Comparison of multiple blood pressure frequency methods with optimum blood pressure measurement among Iranian individuals
Open Access
- 1 January 2020
- journal article
- research article
- Published by Medknow in Journal of Research in Medical Sciences
- Vol. 25 (1) , 40
Abstract
Background: Proper blood pressure (BP) measurement frequency method is less evaluated to optimize hypertension (HTN) status among different nations due to cultural patience variations. The aim of this study was to compare the first (BP1), second (BP2), and the mean of first and second (BP1,2) and all the three (BP1,2,3) with the second and third BP measurements in Iranian individuals. Materials and Methods: This cross-sectional study was done on 2264 individuals aged 18 years or more living in Isfahan city, Iran. Their BPs were assessed from right arms by the standard tools and methods after 5 min of rest in a quiet room by a trained staff. The mean second and third readings were considered as reference, and the other aforementioned variables were compared with it. Results: The mean age of total population was 40.9 ± 16.1 years (males: 52%). Men had significant higher means of systolic BP (SBP) and diastolic BP (DBP) with any measurement frequency methods than women (P < 0.001 and P = 0.009). Considerable clinical significant (≥5 mmHg) ranges were mostly observed in BP1compared with BP2,3. SBP2and DBP2indices showed insignificant differences compared with reference mean. Moreover, abnormal BP levels (≥140/90 mmHg) were mostly observed in terms of BP1measurement with no remarkable variability in BP2reading in comparison to the reference. Conclusion: Our considerable data suggested that BP2could appropriately categorize BP status similar to BP2,3and it may be rational for physicians considering this mean and excluding the first BP measurement as a sole criterion for HTN assessment in Iranian adults. Multiple researches are necessary quantifying appropriate frequencies of BP reading.Keywords
This publication has 20 references indexed in Scilit:
- Diagnostic accuracy of manual office blood pressure measurement in ambulatory hypertensive patients in KoreaThe Korean Journal of Internal Medicine, 2018
- Global, Regional, and National Burden of Cardiovascular Diseases for 10 Causes, 1990 to 2015JACC, 2017
- Prevalence of Hypertension in Low- and Middle-Income CountriesMedicine, 2015
- Diagnostic and Predictive Accuracy of Blood Pressure Screening Methods With Consideration of Rescreening Intervals: A Systematic Review for the U.S. Preventive Services Task ForceAnnals of Internal Medicine, 2015
- Comparison of the Average of Five Readings with Averages from Fewer Readings for Automated Oscillometric Blood Pressure Measurement in an Outpatient ClinicKorean Circulation Journal, 2013
- Diagnostic accuracy of home vs. ambulatory blood pressure monitoring in untreated and treated hypertensionHypertension Research, 2012
- Thirty-minute compared to standardised office blood pressure measurement in general practiceBritish Journal of General Practice, 2011
- Hypertension epidemiology and economic burden: refining risk assessment to lower costs.2009
- Economic burden of cardiovascular diseases in ChinaExpert Review of Pharmacoeconomics & Outcomes Research, 2008
- Recommendations for Blood Pressure Measurement in Humans and Experimental AnimalsCirculation, 2005