The use of dual mobility cups in revision total hip arthroplasty for failed large head metal-on-metal bearings
Open Access
- 1 November 2023
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 48 (3) , 719-727
Abstract
Purpose: Revision of failed large head metal-on-metal (MoM) total hip arthroplasty (THA) is a challenging procedure particularly to reconstruct acetabular bone defect due to osteolysis and to achieve hip stability due to soft tissue damages, both potentially caused by adverse reaction to metal debris (ARMD). This study aimed to evaluate the outcome of dual mobility cup (DMC) constructs in revision THA for failed large head MoM bearings with a special attention to the occurrence of dislocation or re-revision. Methods: Between 2015 and 2019, 57 patients (64 THAs, 41 men, mean age = 65 ± 10 years) underwent revision for MoM THA with the use of DMC were prospectively included in our total joint registry. Mean time to revision was 11 ± 2.5 years. The causes for revision were adverse reaction to metal debris (ARMD) in 49 THAs (76%), painful hip with elevated blood cobalt-chromium ions in seven (11%), and acetabular aseptic loosening in eight (13%). The revision was complete in 22 THAs (34%) and acetabular only in 42 (66%). Clinical and radiographic outcomes, complications, and re-revisions were evaluated at most recent follow-up. Results: At mean follow-up of six ± 1.5 years, the pre- to postoperative Harris Hip Score improved from 74 ± 19 to 92 ± 4 (p = 0.004). Complications occurred in 11 cases (17%): five dislocations (8%), three periprosthetic infections (5%), two aseptic loosening of the acetabular component (3%), and two periprosthetic fractures (3%). Re-revision was required in six cases (9%). Conclusion: The use of DMC is a reliable option to prevent instability and ensure a stable acetabular reconstruction in revision THA for failed large head MoM bearings. However, dislocation after revision remains a concern, particularly in cases of severe soft tissue damage related to ARMD.Keywords
Funding Information
- University of Lausanne
This publication has 34 references indexed in Scilit:
- Poor Short Term Outcome with a Metal-On-Metal Total Hip ArthroplastyThe Journal of Arthroplasty, 2013
- Revision of metal-on-metal hip arthroplasty in a tertiary centerActa Orthopaedica, 2013
- High Complication Rate After Revision of Large-head Metal-on-metal Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2013
- Intraprosthetic Dislocation: A Specific Complication of the Dual-mobility SystemClinical Orthopaedics and Related Research, 2013
- Failure rates of metal-on-metal hip resurfacings: analysis of data from the National Joint Registry for England and WalesThe Lancet, 2012
- Five-Year Results of the ASR XL Acetabular System and the ASR Hip Resurfacing SystemJournal of Bone and Joint Surgery, 2011
- The risk of peri-prosthetic fracture after primary and revision total hip and knee replacementThe Journal of Bone and Joint Surgery. British volume, 2011
- Grading the severity of soft tissue changes associated with metal-on-metal hip replacements: reliability of an MR grading systemSkeletal Radiology, 2010
- Hip resurfacings revised for inflammatory pseudotumour have a poor outcomeThe Journal of Bone and Joint Surgery. British volume, 2009
- The Epidemiology of Bearing Surface Usage in Total Hip Arthroplasty in the United StatesJournal of Bone and Joint Surgery, 2009