Demonstration of momentum cooling to enhance the potential of cancer treatment with proton therapy
Open Access
- 3 July 2023
- journal article
- research article
- Published by Springer Nature in Nature Physics
- Vol. 19 (10) , 1437-1444
Abstract
In recent years, there has been a considerable push towards ultrahigh dose rates in proton therapy to effectively utilize motion mitigation strategies and potentially increase the sparing of healthy tissue through the so-called FLASH effect. However, in cyclotron-based proton therapy facilities, it is difficult to reach ultrahigh dose rates for low-energy beams. The main reason for this lies in the large momentum spread that such beams have after reducing their energy to levels required for proton therapy, incurring large losses in conventionally used momentum or energy selection slits. Here we propose momentum cooling by using a wedge in the energy selection system (instead of a slit) to reduce the momentum spread of the beam without introducing substantial beam losses. We demonstrate this concept in our eye treatment beamline and obtain a factor of two higher transmission, which could eventually halve the treatment delivery time. Furthermore, we show that with a gantry design incorporating this feature, we can achieve almost a factor of 100 higher transmission for a 70 MeV beam compared with conventional cyclotron-based facilities. This concept could enhance the potential of proton therapy by opening up possibilities of treating new indications and reducing the cost.Keywords
This publication has 38 references indexed in Scilit:
- A dosimetric comparison of proton and intensity modulated radiation therapy in pediatric rhabdomyosarcoma patients enrolled on a prospective phase II proton studyRadiotherapy and Oncology, 2014
- Geant4 simulations of proton beam transport through a carbon or beryllium degrader and following a beam linePhysics in Medicine & Biology, 2009
- Breathing interplay effects during proton beam scanning: simulation and statistical analysisPhysics in Medicine & Biology, 2009
- Quantification of interplay effects of scanned particle beams and moving targetsPhysics in Medicine & Biology, 2008
- The PSI Gantry 2: a second generation proton scanning gantryZeitschrift für Medizinische Physik, 2004
- Energy degrader optimization for medical beam linesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- A compact ridge filter for spread out Bragg peak production in pulsed proton clinical beamsMedical Physics, 2001
- Multi‐layer energy filter for realizing conformal irradiation in charged particle therapyMedical Physics, 2000
- The 200‐MeV proton therapy project at the Paul Scherrer Institute: Conceptual design and practical realizationMedical Physics, 1995
- Effects of respiratory motion on dose uniformity with a charged particle scanning methodPhysics in Medicine & Biology, 1992