Sameer Jain
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sameer Jain has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Robert Michael West
Leeds Institute of Health Sciences, University of Leeds, Leeds, UK
4 shared publications - Hemant Pandit
Leeds Institute of Rheumatic and Musculoskeletal Medicine, School of Medicine, University of Leeds, Leeds LS9 7TF, UK
3 shared publications - Chloe E. H. Scott
Edinburgh Orthopaedics, Royal Infirmary of Edinburgh, Edinburgh, UK
2 shared publications - Deepak Menon
Trauma and Orthopaedics, Leeds Teaching Hospitals NHS Trust, Leeds, UK
2 shared publications Hemant Pandit
Chapel Allerton Hospital, Leeds Teaching Hospitals NHS Trust, Leeds, UK
2 shared publications- Jonathan Nicholas Lamb
Affiliations Centre for Hip Surgery, Wrightington Hospital, Wigan, United Kingdom, Musculoskeletal Research Unit, Translational Health Sciences, Bristol Medical School, Southmead Hospital, Bristol, United Kingdom
2 shared publications
Latest Publications
- 18 January 2024
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 238 (3) , 324-331
Risk factors for periprosthetic femoral fracture risk around a cemented polished taper-slip stem using an osteoporotic composite bone model
This biomechanical study aimed to determine if variations in stem material, stem geometry, stem offset and cement viscosity affect mechanical resistance to postoperative periprosthetic fracture (PFF) after hip arthroplasty with a commonly used cemented polished taper-slip (PTS) stem (CPT, Zimmer Biomet) in a novel osteoporotic composite femoral bone model. Thirty-six osteoporotic composite femoral models were tested using a standardised in-vitro loading technique to simulate a typical PFF. Outcome measures were torque to failure (N), fracture energy (N/m2) and rotation to failure (°). Comparisons were made by stem material (cobalt chrome vs stainless steel), stem geometry (CPT stem vs Exeter stem), stem offset (standard offset vs extra extended offset) and cement viscosity (high viscosity vs low viscosity). Statistical comparisons were carried out with significance set at p < 0.05. All tested samples produced clinically representative fracture patterns with varying degrees of bone and cement comminution. There was no statistically significant difference in torque to failure, fracture energy or rotation to failure between any of the compared variables (all p > 0.05). This is the first biomechanical study on mechanical resistance to PFF using osteoporotic composite bone models. For the CPT stem, it confirms that stem material, stem offset, stem geometry and cement viscosity do not affect mechanical resistance to PFF in an osteoporotic bone model.
- 18 January 2024
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 238 (3) , 324-331
Risk factors for periprosthetic femoral fracture risk around a cemented polished taper-slip stem using an osteoporotic composite bone model
This biomechanical study aimed to determine if variations in stem material, stem geometry, stem offset and cement viscosity affect mechanical resistance to postoperative periprosthetic fracture (PFF) after hip arthroplasty with a commonly used cemented polished taper-slip (PTS) stem (CPT, Zimmer Biomet) in a novel osteoporotic composite femoral bone model. Thirty-six osteoporotic composite femoral models were tested using a standardised in-vitro loading technique to simulate a typical PFF. Outcome measures were torque to failure (N), fracture energy (N/m2) and rotation to failure (°). Comparisons were made by stem material (cobalt chrome vs stainless steel), stem geometry (CPT stem vs Exeter stem), stem offset (standard offset vs extra extended offset) and cement viscosity (high viscosity vs low viscosity). Statistical comparisons were carried out with significance set at p < 0.05. All tested samples produced clinically representative fracture patterns with varying degrees of bone and cement comminution. There was no statistically significant difference in torque to failure, fracture energy or rotation to failure between any of the compared variables (all p > 0.05). This is the first biomechanical study on mechanical resistance to PFF using osteoporotic composite bone models. For the CPT stem, it confirms that stem material, stem offset, stem geometry and cement viscosity do not affect mechanical resistance to PFF in an osteoporotic bone model.
- 1 January 2024
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 106-B (1) , 11-15
Cemented femoral stem design and postoperative periprosthetic fracture risk following total hip arthroplasty
Polished taper-slip (PTS) cemented stems have an excellent clinical track record and are the most common stem type used in primary total hip arthroplasty (THA) in the UK. Due to low rates of aseptic loosening, they have largely replaced more traditional composite beam (CB) cemented stems. However, there is now emerging evidence from multiple joint registries that PTS stems are associated with higher rates of postoperative periprosthetic femoral fracture (PFF) compared to their CB stem counterparts. The risk of both intraoperative and postoperative PFF remains greater with uncemented stems compared to either of these cemented stem subtypes. PFF continues to be a devastating complication following primary THA and is associated with high complication and mortality rates. Recent efforts have focused on identifying implant-related risk factors for PFF in order to guide preventative strategies, and therefore the purpose of this article is to present the current evidence on the effect of cemented femoral stem design on the risk of PFF.Cite this article: Bone Joint J 2024;106-B(1):11–15.
- 1 January 2024
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 106-B (1) , 11-15
Cemented femoral stem design and postoperative periprosthetic fracture risk following total hip arthroplasty
Polished taper-slip (PTS) cemented stems have an excellent clinical track record and are the most common stem type used in primary total hip arthroplasty (THA) in the UK. Due to low rates of aseptic loosening, they have largely replaced more traditional composite beam (CB) cemented stems. However, there is now emerging evidence from multiple joint registries that PTS stems are associated with higher rates of postoperative periprosthetic femoral fracture (PFF) compared to their CB stem counterparts. The risk of both intraoperative and postoperative PFF remains greater with uncemented stems compared to either of these cemented stem subtypes. PFF continues to be a devastating complication following primary THA and is associated with high complication and mortality rates. Recent efforts have focused on identifying implant-related risk factors for PFF in order to guide preventative strategies, and therefore the purpose of this article is to present the current evidence on the effect of cemented femoral stem design on the risk of PFF.Cite this article: Bone Joint J 2024;106-B(1):11–15.
- 1 May 2023
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 105-B (5) , 481-486
Which Unified Classification System type B periprosthetic fractures around cemented polished tapered stems should not be fixed?
The Unified Classification System (UCS), or Vancouver system, is a validated and widely used classification system to guide the management of periprosthetic femoral fractures. It suggests that well-fixed stems (type B1) can be treated with fixation but that loose stems (types B2 and B3) should be revised. Determining whether a stem is loose can be difficult and some authors have questioned how to apply this classification system to polished taper slip stems which are, by definition, loose within their cement mantle. Recent evidence has challenged the common perception that revision surgery is preferable to fixation surgery for UCS-B periprosthetic fractures around cemented polished taper slip stems. Indications for fixation include an anatomically reducible fracture and cement mantle, a well-fixed femoral bone-cement interface, and a well-functioning acetabular component. However, not all type B fractures can or should be managed with fixation due to the risk of early failure. This annotation details specific fracture patterns that should not be managed with fixation alone.Cite this article: Bone Joint J 2023;105-B(5):481–486.
- 1 May 2023
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 105-B (5) , 481-486
Which Unified Classification System type B periprosthetic fractures around cemented polished tapered stems should not be fixed?
The Unified Classification System (UCS), or Vancouver system, is a validated and widely used classification system to guide the management of periprosthetic femoral fractures. It suggests that well-fixed stems (type B1) can be treated with fixation but that loose stems (types B2 and B3) should be revised. Determining whether a stem is loose can be difficult and some authors have questioned how to apply this classification system to polished taper slip stems which are, by definition, loose within their cement mantle. Recent evidence has challenged the common perception that revision surgery is preferable to fixation surgery for UCS-B periprosthetic fractures around cemented polished taper slip stems. Indications for fixation include an anatomically reducible fracture and cement mantle, a well-fixed femoral bone-cement interface, and a well-functioning acetabular component. However, not all type B fractures can or should be managed with fixation due to the risk of early failure. This annotation details specific fracture patterns that should not be managed with fixation alone.Cite this article: Bone Joint J 2023;105-B(5):481–486.
- 1 February 2023
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 105-B (2) , 124-134
A multicentre comparative analysis of fixation versus revision surgery for periprosthetic femoral fractures following total hip arthroplasty with a cemented polished taper-slip femoral component
Aims: The aim of this study was to compare open reduction and internal fixation (ORIF) with revision surgery for the surgical management of Unified Classification System (UCS) type B periprosthetic femoral fractures around cemented polished taper-slip femoral components following primary total hip arthroplasty (THA). Methods: Data were collected for patients admitted to five UK centres. The primary outcome measure was the two-year reoperation rate. Secondary outcomes were time to surgery, transfusion requirements, critical care requirements, length of stay, two-year local complication rates, six-month systemic complication rates, and mortality rates. Comparisons were made by the form of treatment (ORIF vs revision) and UCS type (B1 vs B2/B3). Kaplan-Meier survival analysis was performed with two-year reoperation for any reason as the endpoint. Results: A total of 317 periprosthetic fractures (in 317 patients) with a median follow-up of 3.6 years (interquartile range (IQR) 2.0 to 5.4) were included. The fractures were type B1 in 133 (42.0%), B2 in 170 (53.6%), and B3 in 14 patients (4.4%). ORIF was performed in 167 (52.7%) and revision in 150 patients (47.3%). The two-year reoperation rate (15.3% vs 7.2%; p = 0.021), time to surgery (4.0 days (IQR 2.0 to 7.0) vs 2.0 days (IQR 1.0 to 4.0); p < 0.001), transfusion requirements (55 patients (36.7%) vs 42 patients (25.1%); p = 0.026), critical care requirements (36 patients (24.0%) vs seven patients (4.2%); p < 0.001) and two-year local complication rates (26.7% vs 9.0%; p < 0.001) were significantly higher in the revision group. The two-year rate of survival was significantly higher for ORIF (91.9% (standard error (SE) 0.023%) vs 83.9% (SE 0.031%); p = 0.032) compared with revision. For B1 fractures, the two-year reoperation rate was significantly higher for revision compared with ORIF (29.4% vs 6.0%; p = 0.002) but this was similar for B2 and B3 fractures (9.8% vs 13.5%; p = 0.341). The most common indication for reoperation after revision was dislocation (12 patients; 8.0%). Conclusion: Revision surgery has higher reoperation rates, longer surgical waiting times, higher transfusion requirements, and higher critical care requirements than ORIF in the management of periprosthetic fractures around polished taper-slip femoral components after THA. ORIF is a safe option providing anatomical reconstruction is achievable. Cite this article: Bone Joint J 2023;105-B(2):124–134.
- 1 February 2023
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 105-B (2) , 124-134
A multicentre comparative analysis of fixation versus revision surgery for periprosthetic femoral fractures following total hip arthroplasty with a cemented polished taper-slip femoral component
Aims: The aim of this study was to compare open reduction and internal fixation (ORIF) with revision surgery for the surgical management of Unified Classification System (UCS) type B periprosthetic femoral fractures around cemented polished taper-slip femoral components following primary total hip arthroplasty (THA). Methods: Data were collected for patients admitted to five UK centres. The primary outcome measure was the two-year reoperation rate. Secondary outcomes were time to surgery, transfusion requirements, critical care requirements, length of stay, two-year local complication rates, six-month systemic complication rates, and mortality rates. Comparisons were made by the form of treatment (ORIF vs revision) and UCS type (B1 vs B2/B3). Kaplan-Meier survival analysis was performed with two-year reoperation for any reason as the endpoint. Results: A total of 317 periprosthetic fractures (in 317 patients) with a median follow-up of 3.6 years (interquartile range (IQR) 2.0 to 5.4) were included. The fractures were type B1 in 133 (42.0%), B2 in 170 (53.6%), and B3 in 14 patients (4.4%). ORIF was performed in 167 (52.7%) and revision in 150 patients (47.3%). The two-year reoperation rate (15.3% vs 7.2%; p = 0.021), time to surgery (4.0 days (IQR 2.0 to 7.0) vs 2.0 days (IQR 1.0 to 4.0); p < 0.001), transfusion requirements (55 patients (36.7%) vs 42 patients (25.1%); p = 0.026), critical care requirements (36 patients (24.0%) vs seven patients (4.2%); p < 0.001) and two-year local complication rates (26.7% vs 9.0%; p < 0.001) were significantly higher in the revision group. The two-year rate of survival was significantly higher for ORIF (91.9% (standard error (SE) 0.023%) vs 83.9% (SE 0.031%); p = 0.032) compared with revision. For B1 fractures, the two-year reoperation rate was significantly higher for revision compared with ORIF (29.4% vs 6.0%; p = 0.002) but this was similar for B2 and B3 fractures (9.8% vs 13.5%; p = 0.341). The most common indication for reoperation after revision was dislocation (12 patients; 8.0%). Conclusion: Revision surgery has higher reoperation rates, longer surgical waiting times, higher transfusion requirements, and higher critical care requirements than ORIF in the management of periprosthetic fractures around polished taper-slip femoral components after THA. ORIF is a safe option providing anatomical reconstruction is achievable. Cite this article: Bone Joint J 2023;105-B(2):124–134.
- Open Access
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
A Cost Analysis of Treating Postoperative Periprosthetic Femoral Fractures Following Hip Replacement Surgery in a UK Tertiary Referral Centre
AimThis study: aims to evaluate costs associated with periprosthetic femoral fracture (PFF) treatment at a UK tertiary referral centre. Methods: This study included 128 consecutive PFFs admitted from 02/04/2014-19/05/2020. Financial data were provided by Patient Level Information and Costing Systems. Primary outcomes were median cost and margin. Secondary outcomes were length of stay, blood transfusion, critical care, 30-day readmission, 2-year local complication, 2-year systemic complication, 2-year reoperation and 30-day mortality rates. Statistical comparisons were made between treatment type. Statistical significance was set at p<0.05. Results: Across the cohort, median cost was £15,644.00 (IQR £11,031.00-£22,255.00) and median loss was £3757.50 (£599.20-£8296.20). The highest costs were ward stay (£3994.00, IQR £1,765.00-£7,013.00), theatre utilisation (£2962.00, IQR £0.00-£4,286.00) and overheads (£1705.10, IQR £896.70-£2432.20). Cost (£17,455.00 [IQR, £13,194.00-£23,308.00] versus £7697.00 [IQR £3871.00-£10,847.00], p0.05). Conclusion: PFF treatment costs are high with inadequate reimbursement from NHS tariff. Work is needed to address this disparity and reduce hospital costs. Cost should not be used to decide between ORIF and revision surgery
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Cost Analysis of Treating Postoperative Periprosthetic Femoral Fractures Following Hip Replacement Surgery in a UK Tertiary Referral Centre
AimThis study: aims to evaluate costs associated with periprosthetic femoral fracture (PFF) treatment at a UK tertiary referral centre. Methods: This study included 128 consecutive PFFs admitted from 02/04/2014-19/05/2020. Financial data were provided by Patient Level Information and Costing Systems. Primary outcomes were median cost and margin. Secondary outcomes were length of stay, blood transfusion, critical care, 30-day readmission, 2-year local complication, 2-year systemic complication, 2-year reoperation and 30-day mortality rates. Statistical comparisons were made between treatment type. Statistical significance was set at p<0.05. Results: Across the cohort, median cost was £15,644.00 (IQR £11,031.00-£22,255.00) and median loss was £3757.50 (£599.20-£8296.20). The highest costs were ward stay (£3994.00, IQR £1,765.00-£7,013.00), theatre utilisation (£2962.00, IQR £0.00-£4,286.00) and overheads (£1705.10, IQR £896.70-£2432.20). Cost (£17,455.00 [IQR, £13,194.00-£23,308.00] versus £7697.00 [IQR £3871.00-£10,847.00], p0.05). Conclusion: PFF treatment costs are high with inadequate reimbursement from NHS tariff. Work is needed to address this disparity and reduce hospital costs. Cost should not be used to decide between ORIF and revision surgery
- 25 June 2020
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 102 (18) , 1600-1608
Risk Factors for Revision of Polished Taper-Slip Cemented Stems for Periprosthetic Femoral Fracture After Primary Total Hip Replacement
Background: Total hip replacement (THR) with a cemented polished taper-slip (PTS) femoral stem has excellent long-term results but is associated with a higher postoperative periprosthetic femoral fracture (PFF) risk compared with composite beam stems. This study aimed to identify risk factors associated with PFF revision following THR with PTS stems. Methods: In a retrospective cohort study, 299,019 primary THRs using PTS stems from the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man (NJR) were included, with a median follow-up of 5.2 years (interquartile range [IQR], 3.1 to 8.2 years). The adjusted hazard ratio (HR) of PFF revision was estimated for each variable using multivariable Cox survival regression analysis. Results: Of 299,019 THR cases, 1,055 underwent revision for PFF at a median time of 3.1 years (IQR, 1.0 to 6.1 years). The mean age (and standard deviation) was 72 ± 9.7 years, 64.3% (192,365 patients) were female, and 82.6% (247,126 patients) had an American Society of Anesthesiologists (ASA) class of 1 or 2. Variables associated with increased PFF were increasing age (HR, 1.02 per year), intraoperative fracture (HR, 2.57 [95% confidence interval (CI), 1.42 to 4.66]), ovaloid (HR, 1.96 [95% CI, 1.22 to 3.16]) and round cross-sectional shapes (HR, 9.58 [95% CI, 2.29 to 40.12]), increasing stem offset (HR, 1.07 per millimeter), increasing head size (HR, 1.04 per millimeter), THR performed from 2012 to 2016 (HR, 1.45 [95% CI, 1.18 to 1.78]), cobalt-chromium stem material (HR, 6.7 [95% CI, 3.0 to 15.4]), and cobalt-chromium stems with low-viscosity cement (HR, 22.88 [95% CI, 9.90 to 52.85]). Variables associated with a decreased risk of PFF revision were female sex (HR, 0.52 [95% CI, 0.45 to 0.59]), increasing stem length (HR, 0.97 per millimeter), and a ceramic-on-polyethylene bearing (HR, 0.55 [95% CI, 0.36 to 0.85]). Conclusions: Increased risk of PFF revision was associated with PTS stems that are short, have high offset, are used with large femoral heads, are made of cobalt-chromium, or have ovaloid or round cross-sectional shapes. Large increases in PFF risk were associated with cobalt-chromium stems used with low-viscosity cement. Further study is required to confirm causation. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 25 June 2020
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 102 (18) , 1600-1608
Risk Factors for Revision of Polished Taper-Slip Cemented Stems for Periprosthetic Femoral Fracture After Primary Total Hip Replacement
Background: Total hip replacement (THR) with a cemented polished taper-slip (PTS) femoral stem has excellent long-term results but is associated with a higher postoperative periprosthetic femoral fracture (PFF) risk compared with composite beam stems. This study aimed to identify risk factors associated with PFF revision following THR with PTS stems. Methods: In a retrospective cohort study, 299,019 primary THRs using PTS stems from the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man (NJR) were included, with a median follow-up of 5.2 years (interquartile range [IQR], 3.1 to 8.2 years). The adjusted hazard ratio (HR) of PFF revision was estimated for each variable using multivariable Cox survival regression analysis. Results: Of 299,019 THR cases, 1,055 underwent revision for PFF at a median time of 3.1 years (IQR, 1.0 to 6.1 years). The mean age (and standard deviation) was 72 ± 9.7 years, 64.3% (192,365 patients) were female, and 82.6% (247,126 patients) had an American Society of Anesthesiologists (ASA) class of 1 or 2. Variables associated with increased PFF were increasing age (HR, 1.02 per year), intraoperative fracture (HR, 2.57 [95% confidence interval (CI), 1.42 to 4.66]), ovaloid (HR, 1.96 [95% CI, 1.22 to 3.16]) and round cross-sectional shapes (HR, 9.58 [95% CI, 2.29 to 40.12]), increasing stem offset (HR, 1.07 per millimeter), increasing head size (HR, 1.04 per millimeter), THR performed from 2012 to 2016 (HR, 1.45 [95% CI, 1.18 to 1.78]), cobalt-chromium stem material (HR, 6.7 [95% CI, 3.0 to 15.4]), and cobalt-chromium stems with low-viscosity cement (HR, 22.88 [95% CI, 9.90 to 52.85]). Variables associated with a decreased risk of PFF revision were female sex (HR, 0.52 [95% CI, 0.45 to 0.59]), increasing stem length (HR, 0.97 per millimeter), and a ceramic-on-polyethylene bearing (HR, 0.55 [95% CI, 0.36 to 0.85]). Conclusions: Increased risk of PFF revision was associated with PTS stems that are short, have high offset, are used with large femoral heads, are made of cobalt-chromium, or have ovaloid or round cross-sectional shapes. Large increases in PFF risk were associated with cobalt-chromium stems used with low-viscosity cement. Further study is required to confirm causation. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 1 February 2019
- Published by SAGE Publications in Surgical Infections
- Vol. 20 (2) , 151-158
Laminar Air Flow Handling Systems in the Operating Room
Background: Surgical site infection is associated with a substantial healthcare burden and remains one of the most challenging complications to treat. Airborne particles carrying contaminating micro-organisms are responsible for the majority of these infections. Methods: Various operating theater ventilatory systems have been developed to prevent direct airborne bacterial inoculation of the surgical wound. Laminar air flow uses positive pressure air currents through filtration units to direct air streams away from the operative field in order to create an ultraclean zone around the operative site. Discussion: Early studies reported lower infection rates with laminar air flow and therefore it became the accepted standard for implant-related surgery. However, more recent evidence has questioned its clinical importance. The purpose of this article is to review contemporary laminar air flow handling systems and the current evidence behind their use.
- 1 February 2019
- Published by SAGE Publications in Surgical Infections
- Vol. 20 (2) , 151-158
Laminar Air Flow Handling Systems in the Operating Room
Background: Surgical site infection is associated with a substantial healthcare burden and remains one of the most challenging complications to treat. Airborne particles carrying contaminating micro-organisms are responsible for the majority of these infections. Methods: Various operating theater ventilatory systems have been developed to prevent direct airborne bacterial inoculation of the surgical wound. Laminar air flow uses positive pressure air currents through filtration units to direct air streams away from the operative field in order to create an ultraclean zone around the operative site. Discussion: Early studies reported lower infection rates with laminar air flow and therefore it became the accepted standard for implant-related surgery. However, more recent evidence has questioned its clinical importance. The purpose of this article is to review contemporary laminar air flow handling systems and the current evidence behind their use.
- 1 August 2018
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 100B (8) , 1010-1017
Reverse hybrid total hip arthroplasty A SURVIVAL ANALYSIS OF 1082 CONSECUTIVE CASES WITH MINIMUM FIVE-YEAR FOLLOW-UP
Aims This study aimed to evaluate implant survival of reverse hybrid total hip arthroplasty (THA) at medium-term follow-up. Patients and Methods A consecutive series of 1082 THAs in 982 patients with mean follow-up of 7.9 years (5 to 11.3) is presented. Mean age was 69.2 years (21 to 94). Of these, 194 (17.9%) were in patients under 60 years, 663 (61.3%) in female patients and 348 (32.2%) performed by a trainee. Head size was 28 mm in 953 hips (88.1%) or 32 mm in 129 hips (11.9%). Survival analysis was performed and subgroups compared using log rank tests. Results Ten-year survival (122 hips at risk) was 97.2% (95% confidence interval (CI) 95.77 to 98.11) for all-cause revision. There was no difference in survival by age (p = 0.50), gender (p = 0.78), head size (p = 0.63) or surgeon grade (p = 0.36). No acetabular components underwent revision for aseptic loosening in the entire series. Four (0.4%) aseptic stem failures occurred early at a mean of 2.5 years (0.6 to 4.8) and were associated with age under 60 years (p = 0.015). There was no difference in survival by gender (p = 0.12), head size (p = 0.43) or surgeon grade (p = 0.77) for stem revision. Conclusion This is the largest reported study into reverse hybrid THA and it confirms successful outcomes, irrespective of age, gender, head size and surgeon grade.
- 1 August 2018
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 100B (8) , 1010-1017
Reverse hybrid total hip arthroplasty A SURVIVAL ANALYSIS OF 1082 CONSECUTIVE CASES WITH MINIMUM FIVE-YEAR FOLLOW-UP
Aims This study aimed to evaluate implant survival of reverse hybrid total hip arthroplasty (THA) at medium-term follow-up. Patients and Methods A consecutive series of 1082 THAs in 982 patients with mean follow-up of 7.9 years (5 to 11.3) is presented. Mean age was 69.2 years (21 to 94). Of these, 194 (17.9%) were in patients under 60 years, 663 (61.3%) in female patients and 348 (32.2%) performed by a trainee. Head size was 28 mm in 953 hips (88.1%) or 32 mm in 129 hips (11.9%). Survival analysis was performed and subgroups compared using log rank tests. Results Ten-year survival (122 hips at risk) was 97.2% (95% confidence interval (CI) 95.77 to 98.11) for all-cause revision. There was no difference in survival by age (p = 0.50), gender (p = 0.78), head size (p = 0.63) or surgeon grade (p = 0.36). No acetabular components underwent revision for aseptic loosening in the entire series. Four (0.4%) aseptic stem failures occurred early at a mean of 2.5 years (0.6 to 4.8) and were associated with age under 60 years (p = 0.015). There was no difference in survival by gender (p = 0.12), head size (p = 0.43) or surgeon grade (p = 0.77) for stem revision. Conclusion This is the largest reported study into reverse hybrid THA and it confirms successful outcomes, irrespective of age, gender, head size and surgeon grade.