Risk factors for periprosthetic femoral fracture risk around a cemented polished taper-slip stem using an osteoporotic composite bone model
- 18 January 2024
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 238 (3) , 324-331
Abstract
This biomechanical study aimed to determine if variations in stem material, stem geometry, stem offset and cement viscosity affect mechanical resistance to postoperative periprosthetic fracture (PFF) after hip arthroplasty with a commonly used cemented polished taper-slip (PTS) stem (CPT, Zimmer Biomet) in a novel osteoporotic composite femoral bone model. Thirty-six osteoporotic composite femoral models were tested using a standardised in-vitro loading technique to simulate a typical PFF. Outcome measures were torque to failure (N), fracture energy (N/m2) and rotation to failure (°). Comparisons were made by stem material (cobalt chrome vs stainless steel), stem geometry (CPT stem vs Exeter stem), stem offset (standard offset vs extra extended offset) and cement viscosity (high viscosity vs low viscosity). Statistical comparisons were carried out with significance set at p < 0.05. All tested samples produced clinically representative fracture patterns with varying degrees of bone and cement comminution. There was no statistically significant difference in torque to failure, fracture energy or rotation to failure between any of the compared variables (all p > 0.05). This is the first biomechanical study on mechanical resistance to PFF using osteoporotic composite bone models. For the CPT stem, it confirms that stem material, stem offset, stem geometry and cement viscosity do not affect mechanical resistance to PFF in an osteoporotic bone model.Keywords
Funding Information
- Zimmer Biomet
This publication has 27 references indexed in Scilit:
- Validation of primary metal-on-metal hip arthroplasties on the National Joint Registry for England, Wales and Northern Ireland using data from the London Implant Retrieval CentreThe Bone & Joint Journal, 2015
- High risk of early periprosthetic fractures after primary hip arthroplasty in elderly patients using a cemented, tapered, polished stemActa Orthopaedica, 2014
- Periprosthetic Femoral Fracture within Two Years After Total Hip ReplacementJournal of Bone and Joint Surgery, 2014
- The Unified Classification System (UCS): improving our understanding of periprosthetic fracturesThe Bone & Joint Journal, 2014
- Periprosthetic Fracture Torque for Short Versus Standard Cemented Hip Stems: An Experimental In Vitro StudyThe Journal of Arthroplasty, 2014
- Cemented, cementless, and hybrid prostheses for total hip replacement: cost effectiveness analysisBMJ, 2013
- The importance of adequate stem anteversion for rotational stability in cemented total hip replacementThe Bone & Joint Journal, 2013
- A Review of Periprosthetic Femoral Fractures Associated With Total Hip ArthroplastyGeriatric Orthopaedic Surgery & Rehabilitation, 2012
- Risk factors for Periprosthetic Fractures of the Hip: A Survivorship AnalysisClinical Orthopaedics and Related Research, 2008
- The operation of the century: total hip replacementThe Lancet, 2007