Yarema Bezchlibnyk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yarema Bezchlibnyk has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Vishal Bharmauria
The Tampa Human Neurophysiology Lab, Department of Neurosurgery, Brain and Spine Morsani College of Medicine, University of South Florida Florida USA
4 shared publications - Brian Dalm
Department of Neurosurgery Ohio State University Columbus Ohio USA
3 shared publications - Keaton Piper
Department of Neurosurgery, University of South Florida, Tampa, Florida; and
3 shared publications - Alexander Laurence Green
University of Oxford
2 shared publications - Amir Hossein Ghaderi
Centre for Vision Research, and Vision: Science to Applications Program, York University, Canada
2 shared publications Andres M. Lozano
Division of Neurosurgery, Department of Surgery University of Toronto Toronto Ontario Canada
2 shared publications
Latest Publications
- Open Access
- 16 July 2026
- Published by Wiley in European Journal of Neuroscience
- Vol. 64 (2) , e70628
High‐Frequency Spinal Cord Stimulation Modifies Tibial Nerve‐Stimulation‐Evoked Cortical Theta‐Gamma Coupling in Sheep Cortex
Pain management strategies have progressed beyond traditional pharmacologic and physical interventions, integrating advanced neuromodulation techniques such as deep brain stimulation, peripheral nerve stimulation, and high‐frequency spinal cord stimulation (hSCS). Despite its clinical efficacy, the supraspinal mechanisms underlying hSCS remain poorly understood. Prior work in sheep demonstrated that hSCS modulates gamma (γ) band (70–150 Hz) activity in the primary somatosensory and association cortices, implicating cortical involvement in pain modulation. Given the interaction between low‐ and high‐oscillations, we hypothesized that hSCS modulates γ activity in a region‐ and time‐dependent manner through specific coupling with theta rhythms (θ, 4–8 Hz). To test this, we quantified θ–γ phase‐amplitude coupling (PAC) during tibial nerve stimulation (TNS) before (TNS 0 ) and after (TNS 1 ) hSCS to assess cortical processing of TNS‐evoked activity, while recording cortical (association and somatosensory cortices) neural activity using 96‐channel subdural electrocorticography (ECoG). We then computed the corresponding modulation index (MI) to quantify PAC strength. While the preferred θ phase of γ activity remained consistent across conditions in both cortical areas, θ‐γ coupling was more robust and stable in the association than the somatosensory cortex. However, MI increased significantly post‐hSCS in both cortices, indicating enhanced θ‐γ coupling during TNS 1 . Temporally, both cortices showed distinct response patterns: the somatosensory cortex exhibited strongest coupling increase early post‐hSCS, followed by a progressive decline, whereas the association cortex showed a more delayed and temporally distributed enhancement. These findings indicate that hSCS modulates cortical cross‐frequency interactions during TNS‐evoked sensory processing, wherein somatosensory and association cortices show distinct temporal coupling dynamics that may contribute to supraspinal mechanisms of pain modulation.
- 16 July 2026
- Published by Wiley in European Journal of Neuroscience
- Vol. 64 (2) , e70628
Open AccessHigh‐Frequency Spinal Cord Stimulation Modifies Tibial Nerve‐Stimulation‐Evoked Cortical Theta‐Gamma Coupling in Sheep Cortex
Pain management strategies have progressed beyond traditional pharmacologic and physical interventions, integrating advanced neuromodulation techniques such as deep brain stimulation, peripheral nerve stimulation, and high‐frequency spinal cord stimulation (hSCS). Despite its clinical efficacy, the supraspinal mechanisms underlying hSCS remain poorly understood. Prior work in sheep demonstrated that hSCS modulates gamma (γ) band (70–150 Hz) activity in the primary somatosensory and association cortices, implicating cortical involvement in pain modulation. Given the interaction between low‐ and high‐oscillations, we hypothesized that hSCS modulates γ activity in a region‐ and time‐dependent manner through specific coupling with theta rhythms (θ, 4–8 Hz). To test this, we quantified θ–γ phase‐amplitude coupling (PAC) during tibial nerve stimulation (TNS) before (TNS 0 ) and after (TNS 1 ) hSCS to assess cortical processing of TNS‐evoked activity, while recording cortical (association and somatosensory cortices) neural activity using 96‐channel subdural electrocorticography (ECoG). We then computed the corresponding modulation index (MI) to quantify PAC strength. While the preferred θ phase of γ activity remained consistent across conditions in both cortical areas, θ‐γ coupling was more robust and stable in the association than the somatosensory cortex. However, MI increased significantly post‐hSCS in both cortices, indicating enhanced θ‐γ coupling during TNS 1 . Temporally, both cortices showed distinct response patterns: the somatosensory cortex exhibited strongest coupling increase early post‐hSCS, followed by a progressive decline, whereas the association cortex showed a more delayed and temporally distributed enhancement. These findings indicate that hSCS modulates cortical cross‐frequency interactions during TNS‐evoked sensory processing, wherein somatosensory and association cortices show distinct temporal coupling dynamics that may contribute to supraspinal mechanisms of pain modulation.
- Open Access
High-Frequency Spinal Cord Stimulation Reorganizes Cortical Cross-Frequency Coupling in a Region- and Time-Dependent Manner
Pain management strategies have progressed beyond traditional pharmacologic and physical interventions, integrating advanced neuromodulation techniques such as deep brain stimulation, peripheral nerve stimulation, and high-frequency spinal cord stimulation (hSCS). Despite its clinical efficacy, the supraspinal mechanisms underlying hSCS remain poorly understood. Prior work in sheep demonstrated that hSCS modulates gamma band (70–150 Hz) activity in the primary somatosensory and association cortices, implicating cortical involvement in pain modulation. Given, the interaction between low and high oscillations, we hypothesized that hSCS modulates gamma activity in a region- and time-dependent manner through specific coupling with theta rhythms (4–8 Hz). Using 96-channel subdural electrocorticography (ECoG), we computed theta–gamma phase–amplitude coupling (PAC) and the corresponding modulation index (MI) to quantify the effects of hSCS. While the preferred theta phase of gamma activity remained consistent across conditions and regions, MI increased significantly post-stimulation, most prominently in the association cortex, where robust theta-gamma phase locking was observed. In contrast, the somatosensory cortex exhibited weaker and more variable locking. Temporally, both cortices demonstrated an early, rapid increase in MI post-hSCS, accompanied by a shift (association) and attenuation (somatosensory) of the secondary peak. These findings reveal distinct regional and temporal dynamics in PAC following hSCS and suggest complementary roles of somatosensory and association cortices in processing neuromodulatory input. hSCS appears to reorganize cortical cross-frequency interactions, supporting its role in reorganizing functional network dynamics relevant to sensory processing and the subjective pain experience.
Open AccessHigh-Frequency Spinal Cord Stimulation Reorganizes Cortical Cross-Frequency Coupling in a Region- and Time-Dependent Manner
Pain management strategies have progressed beyond traditional pharmacologic and physical interventions, integrating advanced neuromodulation techniques such as deep brain stimulation, peripheral nerve stimulation, and high-frequency spinal cord stimulation (hSCS). Despite its clinical efficacy, the supraspinal mechanisms underlying hSCS remain poorly understood. Prior work in sheep demonstrated that hSCS modulates gamma band (70–150 Hz) activity in the primary somatosensory and association cortices, implicating cortical involvement in pain modulation. Given, the interaction between low and high oscillations, we hypothesized that hSCS modulates gamma activity in a region- and time-dependent manner through specific coupling with theta rhythms (4–8 Hz). Using 96-channel subdural electrocorticography (ECoG), we computed theta–gamma phase–amplitude coupling (PAC) and the corresponding modulation index (MI) to quantify the effects of hSCS. While the preferred theta phase of gamma activity remained consistent across conditions and regions, MI increased significantly post-stimulation, most prominently in the association cortex, where robust theta-gamma phase locking was observed. In contrast, the somatosensory cortex exhibited weaker and more variable locking. Temporally, both cortices demonstrated an early, rapid increase in MI post-hSCS, accompanied by a shift (association) and attenuation (somatosensory) of the secondary peak. These findings reveal distinct regional and temporal dynamics in PAC following hSCS and suggest complementary roles of somatosensory and association cortices in processing neuromodulatory input. hSCS appears to reorganize cortical cross-frequency interactions, supporting its role in reorganizing functional network dynamics relevant to sensory processing and the subjective pain experience.
- 15 July 2025
- Published by Elsevier in The Journal of Pain
- Vol. 34, 105493
Neurophysiological effects of high-frequency spinal cord stimulation on cortico-sensory areas in large ovine animal model
- 15 July 2025
- Published by Elsevier in The Journal of Pain
- Vol. 34, 105493
Neurophysiological effects of high-frequency spinal cord stimulation on cortico-sensory areas in large ovine animal model
Neuropsychological outcomes of hippocampus‐sparing anterior temporal lobectomy versus stereotactic laser amygdalohippocampectomy in language‐dominant temporal lobe epilepsy
Objective: Postoperative neuropsychological deficits pose a significant challenge for temporal lobe epilepsy (TLE) surgery, particularly in the language‐dominant hemisphere. Two surgical approaches have been suggested to mitigate such adverse outcomes: stereotactic laser amygdalohippocampectomy (SLAH) and hippocampus‐sparing anterior temporal lobectomy (HSATL). This retrospective cohort study compares the seizure control and neuropsychological outcomes of HSATL and SLAH in language‐dominant TLE. Methods: A retrospective cohort study compared 27 patients (nine male, mean age = 35.8 years) with drug‐resistant TLE and normal imaging localized to the language‐dominant left temporal lobe, undergoing either HSATL ( n = 22) or SLAH ( n = 5) between 2014 and 2021. Comprehensive pre‐ and ≥1‐year postoperative neuropsychological testing and imaging were performed, with seizure outcomes tracked for at least 1 year postoperatively. However, to assess the impact of mesial temporal sclerosis (MTS) on SLAH outcomes, we included seven additional patients with MTS who underwent SLAH in a secondary analysis. Results: HSATL led to significant declines in logical memory ( p = .04) despite sparing the hippocampus, which were not seen following SLAH in patients regardless of MTS status. SLAH trended toward improved semantic fluency, immediate verbal memory, and executive function despite hippocampal ablation. Including both MTS(+) and MTS(−) patients, there was a significant decline in letter fluency following SLAH (.04), with subgroup analyses demonstrating significantly greater declines in MTS(+) patients undergoing SLAH (.02). Additionally, 100% of patients undergoing SLAH achieved seizure freedom versus 72.7% following HSATL ( p = .046, including MTS[+] patients) at last follow‐up. Significance: In language‐dominant TLE, SLAH demonstrated comparable seizure outcomes and superior verbal memory retention compared to HSATL, albeit with greater letter fluency impairment. Preliminary findings challenge prioritizing hippocampal preservation for verbal memory function, suggesting potential cognitive advantages with SLAH specifically targeting mesial structures while maximally preserving cortical structures and white matter tracts critical for language networks. However, this intervention may negatively impact letter fluency, suggesting careful preoperative screening and discussion.
Neuropsychological outcomes of hippocampus‐sparing anterior temporal lobectomy versus stereotactic laser amygdalohippocampectomy in language‐dominant temporal lobe epilepsy
Objective: Postoperative neuropsychological deficits pose a significant challenge for temporal lobe epilepsy (TLE) surgery, particularly in the language‐dominant hemisphere. Two surgical approaches have been suggested to mitigate such adverse outcomes: stereotactic laser amygdalohippocampectomy (SLAH) and hippocampus‐sparing anterior temporal lobectomy (HSATL). This retrospective cohort study compares the seizure control and neuropsychological outcomes of HSATL and SLAH in language‐dominant TLE. Methods: A retrospective cohort study compared 27 patients (nine male, mean age = 35.8 years) with drug‐resistant TLE and normal imaging localized to the language‐dominant left temporal lobe, undergoing either HSATL ( n = 22) or SLAH ( n = 5) between 2014 and 2021. Comprehensive pre‐ and ≥1‐year postoperative neuropsychological testing and imaging were performed, with seizure outcomes tracked for at least 1 year postoperatively. However, to assess the impact of mesial temporal sclerosis (MTS) on SLAH outcomes, we included seven additional patients with MTS who underwent SLAH in a secondary analysis. Results: HSATL led to significant declines in logical memory ( p = .04) despite sparing the hippocampus, which were not seen following SLAH in patients regardless of MTS status. SLAH trended toward improved semantic fluency, immediate verbal memory, and executive function despite hippocampal ablation. Including both MTS(+) and MTS(−) patients, there was a significant decline in letter fluency following SLAH (.04), with subgroup analyses demonstrating significantly greater declines in MTS(+) patients undergoing SLAH (.02). Additionally, 100% of patients undergoing SLAH achieved seizure freedom versus 72.7% following HSATL ( p = .046, including MTS[+] patients) at last follow‐up. Significance: In language‐dominant TLE, SLAH demonstrated comparable seizure outcomes and superior verbal memory retention compared to HSATL, albeit with greater letter fluency impairment. Preliminary findings challenge prioritizing hippocampal preservation for verbal memory function, suggesting potential cognitive advantages with SLAH specifically targeting mesial structures while maximally preserving cortical structures and white matter tracts critical for language networks. However, this intervention may negatively impact letter fluency, suggesting careful preoperative screening and discussion.
- Open Access
- 16 October 2024
- Published by IntechOpen
Neurostimulation in Neuro-Ophthalmology: Mechanisms and Therapeutic Potential
Visual processing constitutes a substantial portion of cognitive, executive, and sensorimotor functions of the brain. Understandably, damage to visual areas and pathways results in various impairments. Neuro-ophthalmology addresses these complexities, yet traditional management approaches often have limited efficacy and undesirable side effects. In recent years, neurostimulation has emerged as a promising alternative, offering strong therapeutic benefits with minimal adverse effects. While extensively explored in neurological and psychiatric disorders, its application in ophthalmology remains relatively underexplored. This chapter navigates recent advancements in neurostimulation techniques, focusing on their potential in treating neuro-ophthalmic illnesses. We begin with an introduction to the visual system and then cover major neuro-ophthalmologic illnesses and related stimulation principles while also describing associated neurochemical and neuroplastic changes. Two major types of neurostimulation modalities in ophthalmology are discussed—invasive and non-invasive—highlighting their mechanisms and therapeutic potentials. Finally, we address current challenges, gaps, and prospects in neurostimulation research in ophthalmology in managing neuro-ophthalmic disorders.
- 16 October 2024
- Published by IntechOpen
Open AccessNeurostimulation in Neuro-Ophthalmology: Mechanisms and Therapeutic Potential
Visual processing constitutes a substantial portion of cognitive, executive, and sensorimotor functions of the brain. Understandably, damage to visual areas and pathways results in various impairments. Neuro-ophthalmology addresses these complexities, yet traditional management approaches often have limited efficacy and undesirable side effects. In recent years, neurostimulation has emerged as a promising alternative, offering strong therapeutic benefits with minimal adverse effects. While extensively explored in neurological and psychiatric disorders, its application in ophthalmology remains relatively underexplored. This chapter navigates recent advancements in neurostimulation techniques, focusing on their potential in treating neuro-ophthalmic illnesses. We begin with an introduction to the visual system and then cover major neuro-ophthalmologic illnesses and related stimulation principles while also describing associated neurochemical and neuroplastic changes. Two major types of neurostimulation modalities in ophthalmology are discussed—invasive and non-invasive—highlighting their mechanisms and therapeutic potentials. Finally, we address current challenges, gaps, and prospects in neurostimulation research in ophthalmology in managing neuro-ophthalmic disorders.
- Open Access
- 11 March 2024
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 71 (3) , 461-473
Safety of intracranial electrodes in an MRI environment: a technical report
Introduction: Intracranial electroencephalography (iEEG) involves placing intracranial electrodes to localise seizures in patients with medically refractory epilepsy. While magnetic resonance imaging (MRI) enables visualisation of electrodes within patient‐specific anatomy, the safety of these electrodes must be confirmed prior to routine clinical utilisation. Therefore, the purpose of this study was to evaluate the safety of iEEG electrodes from a particular manufacturer in a 3.0‐Tesla (3.0T) MRI environment.Methods: Measurements of magnetically induced displacement force and torque were determined for each of the 10 test articles using standardised techniques. Test articles were subsequently evaluated for radiofrequency‐induced heating using a Perspex phantom in both open and ‘fault’ conditions. Additionally, we assessed radiofrequency (RF)‐induced heating with all test articles placed into the phantom simultaneously to simulate an implantation, again in both open and ‘fault’ conditions. Finally, each test article was evaluated for MRI artefacts.Results: The magnetically induced displacement force was found to be less than the force on the article due to gravity for all test articles. Similarly, the maximum magnetically induced torque was less than the worst‐case torque due to gravity for all test articles apart from the 8‐contact strip – for which it was 11% greater – and the depthalon cap. The maximum temperature change for any portion of any test article assessed individually was 1.7°C, or 1.2°C for any device component meant to be implanted intracranially. In the implantation configuration, the maximum recorded temperature change was 0.7°C.Conclusions: MRI may be safely performed for localising iEEG electrodes at 3.0T under certain conditions.
- 11 March 2024
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 71 (3) , 461-473
Open AccessSafety of intracranial electrodes in an MRI environment: a technical report
Introduction: Intracranial electroencephalography (iEEG) involves placing intracranial electrodes to localise seizures in patients with medically refractory epilepsy. While magnetic resonance imaging (MRI) enables visualisation of electrodes within patient‐specific anatomy, the safety of these electrodes must be confirmed prior to routine clinical utilisation. Therefore, the purpose of this study was to evaluate the safety of iEEG electrodes from a particular manufacturer in a 3.0‐Tesla (3.0T) MRI environment.Methods: Measurements of magnetically induced displacement force and torque were determined for each of the 10 test articles using standardised techniques. Test articles were subsequently evaluated for radiofrequency‐induced heating using a Perspex phantom in both open and ‘fault’ conditions. Additionally, we assessed radiofrequency (RF)‐induced heating with all test articles placed into the phantom simultaneously to simulate an implantation, again in both open and ‘fault’ conditions. Finally, each test article was evaluated for MRI artefacts.Results: The magnetically induced displacement force was found to be less than the force on the article due to gravity for all test articles. Similarly, the maximum magnetically induced torque was less than the worst‐case torque due to gravity for all test articles apart from the 8‐contact strip – for which it was 11% greater – and the depthalon cap. The maximum temperature change for any portion of any test article assessed individually was 1.7°C, or 1.2°C for any device component meant to be implanted intracranially. In the implantation configuration, the maximum recorded temperature change was 0.7°C.Conclusions: MRI may be safely performed for localising iEEG electrodes at 3.0T under certain conditions.
- Open Access
- 15 January 2024
- Published by Frontiers Media SA in Frontiers in Network Physiology
- Vol. 4, 1342161
No change in network connectivity measurements between separate rsfMRI acquisition times
The role of resting state functional MRI (rsfMRI) is increasing in the field of epilepsy surgery because it is possible to interpolate network connectivity patterns across the brain with a high degree of spatial resolution. Prior studies have shown that by rsfMRI with scalp electroencephalography (EEG), an epileptogenic network can be modeled and visualized with characteristic patterns of connectivity that are relevant to both seizure-related and neuropsychological outcomes after surgery. The aim of this study is to show that a 5-min acquisition time provides reproducible results related to the relevant connectivity metrics when compared to a separately acquired 5-min scan. Fourteen separate rsfMRI sessions from ten different patients were used for comparison, comprised of patients with temporal lobe epilepsy both pre- and post-operation. Results showed that there was no significant difference in any of the connectivity metrics when comparing both 5-min scans to each other. These data support the continued use of a 5-min scan for epileptogenic network modeling in future studies because the inter-scan variability is sufficiently low as not to alter the output metrics characterizing the network connectivity.
- 15 January 2024
- Published by Frontiers Media SA in Frontiers in Network Physiology
- Vol. 4, 1342161
Open AccessNo change in network connectivity measurements between separate rsfMRI acquisition times
The role of resting state functional MRI (rsfMRI) is increasing in the field of epilepsy surgery because it is possible to interpolate network connectivity patterns across the brain with a high degree of spatial resolution. Prior studies have shown that by rsfMRI with scalp electroencephalography (EEG), an epileptogenic network can be modeled and visualized with characteristic patterns of connectivity that are relevant to both seizure-related and neuropsychological outcomes after surgery. The aim of this study is to show that a 5-min acquisition time provides reproducible results related to the relevant connectivity metrics when compared to a separately acquired 5-min scan. Fourteen separate rsfMRI sessions from ten different patients were used for comparison, comprised of patients with temporal lobe epilepsy both pre- and post-operation. Results showed that there was no significant difference in any of the connectivity metrics when comparing both 5-min scans to each other. These data support the continued use of a 5-min scan for epileptogenic network modeling in future studies because the inter-scan variability is sufficiently low as not to alter the output metrics characterizing the network connectivity.
- 1 November 2023
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 26 (3) , 279-285
Anatomic Variations of Foramen Ovale as a Predictor of Successful Cannulation in Percutaneous Trigeminal Rhizotomies
BACKGROUND AND OBJECTIVES: Percutaneous trigeminal rhizotomies are common treatment modalities for medically refractory trigeminal neuralgia (TN). Failure of these procedures is frequently due to surgical inability to cannulate the foramen ovale (FO) and is thought to be due to variations in anatomy. The purpose of this study is to characterize the relationships between anatomic features surrounding FO and investigate the association between anatomic morphology and successful cannulation of FO in patients undergoing percutaneous trigeminal rhizotomy. METHODS: A retrospective analysis was conducted of all patients undergoing percutaneous trigeminal rhizotomy for TN at our academic center between January 1, 2010, and July 31, 2022. Preoperative 1-mm thin-cut computed tomography head imaging was accessed to perform measurements surrounding the FO, including inlet width, outlet width, interforaminal distance (a representation of the lateral extent of FO along the middle fossa), and sella–sphenoid angle (a representation of the coronal slope of FO). Mann–Whitney U tests assessed the difference in measurements for patients who succeeded and failed cannulation. RESULTS: Among 37 patients who met inclusion criteria, 34 (91.9%) successfully underwent cannulation. Successful cannulation was associated with larger inlet widths (median = 5.87 vs 3.67 mm, U = 6.0, P = .006), larger outlet widths (median = 7.13 vs 5.10 mm, U = 14.0, P = .040), and smaller sella–sphenoid angles (median = 52.00° vs 111.00°, U = 0.0, P < .001). Interforaminal distances were not associated with the ability to cannulate FO surgically. CONCLUSION: We have identified morphological characteristics associated with successful cannulation in percutaneous rhizotomies for TN. Preoperative imaging may optimize surgical technique and predict cannulation failure.
- 1 November 2023
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 26 (3) , 279-285
Anatomic Variations of Foramen Ovale as a Predictor of Successful Cannulation in Percutaneous Trigeminal Rhizotomies
BACKGROUND AND OBJECTIVES: Percutaneous trigeminal rhizotomies are common treatment modalities for medically refractory trigeminal neuralgia (TN). Failure of these procedures is frequently due to surgical inability to cannulate the foramen ovale (FO) and is thought to be due to variations in anatomy. The purpose of this study is to characterize the relationships between anatomic features surrounding FO and investigate the association between anatomic morphology and successful cannulation of FO in patients undergoing percutaneous trigeminal rhizotomy. METHODS: A retrospective analysis was conducted of all patients undergoing percutaneous trigeminal rhizotomy for TN at our academic center between January 1, 2010, and July 31, 2022. Preoperative 1-mm thin-cut computed tomography head imaging was accessed to perform measurements surrounding the FO, including inlet width, outlet width, interforaminal distance (a representation of the lateral extent of FO along the middle fossa), and sella–sphenoid angle (a representation of the coronal slope of FO). Mann–Whitney U tests assessed the difference in measurements for patients who succeeded and failed cannulation. RESULTS: Among 37 patients who met inclusion criteria, 34 (91.9%) successfully underwent cannulation. Successful cannulation was associated with larger inlet widths (median = 5.87 vs 3.67 mm, U = 6.0, P = .006), larger outlet widths (median = 7.13 vs 5.10 mm, U = 14.0, P = .040), and smaller sella–sphenoid angles (median = 52.00° vs 111.00°, U = 0.0, P < .001). Interforaminal distances were not associated with the ability to cannulate FO surgically. CONCLUSION: We have identified morphological characteristics associated with successful cannulation in percutaneous rhizotomies for TN. Preoperative imaging may optimize surgical technique and predict cannulation failure.
- 20 October 2023
- Published by Elsevier in World Neurosurgery
- Vol. 181, e447-e452
Does Head Positioning After Percutaneous Glycerol Rhizotomy for Trigeminal Neuralgia Matter?
- 20 October 2023
- Published by Elsevier in World Neurosurgery
- Vol. 181, e447-e452
Does Head Positioning After Percutaneous Glycerol Rhizotomy for Trigeminal Neuralgia Matter?