Enriching 3D optical surface scans with prior knowledge: tissue thickness computation by exploiting local neighborhoods
- 30 June 2015
- journal article
- research article
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 11 (4) , 569-579
Abstract
Purpose Patient immobilization and X-ray-based imaging provide neither a convenient nor a very accurate way to ensure low repositioning errors or to compensate for motion in cranial radiotherapy. We therefore propose an optical tracking device that exploits subcutaneous structures as landmarks in addition to merely spatial registration. To develop such head tracking algorithms, precise and robust computation of these structures is necessary. Here, we show that the tissue thickness can be predicted with high accuracy and moreover exploit local neighborhood information within the laser spot grid on the forehead to further increase this estimation accuracy. Methods We use statistical learning with Support Vector Regression and Gaussian Processes to learn a relationship between optical backscatter features and an MR tissue thickness ground truth. We compare different kernel functions for the data of five different subjects. The incident angle of the laser on the forehead as well as local neighborhoods is incorporated into the feature space. The latter represent the backscatter features from four neighboring laser spots. Results We confirm that the incident angle has a positive effect on the estimation error of the tissue thickness. The root-mean-square error falls even below 0.15 mm when adding the complete neighborhood information. This prior knowledge also leads to a smoothing effect on the reconstructed skin patch. Learning between different head poses yields similar results. The partial overlap of the point clouds makes the trade-off between novel information and increased feature space dimension obvious and hence feature selection by e.g., sequential forward selection necessary.Keywords
This publication has 17 references indexed in Scilit:
- Estimating soft tissue thickness from light-tissue interactions––a simulation studyBiomedical Optics Express, 2013
- Evaluation of the Accuracy of a 3D Surface Imaging System for Patient Setup in Head and Neck Cancer RadiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Initial clinical experience with a frameless and maskless stereotactic radiosurgery treatmentPractical Radiation Oncology, 2012
- Inter- and Intrafraction Patient Positioning Uncertainties for Intracranial Radiotherapy: A Study of Four Frameless, Thermoplastic Mask-Based Immobilization Strategies Using Daily Cone-Beam CTInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- Fractionated stereotactic conformal radiotherapy for large benign skull base meningiomasRadiation Oncology, 2011
- Dysphagia in head and neck cancer patients following intensity modulated radiotherapy (IMRT)Radiation Oncology, 2011
- The Curse of Dimensionality in Data Mining and Time Series Prediction2005
- A tutorial on support vector regressionStatistics and Computing, 2004
- Repositioning accuracy of a commercially available thermoplastic mask systemRadiotherapy and Oncology, 2004
- A method for registration of 3-D shapesIEEE Transactions on Pattern Analysis and Machine Intelligence, 1992