Five-Year Efficacy and Safety of TiNO-Coated Stents Versus Drug-Eluting Stents in Acute Coronary Syndrome: A Meta-Analysis
Open Access
- 6 November 2023
- journal article
- review article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (21) , 6952
Abstract
(1) Background: Percutaneous coronary interventions (PCI) in patients with acute coronary syndrome (ACS) are performed with titanium-nitride-oxide-coated stents (TiNOSs) or drug-eluting stents (DESs). The initial completion of this prospective systematic literature review (SLR) of prospective randomized controlled trials (RCTs) showed that TiNOSs are non-inferior to DESs in major adverse cardiac event (MACE) rates and present a lower risk of recurrent myocardial infarction (MI) at 1-year follow-up. This iteration of the SLR protocol performs the critical assessment of 5-year follow-up outcomes with clinical validity and generalizability assessments. (2) Methods: The previously described SLR and meta-analysis protocol, per PRISMA, Cochrane methods, and GRADE, was applied to 5-year follow-up outcomes. (3) Results: Three RCTs were eligible, comprising 1620 patients with TiNOS vs. 1123 with DES. The pooled risk ratios (RRs) and 95% confidence intervals were MACE 0.82 [0.68, 0.99], MI 0.58 [0.44, 0.78], cardiac death (CD) 0.46 [0.28, 0.76], ischemia-driven target lesion revascularization (TLR) 1.03 [0.79, 1.33], probable or definite stent thrombosis (ST) 0.32 [0.21, 0.59], and all-cause mortality (TD) 0.84 [0.63, 1.12]. The evidence certainty was high in MACE, CD, MI, and ST, and moderate in TLR and TD. (4) Conclusions: TiNOSs in ACS at 5-year follow-up appear safer than DESs and equally efficacious. The pooled RRs stratified by clinical presentation and stent type will be required to test this meta-analysis’s clinical validity and generalize its results to patient populations with varying proportions of clinical presentations and DES options.Keywords
All Related Versions
This publication has 82 references indexed in Scilit:
- A prospective randomised comparison of titanium-nitride-oxide-coated bioactive stents with everolimus-eluting stents in acute coronary syndrome: the BASE-ACS trialEuroIntervention, 2012
- GRADE guidelines 6. Rating the quality of evidence—imprecisionJournal of Clinical Epidemiology, 2011
- Comparison of Titanium-Nitride-Oxide–Coated Stents With Zotarolimus-Eluting Stents for Coronary RevascularizationJACC: Cardiovascular Interventions, 2011
- Four-Year Follow-Up of TYPHOON (Trial to Assess the Use of the CYPHer Sirolimus-Eluting Coronary Stent in Acute Myocardial Infarction Treated With BallOON Angioplasty)JACC: Cardiovascular Interventions, 2011
- Recent Trends in the Incidence, Treatment, and Outcomes of Patients with STEMI and NSTEMIThe American Journal of Medicine, 2011
- Role of the Paclitaxel-Eluting Stent and Tirofiban in Patients With ST-Elevation Myocardial Infarction Undergoing Postfibrinolysis AngioplastyCirculation: Cardiovascular Interventions, 2010
- The PASEO (PaclitAxel or Sirolimus-Eluting Stent Versus Bare Metal Stent in Primary Angioplasty) Randomized TrialJACC: Cardiovascular Interventions, 2009
- GRADE: an emerging consensus on rating quality of evidence and strength of recommendationsBMJ, 2008
- Sirolimus-eluting stents compared with standard stents in the treatment of patients with primary angioplastyAmerican Heart Journal, 2007
- A modified test for small‐study effects in meta‐analyses of controlled trials with binary endpointsStatistics in Medicine, 2005