Repeatability (test‐retest variability) of refractive error measurement in clinical settings
Authors:
Open Access
- 30 May 2006
- journal article
- Published by Wiley in Acta Ophthalmologica Scandinavica
- Vol. 84 (4) , 532-536
Abstract
: Purpose: To estimate the repeatability of refractive error measurement (REM) in a clinical environment in cataractous, pseudophakic and healthy eyes.Methods: The refractive error of patients referred for cataract surgery or consultation measured by ophthalmic professionals was re‐examined and the measurement results were compared. A total of 99 eyes from 99 persons (41 cataractous, 36 pseudophakic and 22 healthy eyes) with visual acuity (VA) of 0.3–1.3 (logMAR 0.52 to − 0.11) were included. The differences between measurements 1 and 2 were calculated as 3‐dimensional vector values and spherical equivalents (SEs) and expressed as the coefficient of repeatability (CR). The mean time interval between the first and second examinations was 45 days.Results: The CRs for all eyes for vertical (V), torsional (T) and horizontal (H) vectors were 0.74 D, 0.34 D and 0.93 D, respectively. The CR of SE for all eyes was 0.74 D. Eyes with lower VA (0.3–0.45) had larger variability in vector and SE values but the differences between VA groups were not statistically significant. The difference in the mean defocus equivalent (DE) between measurements 1 and 2 was, however, significantly greater in the group with lower VA. In all VA groups the mean difference vector was very close to the zero vector, which means that there was no systematic difference.Conclusions: Repeatability of refractive error measurements in clinical settings has a certain degree of variability. In this series, the variability in eyes with better VA was not great and was in accordance with earlier findings in healthy eyes. Eyes with lower VA had greater variability due to greater tolerance to defocus. Thus, conclusions concerning changes in the refractive state and the need to make changes in the refractive correction of eyes with poorer vision should be made with caution.Keywords
This publication has 20 references indexed in Scilit:
- Random measurement error in visual acuity measurement in clinical settingsActa Ophthalmologica Scandinavica, 2005
- Accuracy and precision of objective refraction from wavefront aberrationsJournal of Vision, 2004
- Predicting subjective judgment of best focus with objective image quality metricsJournal of Vision, 2004
- Evaluation of the measurement of refractive error by the PowerRefractor: a remote, continuous and binocular measurement system of oculomotor functionBritish Journal of Ophthalmology, 2003
- Analyzing refractive dataJournal of Cataract & Refractive Surgery, 2002
- The mean and variance of samples of dioptric powers: the basic calculationsClinical and Experimental Optometry, 1990
- Direct, vec and other squares, and sample variance—covariance of dioptric powerOphthalmic and Physiological Optics, 1990
- Tolerance to visual defocusJournal of the Optical Society of America A, 1987
- Dioptric Power in an Off-Axis MeridianOptometry and Vision Science, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986