ABAloma Blanch-Granada

Aloma Blanch-Granada

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Aloma Blanch-Granada has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Hemodynamic Characterization of Peripheral Arterio-Venous Malformations Using Rapid Contrast-Enhanced MR Imaging: An In Vitro and In Vivo Study

    by Camilla Giulia Calastra, Marika Bono, Aloma Blanch Granada, Aleksandra Tuleja, Sarah Maike Bernhard, Vanessa Diaz-Zuccarini, Stavroula Balabani, Dominik Obrist, Hendrik von Tengg-Kobligk, Bernd Jung

    Purpose: Peripheral arterio-venous malformations (pAVMs) are vascular defects often requiring extensive medical treatment. To improve disease management, hemodynamic markers based on 2D Digital Subtraction Angiography (DSA) data were previously defined to classify pAVMs. However, DSA offers only 2D information, involves ionizing radiation, and requires intra-arterial intervention. We hypothesized that pAVMs could be classified with the same approach with 3D dynamic contrast-enhanced MR-based data. To this end, the present work aims to develop a computational classification system for pAVMs using 3D dynamic contrast-enhanced MR-based data. Methods: A pAVM phantom was imaged using both DSA and MRI to validate the methodology, which was then applied to 10 MR-based in vivo datasets. A semi-automated vessel detection algorithm, based on the standard deviation of each voxel or pixel in time, was used. Classification was performed by identifying the time of arrival (CAToA) of contrast agent (CA) and the maximum time derivative of the CA transport in each pixel or voxel (CAsi). Results: Normalized CAToA and CAsi histograms showed no significant difference between in vitro DSA and MRI (respectively χ 2 = 0.20, p = 0.65 and χ 2 = 0.21, p = 0.65), validating the methodology to classify pAVMs. CAToA histograms for type II–IV AVMs derived from in vivo MR-based data aligned with DSA patterns and known hemodynamics. CAToA histograms of capillary–venulous AVMs were distinct, with non-zero values at later times than other AVM types, representing late venous drainage. Type IV AVMs histograms for CAsi were more right-skewed than those derived from types II and III pAVMs. Conclusions: MR image quality and temporal resolution are sufficient to allow a classification of pAVMs. This classification method has the potential to become a diagnostic tool for the surgical navigation of pAVMs for clinicians.


  • Hemodynamic Evaluation of Norwood Aortic Arch Geometry Compared to Native Arch Controls

    by Aloma Blanch-Granada, John F. LaDisa, Margaret M. Samyn, Joseph R. Cava, Stephanie S. Handler, Jennifer F Gerardin, Benjamin Goot, Mehdi Maadooliat, Viktor Hraška

    The Norwood procedure creates a reconstructed neo-aorta to provide unobstructed systemic cardiac output for hypoplastic left heart syndrome patients. We used patient-specific computational fluid dynamics (CFD) simulations incorporating physiologic boundary conditions to quantify hemodynamics for reconstructed aortic arch geometries versus native aortic arches from a control group of single ventricle patients. We hypothesized that reconstructed arches from Norwood patients (n = 5) would experience significant differences in time-averaged wall shear stress normalized to body surface area (TAWSSnBSA), oscillatory shear index (OSI), energy efficiency (Eeff), and energy loss (EL) versus controls (n = 3). CFD simulations were conducted using 3 T cardiac magnetic resonance imaging, blood flow, and pressure data. Simulations incorporated downstream vascular resistance and compliance to replicate patient physiology. TAWSSnBSA and OSI were quantified axially and circumferentially. Global differences in Eeff and EL were compared. Significance was assessed by Mann–Whitney U test. Norwood patients had higher TAWSSnBSA distal to the transverse arch at locations of residual narrowing presenting following coarctation correction, as well as higher OSI within ascending aorta and transverse arch regions (p < 0.05). EL correlated with patient features including cardiac output (r = 0.9) and BT-shunt resistance (r = –0.63) but did not correlate with arch measurements or morphology. These results indicate reconstructed arches from Norwood patients are exposed to altered wall shear stress and energy indices linked to cellular proliferation and inefficiency in prior studies. These results may help clinicians further understand what constitutes an optimally reconstructed arch after confirmation in larger studies.


  • Open Access

    Hemodynamic evaluation of Norwood arch geometry compared to native arch controls

    by Aloma Blanch-Granada, John F. LaDisa, Margaret M. Samyn, Joseph R. Cava, Stephanie S. Handler, Jennifer F Gerardin, Benjamin Goot, Mehdi Maadooliat, Viktor Hraška

    Background: The Norwood procedure creates a reconstructed neo-aorta to provide unobstructed systemic cardiac output (CO) for Hypoplastic Left Heart Syndrome (HLHS) patients. We used patient-specific computational fluid dynamics (CFD) simulations incorporating physiologic boundary conditions to quantify hemodynamics for reconstructed aortic arch geometries versus native aortic arches from a control group of single ventricle patients. We hypothesized that reconstructed arches from Norwood patients (n=5) would experience significant differences in time-averaged wall shear stress normalized to body surface area (TAWSSnBSA), oscillatory shear index (OSI), energy efficiency (Eeff), and energy loss (EL) versus controls (n=3). Methods: CFD simulations were conducted using 3T cardiac magnetic resonance imaging (CMR), blood flow and pressure data. Simulations incorporated downstream vascular resistance and compliance to replicate patient physiology. TAWSSnBSA and OSI were quantified longitudinally and circumferentially. Global differences in Eeff and EL were compared. Significance was assessed by Mann–Whitney U test. Results: Norwood patients had higher TAWSSnBSA distal to the transverse arch (TA) at locations of residual narrowing presenting following coarctation correction, as well as higher OSI within ascending aorta (AAo) and TA regions (p<0.05). EL correlated with patient features including cardiac output (r=0.9) and BT-shunt resistance (r=-0.63) but did not correlate with arch measurements or morphology. Conclusions: These results indicate reconstructed arches from Norwood patients are exposed to altered WSS and energy indices linked to cellular proliferation and inefficiency in prior studies. These results may help clinicians further understand what constitutes an optimally reconstructed arch after confirmation in larger studies.