Comparison of Central Corneal Thickness Measurements Obtained by RTVue OCT, Lenstar, Sirius Topography, and Ultrasound Pachymetry in Healthy Subjects
Authors:
- 20 November 2014
- journal article
- research article
- Published by Taylor & Francis in Seminars in Ophthalmology
- Vol. 31 (5) , 467-472
Abstract
To compare central corneal thickness (CCT) measurement results obtained by RTVue OCT, Lenstar, Sirius topography, and ultrasound pachymetry (UP) (OcuScan RxP Ophthalmic Ultrasound System, Alcon Laboratories) in healthy subjects. 256 eyes of 128 healthy subjects were included in the study. CCT measurements were obtained from the eyes for each subject using the UP, Lenstar, Sirius topography, and RTVue OCT instruments. Ultrasound pachymetry measurements were performed after the eyes were anesthetized with one drop of 0.5% proparacaine hydrochloride and were performed at the same day after 15 minutes after previous measurements. Of 128 participants, 84 were male and 44 were female with a mean age of 33.15 ± 12.95 years (ranging from 18 to 75 years). The mean CCTs for UP, Lenstar, Sirius topography, and RTVue OCT were 535.60 ± 35.15 (440,00-668,00); 532.63 ± 34.44 (449,00-650,00); 526.05 ± 36.45 (314,00-640,00); 525.89 ± 33.21 (437,00-646,00) µm, respectively. The mean CCT measurements were statistically different among the three groups (p = 0.002). CCT measurements obtained using RTVue-OCT were significantly thinner than those obtained using UP (p = 0.009). Sirius CCT measurements were also thinner than UP (p = 0.011). Mean CCT measurements between UP and Lenstar were similar (p = 0.769). Measurements with Lenstar (r = 0.849), Sirius topography (r = 0.883), and RTVue OCT (0.949) were highly correlated with UP measurements. RTVue OCT and Sirius topography significantly underestimated the CCT compared with UP. Although highly correlated, the measurement values with these devices are not directly interchangeable in clinical practice.Keywords
This publication has 23 references indexed in Scilit:
- Precision of a new Scheimpflug and Placido-disk analyzer in measuring corneal thickness and agreement with ultrasound pachymetryJournal of Cataract & Refractive Surgery, 2013
- The Role of Axial Resolution of Optical Coherence Tomography on the Measurement of Corneal and Epithelial ThicknessesInvestigative Ophthalmology & Visual Science, 2013
- Comparative Study of Central Corneal Thickness Using Fourier-Domain Optical Coherence Tomography Versus Ultrasound Pachymetry in Primary Open-Angle GlaucomaCornea, 2013
- Comparison of Central Corneal Thickness Measurements With Optical Low-Coherence Reflectometry and Ultrasound Pachymetry and Reproducibility of Both DevicesCornea, 2012
- Comparison of Central Corneal Thickness and Anterior Chamber Depth Measured Using LenStar LS900, Pentacam, and Visante AS-OCTCornea, 2012
- Repeatability and Reproducibility of Biometry and Keratometry Measurements Using a Noncontact Optical Low-Coherence Reflectometer and KeratometerAmerican Journal of Ophthalmology, 2012
- Central Corneal Thickness Measurements: Using an Ultrasonic Instrument and 4 Optical InstrumentsCornea, 2011
- Laser in situ keratomileusis flap measurements: Comparison between observers and between spectral-domain and time-domain anterior segment optical coherence tomographyJournal of Cataract & Refractive Surgery, 2011
- A new non-contact optical device for ocular biometryBritish Journal of Ophthalmology, 2002
- Human Corneal Thickness and Its Impact on Intraocular Pressure MeasuresSurvey of Ophthalmology, 2000