined use of field calculations and optimization techniques and can be applied when the field is generated either by a distribution of currents or of magnetic materials. The numerical optimization technique uses the positions and/or orientations of the field generating elements as parameters (currents or permanent magnets). The technique has proved to be very effective in obtaining a good uniformity of field in a large fraction of the magnet volume. It should reduce the subsequent shimming operations. The method is almost completely automatic and simpler than other standard methods normally used to design new magnet geometries which are based on field calculation programs and `manual' optimization procedures.} fnm{4}{Author to whom all correspondence should be addressed.
- 1 October 1998
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 9 (10) , 1663-1671
A novel, cylindrical, transverse gradient coil design for magnetic resonance imaging of large samples
Magnetic resonance imaging (MRI) requires the use of three sets of coils to produce magnetic field gradients, one for each axis, to encode three-dimensional information. The magnetic field generated by gradient coils has to change as linearly as possible with distance so as to avoid heavy distortion of the resulting image of the sample. The reduction of the dimensions of the magnets for MRI applications has made it necessary to construct gradient coils that can be placed in reduced spaces and, at the same time, provide the uniformity necessary for MRI. A novel cylindrical gradient coil design is described to perform high-resolution imaging of large samples, having a large cylindrical zone of gradient uniformity, co-axial with the coil. This design, referred to as the butterfly coil, produces a magnetic field along the axis of the cylinder and a field gradient in the perpendicular direction (transverse gradient). The butterfly coil design has been simulated and compared, both in homogeneity and efficiency, with a preceding gradient coil geometry. The coil has been constructed and experimental measurements performed. The aspect ratio, defined as the ratio between the length h and diameter d of the cylinder of the coil, is very low. In fact, mathematical simulations and experimental measurements have been carried out on a gradient coil system having . Despite its low-dimensional ratio, this gradient coil system has been proved to be very accurate, both in uniformity and efficiency, in a relatively great volume.
- 1 October 1998
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 9 (10) , 1663-1671
A novel, cylindrical, transverse gradient coil design for magnetic resonance imaging of large samples
Magnetic resonance imaging (MRI) requires the use of three sets of coils to produce magnetic field gradients, one for each axis, to encode three-dimensional information. The magnetic field generated by gradient coils has to change as linearly as possible with distance so as to avoid heavy distortion of the resulting image of the sample. The reduction of the dimensions of the magnets for MRI applications has made it necessary to construct gradient coils that can be placed in reduced spaces and, at the same time, provide the uniformity necessary for MRI. A novel cylindrical gradient coil design is described to perform high-resolution imaging of large samples, having a large cylindrical zone of gradient uniformity, co-axial with the coil. This design, referred to as the butterfly coil, produces a magnetic field along the axis of the cylinder and a field gradient in the perpendicular direction (transverse gradient). The butterfly coil design has been simulated and compared, both in homogeneity and efficiency, with a preceding gradient coil geometry. The coil has been constructed and experimental measurements performed. The aspect ratio, defined as the ratio between the length h and diameter d of the cylinder of the coil, is very low. In fact, mathematical simulations and experimental measurements have been carried out on a gradient coil system having . Despite its low-dimensional ratio, this gradient coil system has been proved to be very accurate, both in uniformity and efficiency, in a relatively great volume.
- 1 July 1998
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 43 (7) , 1921-1930
pH-sensitive imaging by low-frequency EPR: a model study for biological applications
The use of pH-sensitive nitroxides, in conjunction with low-frequency EPR, offers a unique opportunity for non-invasive assessment of pH values (in the range 0 to 14) in living animals. In the present study, we have investigated the potential use of pH-sensitive nitroxide free radicals in conjunction with EPR imaging techniques at low and very low frequencies (280 MHz - 2.1 GHz). In particular, we have measured the hyperfine splitting (hfs) of a pH-sensitive probe at three different EPR frequencies: 280 MHz, 1.1 GHz and 2.1 GHz. We have also developed EPR imaging experiments with phantoms simulating in vivo conditions, using pH-sensitive probes at 280 MHz (spatial-spatial) and 1.1 GHz (spectral-spatial). Finally, we discuss the actual sensitivity/resolution limits of the EPR imaging techniques at low frequencies. Practical applications of this method in the biomedical field are suggested for the continuous and non-invasive localization of pH in vivo.
- 1 July 1998
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 43 (7) , 1921-1930
pH-sensitive imaging by low-frequency EPR: a model study for biological applications
The use of pH-sensitive nitroxides, in conjunction with low-frequency EPR, offers a unique opportunity for non-invasive assessment of pH values (in the range 0 to 14) in living animals. In the present study, we have investigated the potential use of pH-sensitive nitroxide free radicals in conjunction with EPR imaging techniques at low and very low frequencies (280 MHz - 2.1 GHz). In particular, we have measured the hyperfine splitting (hfs) of a pH-sensitive probe at three different EPR frequencies: 280 MHz, 1.1 GHz and 2.1 GHz. We have also developed EPR imaging experiments with phantoms simulating in vivo conditions, using pH-sensitive probes at 280 MHz (spatial-spatial) and 1.1 GHz (spectral-spatial). Finally, we discuss the actual sensitivity/resolution limits of the EPR imaging techniques at low frequencies. Practical applications of this method in the biomedical field are suggested for the continuous and non-invasive localization of pH in vivo.
- 1 September 1997
- Vol. 43 (6) , 813-23
Water soluble free radicals as biologically responsive agents in electron paramagnetic resonance imaging.
Electron paramagnetic resonance imaging (EPRI) is currently being developed at frequencies between 200 MHz and 2 GHz. EPRI can map the in vivo distribution of paramagnetic species, such as water soluble free radicals; nitroxide free radicals are commonly used. EPR images reflect the complexity of metabolic actions on the exogenous delivered nitroxides. Their reduction rate in vivo is affected by parameters such as oxygen concentration, pH and biodistribution. This paper illustrates the main features of low frequency EPRI and reconstruction techniques. Examples of EPR imaging, such as two-dimensional (2D) spatial mapping of the distribution of a nitroxide free radical in phantoms and in whole rat, are given.
- 1 September 1997
- Vol. 43 (6) , 813-23
Water soluble free radicals as biologically responsive agents in electron paramagnetic resonance imaging.
Electron paramagnetic resonance imaging (EPRI) is currently being developed at frequencies between 200 MHz and 2 GHz. EPRI can map the in vivo distribution of paramagnetic species, such as water soluble free radicals; nitroxide free radicals are commonly used. EPR images reflect the complexity of metabolic actions on the exogenous delivered nitroxides. Their reduction rate in vivo is affected by parameters such as oxygen concentration, pH and biodistribution. This paper illustrates the main features of low frequency EPRI and reconstruction techniques. Examples of EPR imaging, such as two-dimensional (2D) spatial mapping of the distribution of a nitroxide free radical in phantoms and in whole rat, are given.
- 1 June 1996
- Published by Springer Nature in Research on Chemical Intermediates
- Vol. 22 (6) , 549-556
A minimal cavity and its capacitive coupling for in vivo EPR measurements on mice.
A very simple ring resonator for in vivo L-band EPR spectroscopy was built and characterised. It employs a special capacitive coupling that allows measurents to be made on large biological samples which are not possible with other resonators. In spite of its intrinsic low Q it has a sensitivity almost equivalent to that obtained from high Q resonators. These features were tested down to a nitroxide concentration of 10 μM in high conductivity phantoms.
- 1 June 1996
- Published by Springer Nature in Research on Chemical Intermediates
- Vol. 22 (6) , 549-556
A minimal cavity and its capacitive coupling for in vivo EPR measurements on mice.
A very simple ring resonator for in vivo L-band EPR spectroscopy was built and characterised. It employs a special capacitive coupling that allows measurents to be made on large biological samples which are not possible with other resonators. In spite of its intrinsic low Q it has a sensitivity almost equivalent to that obtained from high Q resonators. These features were tested down to a nitroxide concentration of 10 μM in high conductivity phantoms.
- 1 June 1995
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 66 (6) , 3715-3716
Integration of D-shaped gradient coils in a Bruker TM circular cavity for X-band electron spin resonance imaging
A very compact design for the coil assembly of an X‐band imaging apparatus is described. The design is based on D‐shaped coils obtained by cutting a circular current distribution by two parallel chords. The coils make the best possible use of the space available within the particular geometry of a cylindrical Bruker TM110 cavity. Its compact design results in a maximum width of 45 mm, which is available in most electromagnets used for electron paramagnetic resonance (EPR) spectroscopy. Using nitroxide free radicals of 60 mT in linewidth and field gradients of 1.5 mT/cm, a resolution of 100 μm was obtained.
- 1 June 1995
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 66 (6) , 3715-3716
Integration of D-shaped gradient coils in a Bruker TM circular cavity for X-band electron spin resonance imaging
A very compact design for the coil assembly of an X‐band imaging apparatus is described. The design is based on D‐shaped coils obtained by cutting a circular current distribution by two parallel chords. The coils make the best possible use of the space available within the particular geometry of a cylindrical Bruker TM110 cavity. Its compact design results in a maximum width of 45 mm, which is available in most electromagnets used for electron paramagnetic resonance (EPR) spectroscopy. Using nitroxide free radicals of 60 mT in linewidth and field gradients of 1.5 mT/cm, a resolution of 100 μm was obtained.
- 1 January 1993
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 4 (1) , 60-64
Limits of deconvolution in enhancing the resolution in EPR imaging experiments
- 1 January 1993
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 4 (1) , 60-64
Limits of deconvolution in enhancing the resolution in EPR imaging experiments
- 1 October 1992
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 63 (10) , 4263-4270
Electron paramagnetic resonance spectrometer for three-dimensional in vivo imaging at very low frequency
The paper describes an electron paramagnetic resonance apparatus for spectroscopy and imaging at very low frequency (283 MHz). The bridge operates in a reflection cavity homodyne configuration and can be used on a very broad frequency range. The sample cavity is a one loop‐two gap resonator and accepts samples up to 5 cm in diameter and 10 cm long. These sample dimensions make the apparatus suitable for observing living samples such as rats. For the main field and gradients the apparatus uses a newly designed multipolar magnet that can provide the main field and gradients for 2D image reconstruction. The third gradient is obtained by coils mounted in the bore of the magnet. Tests on peroxilamine disulfonate samples have shown micromolar sensitivity. The minimum spatial resolution is limited by the sample linewidth and by the signal/noise. In living samples the toxicity of nitroxide radicals restricts the maximum label concentrations to values of the order of 10−4 M, and the resolution seems to be limited by sensitivity to fractions of cm3.
- 1 October 1992
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 63 (10) , 4263-4270
Electron paramagnetic resonance spectrometer for three-dimensional in vivo imaging at very low frequency
The paper describes an electron paramagnetic resonance apparatus for spectroscopy and imaging at very low frequency (283 MHz). The bridge operates in a reflection cavity homodyne configuration and can be used on a very broad frequency range. The sample cavity is a one loop‐two gap resonator and accepts samples up to 5 cm in diameter and 10 cm long. These sample dimensions make the apparatus suitable for observing living samples such as rats. For the main field and gradients the apparatus uses a newly designed multipolar magnet that can provide the main field and gradients for 2D image reconstruction. The third gradient is obtained by coils mounted in the bore of the magnet. Tests on peroxilamine disulfonate samples have shown micromolar sensitivity. The minimum spatial resolution is limited by the sample linewidth and by the signal/noise. In living samples the toxicity of nitroxide radicals restricts the maximum label concentrations to values of the order of 10−4 M, and the resolution seems to be limited by sensitivity to fractions of cm3.
- 1 January 1991
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 2 (1) , 32-37
Multipolar magnet for low-frequency ESR imaging (with computer controlled power supply)
- 1 January 1991
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 2 (1) , 32-37
Multipolar magnet for low-frequency ESR imaging (with computer controlled power supply)