Comparison of 31P saturation and inversion magnetization transfer in human liver and skeletal muscle using a clinical MR system and surface coils
- 7 December 2014
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 28 (2) , 188-199
Abstract
31P MRS magnetization transfer (31P‐MT) experiments allow the estimation of exchange rates of biochemical reactions, such as the creatine kinase equilibrium and adenosine triphosphate (ATP) synthesis. Although various 31P‐MT methods have been successfully used on isolated organs or animals, their application on humans in clinical scanners poses specific challenges. This study compared two major 31P‐MT methods on a clinical MR system using heteronuclear surface coils. Although saturation transfer (ST) is the most commonly used 31P‐MT method, sequences such as inversion transfer (IT) with short pulses might be better suited for the specific hardware and software limitations of a clinical scanner. In addition, small NMR‐undetectable metabolite pools can transfer MT to NMR‐visible pools during long saturation pulses, which is prevented with short pulses. 31P‐MT sequences were adapted for limited pulse length, for heteronuclear transmit–receive surface coils with inhomogeneous B1, for the need for volume selection and for the inherently low signal‐to‐noise ratio (SNR) on a clinical 3‐T MR system. The ST and IT sequences were applied to skeletal muscle and liver in 10 healthy volunteers. Monte‐Carlo simulations were used to evaluate the behavior of the IT measurements with increasing imperfections. In skeletal muscle of the thigh, ATP synthesis resulted in forward reaction constants (k) of 0.074 ±0.022 s–1 (ST) and 0.137 ±0.042 s–1 (IT), whereas the creatine kinase reaction yielded 0.459 ±0.089 s–1 (IT). In the liver, ATP synthesis resulted in k = 0.267 ±0.106 s–1 (ST), whereas the IT experiment yielded no consistent results. ST results were close to literature values; however, the IT results were either much larger than the corresponding ST values and/or were widely scattered. To summarize, ST and IT experiments can both be implemented on a clinical body scanner with heteronuclear transmit–receive surface coils; however, ST results are much more robust against experimental imperfections than the current implementation of IT. Copyright © 2014 John Wiley & Sons, Ltd.Keywords
Funding Information
- Swiss National Science Foundation (#31003A-132935, #310030-149779)
This publication has 38 references indexed in Scilit:
- Quantitative imaging of energy expenditure in human brainNeuroImage, 2012
- Standard magnetic resonance-based measurements of the Pi→ATP rate do not index the rate of oxidative phosphorylation in cardiac and skeletal musclesAmerican Journal of Physiology-Cell Physiology, 2011
- Liver ATP Synthesis Is Lower and Relates to Insulin Sensitivity in Patients With Type 2 DiabetesDiabetes Care, 2011
- Triple repetition time saturation transfer (TRiST) 31P spectroscopy for measuring human creatine kinase reaction kineticsMagnetic Resonance in Medicine, 2010
- Quantitative ATP synthesis in human liver measured by localized 31P spectroscopy using the magnetization transfer experimentNMR in Biomedicine, 2008
- Impaired Mitochondrial Activity in the Insulin-Resistant Offspring of Patients with Type 2 DiabetesNew England Journal of Medicine, 2004
- An analysis of the effects of short T2 values on the hyperbolic-secant pulseJournal of Magnetic Resonance (1969), 1991
- Saturation-transfer studies of ATP-Pi exchange in isolated perfused rat liverBiochimica et Biophysica Acta (BBA) - Bioenergetics, 1987
- Magnetization-transfer measurements of individual rate constants in the presence of multiple reactionsJournal of Magnetic Resonance (1969), 1985
- Investigation of peptide bond isomerization by magnetization transfer NMRJournal of Magnetic Resonance (1969), 1977