Normal Values and Patterns of Normality and Physiological Variability of Mitral and Tricuspid Inflow Pulsed Doppler in Healthy Children
Authors:
Open Access
- 11 February 2022
- journal article
- research article
- Published by MDPI AG in Healthcare
- Vol. 10 (2) , 355
Abstract
Background: While mitral (MV) and tricuspid valve (TV) pulsed Doppler velocities and derived gradients are commonly evaluated, data on normal pediatric values are limited. This study aimed to evaluate the normal values and physiological variability for MV and TV Doppler velocities and derived gradients in a large cohort of prospectively enrolled healthy children. Methods: The echocardiographic measurements included pulsed Doppler MV and TV E and A velocities, E deceleration times (EDT), maximal and mean gradients, and velocity time integral (VTI). Results: A total of 544 healthy subjects (median age 6.4 years, range 1 day–17.68 years) were included. MV and TV E velocity, E/A ratio, and E and A wave duration increased, while A velocity decreased with age (p < 0.001). Along with an increase in VTI, there occurred a progressive increase in maximum velocity and gradients and a decrease in mean velocities and gradients. E/A inversions were common, especially at the TV in neonates and infants. For MV, inversion in either one, two, or three consecutive beats occurred in 51.9% of neonates and 18.3% of infants, while it was rare at older ages (all p < 0.001). For TV, inversions in three consecutive beats occurred in 71.4% of neonates, while inversions in only one or two beats were more common in infants (27.3%). For TV, inversion in one or more beats, however, was not infrequent at all ages. Conclusions: We report normal values and patterns of normality and physiological variability for MV and TV inflow Doppler from a large population of healthy children.Keywords
Funding Information
- Italian Health Ministry Finalized Research Young Research Award (GR-211-02350662)
This publication has 25 references indexed in Scilit:
- Nomograms for Blood Flow and Tissue Doppler Velocities to Evaluate Diastolic Function in Children: A Critical ReviewJournal of the American Society of Echocardiography, 2012
- Developmental Control of Titin Isoform Expression and Passive Stiffness in Fetal and Neonatal MyocardiumCirculation Research, 2004
- Effects of cardiac output on Doppler transmitral and transtricuspid flow velocity patterns in very low birth weight infantsInternational Journal of Cardiology, 1996
- Effect of heart rate on left ventricular diastolic filling patterns assessed by Doppler echocardiography in normal infantsThe American Journal of Cardiology, 1995
- Role of age on transmitral flow velocity patterns in assessing left ventricular diastolic function in normal infants and childrenThe American Journal of Cardiology, 1995
- Reference values and reproducibility of Doppler echocardiography in the assessment of the tricuspid valve and right ventricular diastolic function in normal subjectsThe American Journal of Cardiology, 1991
- Doppler echocardiographic studies of diastolic ventricular filling patterns in premature infantsAmerican Heart Journal, 1988
- Effects of spontaneous respiration on diastolic left ventricular filling assessed by pulsed Doppler echocardiographyThe American Journal of Cardiology, 1988
- Cardiac tamponade and pericardial effusion: Respiratory variation in transvalvular flow velocities studied by Doppler echocardiographyJACC, 1988
- Mitral and tricuspid valve anular diameter in normal children determined by two-dimensional echocardiographyThe American Journal of Cardiology, 1985