The Norwood procedure creates a reconstructed neo-aorta to provide unobstructed systemic cardiac output for hypoplastic left heart syndrome patients. We used patient-specific computational fluid dynamics (CFD) simulations incorporating physiologic boundary conditions to quantify hemodynamics for reconstructed aortic arch geometries versus native aortic arches from a control group of single ventricle patients. We hypothesized that reconstructed arches from Norwood patients (n = 5) would experience significant differences in time-averaged wall shear stress normalized to body surface area (TAWSSnBSA), oscillatory shear index (OSI), energy efficiency (Eeff), and energy loss (EL) versus controls (n = 3). CFD simulations were conducted using 3 T cardiac magnetic resonance imaging, blood flow, and pressure data. Simulations incorporated downstream vascular resistance and compliance to replicate patient physiology. TAWSSnBSA and OSI were quantified axially and circumferentially. Global differences in Eeff and EL were compared. Significance was assessed by Mann–Whitney U test. Norwood patients had higher TAWSSnBSA distal to the transverse arch at locations of residual narrowing presenting following coarctation correction, as well as higher OSI within ascending aorta and transverse arch regions (p < 0.05). EL correlated with patient features including cardiac output (r = 0.9) and BT-shunt resistance (r = –0.63) but did not correlate with arch measurements or morphology. These results indicate reconstructed arches from Norwood patients are exposed to altered wall shear stress and energy indices linked to cellular proliferation and inefficiency in prior studies. These results may help clinicians further understand what constitutes an optimally reconstructed arch after confirmation in larger studies.Keywords
All Related Versions
This publication has 42 references indexed in Scilit:
- Effect of Virtual Aortic Arch Reconstruction After Norwood Procedure on Cardiac Function, Energy Efficiency, and Wall Shear Stress from Multiscale SimulationsCurrent Cardiovascular Imaging Reports, 2023
- The Role of Immersion for Improving Extended Reality Analysis of Personalized Flow SimulationsCardiovascular Engineering and Technology, 2022
- New imaging tools in cardiovascular medicine: computational fluid dynamics and 4D flow MRIGeneral Thoracic and Cardiovascular Surgery, 2017
- Toward translating near-infrared spectroscopy oxygen saturation data for the non-invasive prediction of spatial and temporal hemodynamics during exerciseBiomechanics and Modeling in Mechanobiology, 2016
- Age‐related changes in aortic 3D blood flow velocities and wall shear stress: Implications for the identification of altered hemodynamics in patients with aortic valve diseaseJournal of Magnetic Resonance Imaging, 2015
- Comparison of patient‐specific inlet boundary conditions in the numerical modelling of blood flow in abdominal aortic aneurysm diseaseInternational Journal for Numerical Methods in Biomedical Engineering, 2012
- Quantification of Hemodynamics in Abdominal Aortic Aneurysms During Rest and Exercise Using Magnetic Resonance Imaging and Computational Fluid DynamicsAnnals of Biomedical Engineering, 2010
- Effects of Exercise and Respiration on Hemodynamic Efficiency in CFD Simulations of the Total Cavopulmonary ConnectionAnnals of Biomedical Engineering, 2006
- Fluid wall shear stress measurements in a model of the human abdominal aorta: oscillatory behavior and relationship to atherosclerosisAtherosclerosis, 1994
- Coarctation and related aortic arch anomalies in hypoplastic left heart syndromeInternational Journal of Cardiology, 1985