EFEliana Franchi

Eliana Franchi

*This is an algorithmically generated author record based on publicly available information.

Eliana Franchi has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Echocardiographic Markers of Right Ventricle Diastolic Dysfunction in Neonates and Infants with Congenital Heart Disease

    by Massimiliano Cantinotti, Guglielmo Capponi, Marco Scalese, Eleonora Palladino, Raffaele Giordano, Eliana Franchi, Cecilia Viacava, Giulia Corana, Pietro Marchese, Alessandra Pizzuto, et al.

    Background: Assessing right ventricular (RV) diastolic function by echocardiography in pediatric patients remains complex, particularly in congenital heart disease (CHD) characterized by RV pressure overload. The geometric peculiarities of the RV, respiratory influences, and age-dependent maturational changes complicate interpretation of Doppler-derived indices. This study aimed to characterize tricuspid valve (TV) pulsed-wave Doppler E/A inflow patterns in infants with CHD and RV pressure overload, evaluated shortly after surgical or percutaneous intervention. Methods: Echocardiographic analysis included TV E- and A-wave velocities obtained by pulsed-wave Doppler and measurement of E-wave deceleration time (EDT). Beat-to-beat variability was quantified over three consecutive cardiac cycles. Data were compared with a large cohort of age-matched healthy children. Results: Fifty-seven infants with CHD (35 pulmonary stenosis; 22 tetralogy of Fallot), examined 12–48 h post-intervention, were compared with 134 healthy controls. CHD patients showed markedly reduced beat-to-beat variability of both E- and A-wave velocities (p < 0.001 and p = 0.007, respectively). A three-beat E/A inversion pattern—common in neonates but variable in healthy infants—was consistently observed in CHD patients (p < 0.001). A-wave velocities were significantly higher (p < 0.001), whereas E/A ratios (p < 0.001) and EDT values (p = 0.010) were significantly lower compared with controls. Conclusions: Infants with CHD and RV pressure overload exhibit a characteristic Doppler pattern consisting of E/A ratio inversion, reduced beat-to-beat variability, increased A-wave velocity, and shortened E/A ratio and EDT. These findings may serve as practical and reproducible indicators of RV diastolic dysfunction in the early post-intervention period in neonates and infants.

  • Open Access

    Lung Ultrasound Findings in Healthy Children and in Those Who Had Recent, Not Severe COVID-19 Infection

    by Massimiliano Cantinotti, Pietro Marchese, Nadia Assanta, Alessandra Pizzuto, Giulia Corana, Giuseppe Santoro, Eliana Franchi, Cecilia Viacava, Jef Van Den Eynde, Shelby Kutty, et al.

    Background: Lung ultrasound (LUS) is gaining consensus as a non-invasive diagnostic imaging method for the evaluation of pulmonary disease in children. Aim: To clarify what type of artifacts (e.g., B-lines, pleural irregularity) can be defined normal LUS findings in children and to evaluate the differences in children who did not experience COVID-19 and in those with recent, not severe, previous COVID-19. Methods: LUS was performed according to standardized protocols. Different patterns of normality were defined: pattern 1: no plural irregularity and no B-lines; pattern 2: only mild basal posterior plural irregularity and no B-lines; pattern 3: mild posterior basal/para-spine/apical pleural irregularity and no B-lines; pattern 4: like pattern 3 plus rare B-lines; pattern 5: mild, diffuse short subpleural vertical artifacts and rare B-lines; pattern 6: mild, diffuse short subpleural vertical artifacts and limited B-lines; pattern 7: like pattern 6 plus minimal subpleural atelectasis. Coalescent B-lines, consolidations, or effusion were considered pathological. Results: Overall, 459 healthy children were prospectively recruited (mean age 10.564 ± 3.839 years). Children were divided into two groups: group 1 (n = 336), those who had not had COVID-19 infection, and group 2 (n = 123), those who experienced COVID-19 infection. Children with previous COVID-19 had higher values of LUS score than those who had not (p = 0.0002). Children with asymptomatic COVID-19 had similar LUS score as those who did not have infections (p > 0.05), while those who had symptoms showed higher LUS score than those who had not shown symptoms (p = 0.0228). Conclusions: We report the pattern of normality for LUS examination in children. We also showed that otherwise healthy children who recovered from COVID-19 and even those who were mildly symptomatic had more “physiological” artifacts at LUS examinations.


  • Open Access

    Atrial Function Impairments after Pediatric Cardiac Surgery Evaluated by STE Analysis

    by Massimiliano Cantinotti, Pietro Marchese, Marco Scalese, Eliana Franchi, Nadia Assanta, Martin Koestenberger, Alessandra Pizzuto, Vitali Pak, Giuseppe Santoro, Vivek Jani, et al.

    Background: Applications of atrial speckle tracking echocardiography (STE) strain (ε) analysis in pediatric cardiac surgery have been limited. This study aims to evaluate the feasibility of atrial STE ε analysis and the progression of atrial ε values as a function of post-operative time in children after pediatric cardiac surgery. Methods: 131 children (mean 1.69 ± 2.98; range 0.01–15.16 years) undergoing cardiac surgery were prospectively enrolled. Echocardiographic examinations were performed pre-operatively and at 3 different post-operative intervals: Time 1 (24–36 h), Time 2 (3–5 days), Time 3 (>5 days, before discharging). The right and left atrium longitudinal systolic contractile (Ct), Conduit (Cd), and Reservoir (R) ε were evaluated with a novel atrial specific software with both P- and R-Gating methods. One hundred and thirty-one age-matched normal subjects (mean 1.7 ± 3.2 years) were included as controls. Results: In all, 309 examinations were performed over the post-operative times. For each post-operative interval, all STE atrial ε parameters assessed were significantly lower compared to controls (all p < 0.0001). The lowest atrial ε values were found at Time 1, with only partial recovery thereafter (p from 0.02 to 0.04). All atrial ε values at discharge were decreased compared to the controls (all p < 0.0001). Significant correlations of the atrial ε values with cardio-pulmonary-bypass time, left and right ventricular ε values (p < 0.05), and ejection fraction (p < 0.05) were demonstrated. Conclusions: Atrial ε is highly reduced after surgery with only partial post-operative recovery in the near term. Our study additionally demonstrates that post-surgical atrial and ventricular ε responses correlated with each other.


  • Open Access

    Normal Values and Patterns of Normality and Physiological Variability of Mitral and Tricuspid Inflow Pulsed Doppler in Healthy Children

    by Massimiliano Cantinotti, Pietro Marchese, Marco Scalese, Eliana Franchi, Nadia Assanta, Martin Koestenberger, Jef Van Den Eynde, Shelby Kutty, Raffaele Giordano

    Background: While mitral (MV) and tricuspid valve (TV) pulsed Doppler velocities and derived gradients are commonly evaluated, data on normal pediatric values are limited. This study aimed to evaluate the normal values and physiological variability for MV and TV Doppler velocities and derived gradients in a large cohort of prospectively enrolled healthy children. Methods: The echocardiographic measurements included pulsed Doppler MV and TV E and A velocities, E deceleration times (EDT), maximal and mean gradients, and velocity time integral (VTI). Results: A total of 544 healthy subjects (median age 6.4 years, range 1 day–17.68 years) were included. MV and TV E velocity, E/A ratio, and E and A wave duration increased, while A velocity decreased with age (p < 0.001). Along with an increase in VTI, there occurred a progressive increase in maximum velocity and gradients and a decrease in mean velocities and gradients. E/A inversions were common, especially at the TV in neonates and infants. For MV, inversion in either one, two, or three consecutive beats occurred in 51.9% of neonates and 18.3% of infants, while it was rare at older ages (all p < 0.001). For TV, inversions in three consecutive beats occurred in 71.4% of neonates, while inversions in only one or two beats were more common in infants (27.3%). For TV, inversion in one or more beats, however, was not infrequent at all ages. Conclusions: We report normal values and patterns of normality and physiological variability for MV and TV inflow Doppler from a large population of healthy children.