Analysis of effective resistance and eddy-current losses in multiturn winding of high-frequency magnetic components
Authors:
- 19 February 2003
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 39 (1) , 539-548
Abstract
This paper develops a numerical model for calculation of eddy-current losses in a multiturn winding of a high-frequency transformer. The model assumes periodic arrangement of conductors, and uses the repeat elementary cell concept. The paper proposes analytical expressions and graphic dependences to determine effective frequency-dependent resistance of the winding. It computes the leakage field in the transformer window, taking into consideration the effective magnetic permeability of the multiturn winding as a heterogeneous medium. Finally, it analyzes the values of the resistance at various frequencies for two types of winding (solid conductor winding and Litz wire winding) by numerical and experimental methods.Keywords
This publication has 7 references indexed in Scilit:
- A full procedure to model high frequency transformer windings2002
- Accurate analytical model of winding losses in round Litz wire windingsIEEE Transactions on Magnetics, 2001
- Loss comparison in the design of high frequency inductors and transformersIEEE Transactions on Magnetics, 1999
- Obtaining a frequency-dependent and distributed-effects model of magnetic components from actual measurementsIEEE Transactions on Magnetics, 1999
- Homogenization technique for Maxwell equations in periodic structuresIEEE Transactions on Magnetics, 1997
- A novel approach for minimizing high-frequency transformer copper lossesIEEE Transactions on Power Electronics, 1988
- Effects of eddy currents in transformer windingsProceedings of the Institution of Electrical Engineers, 1966