Tobias Wissel
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tobias Wissel has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Achim Schweikard
Institute for Robotics and Cognitive Systems, University of Lübeck, Lübeck, Germany
7 shared publications- Floris Ernst
Universität zu Lübeck, Institut für Robotik und Kognitive Systeme, Ratzeburger Allee 160, Hs. 64, 23562 Lübeck , Germany
7 shared publications Benjamin Wagner
Institute for Robotics and Cognitive Systems, University of Lübeck, Lübeck, Germany; Graduate School for Computing in Medicine and Life Science, University of Lübeck, Lübeck, Germany
4 shared publicationsPatrick Stüber
Institute for Robotics and Cognitive Systems, University of Lübeck, Lübeck, Germany; Graduate School for Computing in Medicine and Life Science, University of Lübeck, Lübeck, Germany
4 shared publications- Achim Schweikard
University of Lübeck
3 shared publications Ralf Bruder
Institute for Robotics and Cognitive Systems, University of Lübeck, Lübeck, Germany
3 shared publications
Latest Publications
- 28 March 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 9 (02) , 025001-20
Cascaded learning in intravascular ultrasound: coronary stent delineation in manual pullbacks
Purpose: Implanting stents to re-open stenotic lesions during percutaneous coronary interventions is considered a standard treatment for acute or chronic coronary syndrome. Intravascular ultrasound (IVUS) can be used to guide and assess the technical success of these interventions. Automatically segmenting stent struts in IVUS sequences improves workflow efficiency but is non-trivial due to a challenging image appearance entailing manifold ambiguities with other structures. Manual, ungated IVUS pullbacks constitute a challenge in this context. We propose a fully data-driven strategy to first longitudinally detect and subsequently segment stent struts in IVUS frames. Approach: A cascaded deep learning approach is presented. It first trains an encoder model to classify frames as “stent,” “no stent,” or “no use.” A segmentation model then delineates stent struts on a pixel level only in frames with a stent label. The first stage of the cascade acts as a gateway to reduce the risk for false positives in the second stage, the segmentation, which is trained on a smaller and difficult-to-annotate dataset. Training of the classification and segmentation model was based on 49,888 and 1826 frames of 74 sequences from 35 patients, respectively. Results: The longitudinal classification yielded Dice scores of 92.96%, 82.35%, and 94.03% for the classes stent, no stent, and no use, respectively. The segmentation achieved a Dice score of 65.1% on the stent ground truth (intra-observer performance: 75.5%) and 43.5% on all frames (including frames without stent, with guidewires, calcium, or without clinical use). The latter improved to 49.5% when gating the frames by the classification decision and further increased to 57.4% with a heuristic on the plausible stent strut area. Conclusions: A data-driven strategy for segmenting stents in ungated, manual pullbacks was presented—the most common and practical scenario in the time-critical clinical workflow. We demonstrated a mitigated risk for ambiguities and false positive predictions.
- 28 March 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 9 (02) , 025001-20
Cascaded learning in intravascular ultrasound: coronary stent delineation in manual pullbacks
Purpose: Implanting stents to re-open stenotic lesions during percutaneous coronary interventions is considered a standard treatment for acute or chronic coronary syndrome. Intravascular ultrasound (IVUS) can be used to guide and assess the technical success of these interventions. Automatically segmenting stent struts in IVUS sequences improves workflow efficiency but is non-trivial due to a challenging image appearance entailing manifold ambiguities with other structures. Manual, ungated IVUS pullbacks constitute a challenge in this context. We propose a fully data-driven strategy to first longitudinally detect and subsequently segment stent struts in IVUS frames. Approach: A cascaded deep learning approach is presented. It first trains an encoder model to classify frames as “stent,” “no stent,” or “no use.” A segmentation model then delineates stent struts on a pixel level only in frames with a stent label. The first stage of the cascade acts as a gateway to reduce the risk for false positives in the second stage, the segmentation, which is trained on a smaller and difficult-to-annotate dataset. Training of the classification and segmentation model was based on 49,888 and 1826 frames of 74 sequences from 35 patients, respectively. Results: The longitudinal classification yielded Dice scores of 92.96%, 82.35%, and 94.03% for the classes stent, no stent, and no use, respectively. The segmentation achieved a Dice score of 65.1% on the stent ground truth (intra-observer performance: 75.5%) and 43.5% on all frames (including frames without stent, with guidewires, calcium, or without clinical use). The latter improved to 49.5% when gating the frames by the classification decision and further increased to 57.4% with a heuristic on the plausible stent strut area. Conclusions: A data-driven strategy for segmenting stents in ungated, manual pullbacks was presented—the most common and practical scenario in the time-critical clinical workflow. We demonstrated a mitigated risk for ambiguities and false positive predictions.
- 2 March 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10574, 41
Deep-learning-based CT motion artifact recognition in coronary arteries
The detection and subsequent correction of motion artifacts is essential for the high diagnostic value of non- invasive coronary angiography using cardiac CT. However, motion correction algorithms have a substantial computational footprint and possible failure modes which warrants a motion artifact detection step to decide whether motion correction is required in the first place. We investigate how accurately motion artifacts in the coronary arteries can be predicted by deep learning approaches. A forward model simulating cardiac motion by creating and integrating artificial motion vector fields in the filtered back projection (FBP) algorithm allows us to generate training data from nine prospectively ECG-triggered high quality clinical cases. We train a Convolutional Neural Network (CNN) classifying 2D motion-free and motion-perturbed coronary cross-section images and achieve a classification accuracy of 94:4% ± 2:9% by four-fold cross-validation.
- 2 March 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10574, 41
Deep-learning-based CT motion artifact recognition in coronary arteries
The detection and subsequent correction of motion artifacts is essential for the high diagnostic value of non- invasive coronary angiography using cardiac CT. However, motion correction algorithms have a substantial computational footprint and possible failure modes which warrants a motion artifact detection step to decide whether motion correction is required in the first place. We investigate how accurately motion artifacts in the coronary arteries can be predicted by deep learning approaches. A forward model simulating cardiac motion by creating and integrating artificial motion vector fields in the filtered back projection (FBP) algorithm allows us to generate training data from nine prospectively ECG-triggered high quality clinical cases. We train a Convolutional Neural Network (CNN) classifying 2D motion-free and motion-perturbed coronary cross-section images and achieve a classification accuracy of 94:4% ± 2:9% by four-fold cross-validation.
- 1 June 2016
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 95 (2) , 810-817
Enhanced Optical Head Tracking for Cranial Radiation Therapy: Supporting Surface Registration by Cutaneous Structures
- 1 June 2016
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 95 (2) , 810-817
Enhanced Optical Head Tracking for Cranial Radiation Therapy: Supporting Surface Registration by Cutaneous Structures
- Open Access
- 1 September 2015
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 1 (1) , 228-231
Tissue segmentation from head MRI: a ground truth validation for feature-enhanced tracking
Accuracy is essential for optical head-tracking in cranial radiotherapy. Recently, the exploitation of local patterns of tissue information was proposed to achieve a more robust registration. Here, we validate a ground truth for this information obtained from high resolution MRI scans. In five subjects we compared the segmentation accuracy of a semi-automatic algorithm with five human experts. While the algorithm segments the skin and bone surface with an average accuracy of less than 0.1 mm and 0.2 mm, respectively, the mean error on the tissue thickness was 0.17 mm. We conclude that this accuracy is a reasonable basis for extracting reliable cutaneous structures to support surface registration.
- 1 September 2015
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 1 (1) , 228-231
Open AccessTissue segmentation from head MRI: a ground truth validation for feature-enhanced tracking
Accuracy is essential for optical head-tracking in cranial radiotherapy. Recently, the exploitation of local patterns of tissue information was proposed to achieve a more robust registration. Here, we validate a ground truth for this information obtained from high resolution MRI scans. In five subjects we compared the segmentation accuracy of a semi-automatic algorithm with five human experts. While the algorithm segments the skin and bone surface with an average accuracy of less than 0.1 mm and 0.2 mm, respectively, the mean error on the tissue thickness was 0.17 mm. We conclude that this accuracy is a reasonable basis for extracting reliable cutaneous structures to support surface registration.
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015 (1094687X) , 7015-7018
Efficient estimation of tissue thicknesses using sparse approximation for Gaussian processes
Highly accurate localization of the human skull is vital in cranial radiotherapy. Marker-less optical head tracking provides a fast and accurate way to monitor this motion. Recent research has given evidence that marker-less tracking of the forehead benefits from tissue thickness information in addition to the 3D surface geometry. Using Gaussian Processes (GPs) tissue thickness is determined from optical backscatter of a sweeping laser. However, the computational complexity of the GPs scales cubically with the number of training samples. A full head scan contains 1024 points, whereas scans from several perspectives may be required for a comprehensive model for each subject. In five subjects, we thus evaluate sparse approximation methods to reduce the computational effort. We found a better - computation time versus root mean square error (RMSE) - tradeoff for a simple subset of data (SoD) technique. The increase of RMSE when dropping data was not found steep enough to justify the computational overhead of a better approximation by inducing point methods (namely FITC). Promising results were, however, obtained when clustering the training data before selecting the subset.
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015 (1094687X) , 7015-7018
Efficient estimation of tissue thicknesses using sparse approximation for Gaussian processes
Highly accurate localization of the human skull is vital in cranial radiotherapy. Marker-less optical head tracking provides a fast and accurate way to monitor this motion. Recent research has given evidence that marker-less tracking of the forehead benefits from tissue thickness information in addition to the 3D surface geometry. Using Gaussian Processes (GPs) tissue thickness is determined from optical backscatter of a sweeping laser. However, the computational complexity of the GPs scales cubically with the number of training samples. A full head scan contains 1024 points, whereas scans from several perspectives may be required for a comprehensive model for each subject. In five subjects, we thus evaluate sparse approximation methods to reduce the computational effort. We found a better - computation time versus root mean square error (RMSE) - tradeoff for a simple subset of data (SoD) technique. The increase of RMSE when dropping data was not found steep enough to justify the computational overhead of a better approximation by inducing point methods (namely FITC). Promising results were, however, obtained when clustering the training data before selecting the subset.
- 30 June 2015
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 11 (4) , 569-579
Enriching 3D optical surface scans with prior knowledge: tissue thickness computation by exploiting local neighborhoods
Purpose Patient immobilization and X-ray-based imaging provide neither a convenient nor a very accurate way to ensure low repositioning errors or to compensate for motion in cranial radiotherapy. We therefore propose an optical tracking device that exploits subcutaneous structures as landmarks in addition to merely spatial registration. To develop such head tracking algorithms, precise and robust computation of these structures is necessary. Here, we show that the tissue thickness can be predicted with high accuracy and moreover exploit local neighborhood information within the laser spot grid on the forehead to further increase this estimation accuracy. Methods We use statistical learning with Support Vector Regression and Gaussian Processes to learn a relationship between optical backscatter features and an MR tissue thickness ground truth. We compare different kernel functions for the data of five different subjects. The incident angle of the laser on the forehead as well as local neighborhoods is incorporated into the feature space. The latter represent the backscatter features from four neighboring laser spots. Results We confirm that the incident angle has a positive effect on the estimation error of the tissue thickness. The root-mean-square error falls even below 0.15 mm when adding the complete neighborhood information. This prior knowledge also leads to a smoothing effect on the reconstructed skin patch. Learning between different head poses yields similar results. The partial overlap of the point clouds makes the trade-off between novel information and increased feature space dimension obvious and hence feature selection by e.g., sequential forward selection necessary.
- 30 June 2015
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 11 (4) , 569-579
Enriching 3D optical surface scans with prior knowledge: tissue thickness computation by exploiting local neighborhoods
Purpose Patient immobilization and X-ray-based imaging provide neither a convenient nor a very accurate way to ensure low repositioning errors or to compensate for motion in cranial radiotherapy. We therefore propose an optical tracking device that exploits subcutaneous structures as landmarks in addition to merely spatial registration. To develop such head tracking algorithms, precise and robust computation of these structures is necessary. Here, we show that the tissue thickness can be predicted with high accuracy and moreover exploit local neighborhood information within the laser spot grid on the forehead to further increase this estimation accuracy. Methods We use statistical learning with Support Vector Regression and Gaussian Processes to learn a relationship between optical backscatter features and an MR tissue thickness ground truth. We compare different kernel functions for the data of five different subjects. The incident angle of the laser on the forehead as well as local neighborhoods is incorporated into the feature space. The latter represent the backscatter features from four neighboring laser spots. Results We confirm that the incident angle has a positive effect on the estimation error of the tissue thickness. The root-mean-square error falls even below 0.15 mm when adding the complete neighborhood information. This prior knowledge also leads to a smoothing effect on the reconstructed skin patch. Learning between different head poses yields similar results. The partial overlap of the point clouds makes the trade-off between novel information and increased feature space dimension obvious and hence feature selection by e.g., sequential forward selection necessary.
- 22 June 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9529, 95291C
Feasibility test of line sensors for optical tissue thickness estimation
Purpose Line sensors are cheap, fast and have high quantum effciencies. Here, we investigate whether these sensors can replace an area image sensor for the purpose of tissue thickness measurements. Material and Methods As part of a subject study high dynamic range (HDR) images of three subjects were acquired with an area image sensor. To simulate a line sensor as realistic as possible single or multiple lines were extracted from these HDR images. Thereby, horizontally extracted lines correspond to a parallel orientation of the line sensor relative to the incident angle of a laser beam. Vertically extracted lines correspond to an orthogonal orientation. Then, optical features were determined and converted into a tissue thickness using a machine learning algorithm. Results For the tested subjects the worst root mean square error (RMSE) of the learning process was 0:385 mm. The best RMSE was 0:222 mm. For all subjects, the mean RMSE and the standard deviation of RMSE values decreases with a larger number of extracted lines. The orientation of the line sensor turned out to be important for the RMSE. Vertically oriented line sensors achieve lower RMSEs than horizontally oriented sensors because of the influence of the incident angle. Furthermore, the head-pose of the subject seems to be important for the accuracy. Conclusion Line sensors deliver comparable results to previously analysed area image sensors. Nevertheless, the scattering of the values is higher and the size and orientation of the sensor and the head-pose have an influence on the RMSE of the learning process. Therefore, line sensors are feasible for tissue thickness estimation but they are a trade-off between accuracy and speed.
- 22 June 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9529, 95291C
Feasibility test of line sensors for optical tissue thickness estimation
Purpose Line sensors are cheap, fast and have high quantum effciencies. Here, we investigate whether these sensors can replace an area image sensor for the purpose of tissue thickness measurements. Material and Methods As part of a subject study high dynamic range (HDR) images of three subjects were acquired with an area image sensor. To simulate a line sensor as realistic as possible single or multiple lines were extracted from these HDR images. Thereby, horizontally extracted lines correspond to a parallel orientation of the line sensor relative to the incident angle of a laser beam. Vertically extracted lines correspond to an orthogonal orientation. Then, optical features were determined and converted into a tissue thickness using a machine learning algorithm. Results For the tested subjects the worst root mean square error (RMSE) of the learning process was 0:385 mm. The best RMSE was 0:222 mm. For all subjects, the mean RMSE and the standard deviation of RMSE values decreases with a larger number of extracted lines. The orientation of the line sensor turned out to be important for the RMSE. Vertically oriented line sensors achieve lower RMSEs than horizontally oriented sensors because of the influence of the incident angle. Furthermore, the head-pose of the subject seems to be important for the accuracy. Conclusion Line sensors deliver comparable results to previously analysed area image sensors. Nevertheless, the scattering of the values is higher and the size and orientation of the sensor and the head-pose have an influence on the RMSE of the learning process. Therefore, line sensors are feasible for tissue thickness estimation but they are a trade-off between accuracy and speed.
- 19 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 15 (10) , 5709-5717
Data-Driven Learning for Calibrating Galvanometric Laser Scanners
State-of-the-art calibration very often constructs models motivated by a real-world device. Recently, artificial neural networks (ANNs) have been proposed as a more universal, accurate, and practical black-box approach. For a galvanometric triangulation device based on two mirrors, we embrace this proposal and set it into context with other supervised data-driven approaches: 1) ridge regression; 2) support vector regression; and 3) Gaussian processes. We show that they outperform available model-based approaches and yield similar performance compared with a memorizing lookup table calibration. The results demonstrate that an off-the-shelf usage of ANNs may run into generalization problems. Restricting the space of functions using kernel-based learning has proven to be advantageous. Finally, all approaches and distinct properties are discussed in a broader context, since each application entails differently relevant requirements for its calibration. This also holds for any calibration other than the considered triangulation device.
- 19 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 15 (10) , 5709-5717
Data-Driven Learning for Calibrating Galvanometric Laser Scanners
State-of-the-art calibration very often constructs models motivated by a real-world device. Recently, artificial neural networks (ANNs) have been proposed as a more universal, accurate, and practical black-box approach. For a galvanometric triangulation device based on two mirrors, we embrace this proposal and set it into context with other supervised data-driven approaches: 1) ridge regression; 2) support vector regression; and 3) Gaussian processes. We show that they outperform available model-based approaches and yield similar performance compared with a memorizing lookup table calibration. The results demonstrate that an off-the-shelf usage of ANNs may run into generalization problems. Restricting the space of functions using kernel-based learning has proven to be advantageous. Finally, all approaches and distinct properties are discussed in a broader context, since each application entails differently relevant requirements for its calibration. This also holds for any calibration other than the considered triangulation device.
- 16 May 2014
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 10 (4) , 363-371
Controlling motion prediction errors in radiotherapy with relevance vector machines
Robotic radiotherapy can precisely ablate moving tumors when time latencies have been compensated. Recently, relevance vector machines (RVM), a probabilistic regression technique, outperformed six other prediction algorithms for respiratory compensation. The method has the distinct advantage that each predicted point is assumed to be drawn from a normal distribution. Second-order statistics, the predicted variance, were used to control RVM prediction error during a treatment and to construct hybrid prediction algorithms. First, the duty cycle and the precision were correlated to the variance by interrupting the treatment if the variance exceeds a threshold. Second, two hybrid algorithms based on the variance were developed, one consisting of multiple RVMs (HYB(RVM)) and the other of a combination between a wavelet-based least mean square algorithm (wLMS) and a RVM (HYB(wLMS-RVM)). The variance for different motion traces was analyzed to reveal a characteristic variance pattern which gives insight in what kind of prediction errors can be controlled by the variance. Limiting the variance by a threshold resulted in an increased precision with a decreased duty cycle. All hybrid algorithms showed an increased prediction accuracy compared to using only their individual algorithms. The best hybrid algorithm, HYB(RVM), can decrease the mean RMSE over all 304 motion traces from 0.18 mm for a linear RVM to 0.17 mm. The predicted variance was shown to be an efficient metric to control prediction errors, resulting in a more robust radiotherapy treatment. The hybrid algorithm HYB(RVM) could be translated to clinical practice. It does not require further parameters, can be completely parallelised and easily further extended.
- 16 May 2014
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 10 (4) , 363-371
Controlling motion prediction errors in radiotherapy with relevance vector machines
Robotic radiotherapy can precisely ablate moving tumors when time latencies have been compensated. Recently, relevance vector machines (RVM), a probabilistic regression technique, outperformed six other prediction algorithms for respiratory compensation. The method has the distinct advantage that each predicted point is assumed to be drawn from a normal distribution. Second-order statistics, the predicted variance, were used to control RVM prediction error during a treatment and to construct hybrid prediction algorithms. First, the duty cycle and the precision were correlated to the variance by interrupting the treatment if the variance exceeds a threshold. Second, two hybrid algorithms based on the variance were developed, one consisting of multiple RVMs (HYB(RVM)) and the other of a combination between a wavelet-based least mean square algorithm (wLMS) and a RVM (HYB(wLMS-RVM)). The variance for different motion traces was analyzed to reveal a characteristic variance pattern which gives insight in what kind of prediction errors can be controlled by the variance. Limiting the variance by a threshold resulted in an increased precision with a decreased duty cycle. All hybrid algorithms showed an increased prediction accuracy compared to using only their individual algorithms. The best hybrid algorithm, HYB(RVM), can decrease the mean RMSE over all 304 motion traces from 0.18 mm for a linear RVM to 0.17 mm. The predicted variance was shown to be an efficient metric to control prediction errors, resulting in a more robust radiotherapy treatment. The hybrid algorithm HYB(RVM) could be translated to clinical practice. It does not require further parameters, can be completely parallelised and easily further extended.
- Open Access
- 18 September 2013
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 10 (5) , 056020
Hidden Markov model and support vector machine based decoding of finger movements using electrocorticography
Support vector machines (SVM) have developed into a gold standard for accurate classification in brain-computer interfaces (BCI). The choice of the most appropriate classifier for a particular application depends on several characteristics in addition to decoding accuracy. Here we investigate the implementation of hidden Markov models (HMM) for online BCIs and discuss strategies to improve their performance. We compare the SVM, serving as a reference, and HMMs for classifying discrete finger movements obtained from electrocorticograms of four subjects performing a finger tapping experiment. The classifier decisions are based on a subset of low-frequency time domain and high gamma oscillation features. We show that decoding optimization between the two approaches is due to the way features are extracted and selected and less dependent on the classifier. An additional gain in HMM performance of up to 6% was obtained by introducing model constraints. Comparable accuracies of up to 90% were achieved with both SVM and HMM with the high gamma cortical response providing the most important decoding information for both techniques. We discuss technical HMM characteristics and adaptations in the context of the presented data as well as for general BCI applications. Our findings suggest that HMMs and their characteristics are promising for efficient online BCIs.
- 18 September 2013
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 10 (5) , 056020
Open AccessHidden Markov model and support vector machine based decoding of finger movements using electrocorticography
Support vector machines (SVM) have developed into a gold standard for accurate classification in brain-computer interfaces (BCI). The choice of the most appropriate classifier for a particular application depends on several characteristics in addition to decoding accuracy. Here we investigate the implementation of hidden Markov models (HMM) for online BCIs and discuss strategies to improve their performance. We compare the SVM, serving as a reference, and HMMs for classifying discrete finger movements obtained from electrocorticograms of four subjects performing a finger tapping experiment. The classifier decisions are based on a subset of low-frequency time domain and high gamma oscillation features. We show that decoding optimization between the two approaches is due to the way features are extracted and selected and less dependent on the classifier. An additional gain in HMM performance of up to 6% was obtained by introducing model constraints. Comparable accuracies of up to 90% were achieved with both SVM and HMM with the high gamma cortical response providing the most important decoding information for both techniques. We discuss technical HMM characteristics and adaptations in the context of the presented data as well as for general BCI applications. Our findings suggest that HMMs and their characteristics are promising for efficient online BCIs.