Modelling the electrical resistivity of concrete with varied water and chloride contents
- 1 June 2020
- journal article
- research article
- Published by Emerald Publishing in Magazine of Concrete Research
- Vol. 72 (11) , 552-563
Abstract
The electrical resistivity of concrete is an important property in the assessment of reinforcement corrosion in concrete and an essential parameter in the design and operation of cathodic protection for reinforced-concrete (RC) structures. Water and chloride contents in concrete are highly variable in RC structures in real-world hostile environments, meaning that characterisation of their coupled effects on concrete electrical resistivity is important. The currently available models are investigated in this paper. As all the current models are purely empirical, an improvement with a semi-empirical model is proposed. The improvement highlights the intrinsic linkage between concrete electrical resistivity and water content and the pore size distribution of concrete. The proposed model was tested using two sets of experimental data and was also compared with other two empirical models.Keywords
This publication has 20 references indexed in Scilit:
- Electrical resistivity measurement of unsaturated concrete samplesMagazine of Concrete Research, 2014
- The selection and use of cathodic protection systems for the repair of reinforced concrete structuresConstruction and Building Materials, 2013
- A physico-chemical model for the water vapour sorption isotherm of hardened cementitious materialsConstruction and Building Materials, 2012
- Prediction model for the time-varying corrosion rate of rebar based on micro-environment in concreteConstruction and Building Materials, 2012
- Modeling cathodic prevention for unconventional concrete in salt‐laden environmentAnti-Corrosion Methods and Materials, 2012
- PHASE DETERMINISTIC MODELING OF WATER-VAPOR RETENTION IN POROUS MEDIA AND ITS POTENTIAL IN UNSATURATED FLOW APPLICATIONJournal of Porous Media, 2010
- Influence of temperature and humidity on Portland cement mortar resistivity monitored with inner sensorsMaterials and Corrosion, 2009
- Effect of moisture, chloride and sulphate contamination on the electrical resistivity of Portland cement concreteConstruction and Building Materials, 1996
- Influence of the degree of pore saturation on the resistivity of concrete and the corrosion rate of steel reinforcementCement and Concrete Research, 1993
- The conduction of electricity through concreteMagazine of Concrete Research, 1981