Safety of intracranial electrodes in an MRI environment: a technical report
Open Access
- 11 March 2024
- journal article
- research article
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 71 (3) , 461-473
Abstract
Introduction: Intracranial electroencephalography (iEEG) involves placing intracranial electrodes to localise seizures in patients with medically refractory epilepsy. While magnetic resonance imaging (MRI) enables visualisation of electrodes within patient‐specific anatomy, the safety of these electrodes must be confirmed prior to routine clinical utilisation. Therefore, the purpose of this study was to evaluate the safety of iEEG electrodes from a particular manufacturer in a 3.0‐Tesla (3.0T) MRI environment.Methods: Measurements of magnetically induced displacement force and torque were determined for each of the 10 test articles using standardised techniques. Test articles were subsequently evaluated for radiofrequency‐induced heating using a Perspex phantom in both open and ‘fault’ conditions. Additionally, we assessed radiofrequency (RF)‐induced heating with all test articles placed into the phantom simultaneously to simulate an implantation, again in both open and ‘fault’ conditions. Finally, each test article was evaluated for MRI artefacts.Results: The magnetically induced displacement force was found to be less than the force on the article due to gravity for all test articles. Similarly, the maximum magnetically induced torque was less than the worst‐case torque due to gravity for all test articles apart from the 8‐contact strip – for which it was 11% greater – and the depthalon cap. The maximum temperature change for any portion of any test article assessed individually was 1.7°C, or 1.2°C for any device component meant to be implanted intracranially. In the implantation configuration, the maximum recorded temperature change was 0.7°C.Conclusions: MRI may be safely performed for localising iEEG electrodes at 3.0T under certain conditions.Keywords
This publication has 20 references indexed in Scilit:
- Clinical safety of intracranial EEG electrodes in MRI at 1.5 T and 3 T: a single-center experience and literature reviewNeuroradiology, 2021
- A phantom and animal study of temperature changes during fMRI with intracerebral depth electrodesEpilepsy Research, 2014
- CEM43°C thermal dose thresholds: a potential guide for magnetic resonance radiofrequency exposure levels?European Radiology, 2013
- Feasibility of simultaneous intracranial EEG-fMRI in humans: A safety studyNeuroImage, 2010
- Safety of localizing epilepsy monitoring intracranial electroencephalograph electrodes using MRI: Radiofrequency‐induced heatingJournal of Magnetic Resonance Imaging, 2008
- MR heating tests of MR critical implantsJournal of Magnetic Resonance Imaging, 2007
- Variability in RF‐induced heating of a deep brain stimulation implant across MR systemsJournal of Magnetic Resonance Imaging, 2006
- Evaluation of specific absorption rate as a dosimeter of MRI‐related implant heatingJournal of Magnetic Resonance Imaging, 2004
- Intracranial EEG and human brain mappingJournal of Physiology-Paris, 2003
- Neurostimulation systems for deep brain stimulation: In vitro evaluation of magnetic resonance imaging–related heating at 1.5 teslaJournal of Magnetic Resonance Imaging, 2002