Thermal induced deflection in atomic force microscopy cantilevers: analysis & solution
Open Access
- 25 August 2023
- journal article
- research article
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (12) , 125013
Abstract
Atomic force microscopy (AFM) cantilevers are commonly made from two material layers: a reflective coating and structural substrate. Although effective, this can result in thermally induced cantilever deflection due to ambient and local temperature changes. While this has been previously documented, key aspects of this common phenomenon have been overlooked. This work explores the impact of thermally induced cantilever deflection when in- and out-of-contact, including the topographic scan artefacts produced. Scanning thermal microscopy probes were employed to provide direct cantilever temperature measurement from Peltier and microheater sources, whilst permitting cantilever deflection to be simultaneously monitored. Optical lever-based measurements of thermal deflection in the AFM were found to vary by up to 250% depending on the reflected laser spot location on the cantilever. This highlights AFM’s inherent inability to correctly measure and account for thermal induced cantilever deflection in its feedback system. This is particularly problematic when scanning a tip in-contact with the surface, when probe behaviour is closer mechanically to that of a bridge than a cantilever regarding thermal bending. In this case, measurements of cantilever deflection and inferred surface topography contained significant artefacts and varied from negative to positive for different optical lever laser locations on the cantilevers. These topographic errors were measured to be up to 600 nm for a small temperature change of 2 K. However, all cantilevers measured showed a point of consistent, complete thermal deflection insensitivity 55% to 60% along their lengths. Positioning the reflected laser at this location, AFM scans exhibited improvements of up-to 97% in thermal topographic artefacts relative to other laser positions.Keywords
Funding Information
- Engineering and Physical Sciences Research Council
This publication has 32 references indexed in Scilit:
- Calibration of atomic force microscope cantilevers using standard and inverted static methods assisted by FIB-milled spatial markersNanotechnology, 2012
- High temperature imaging using a thermally compensated cantilever resistive probe for scanning thermal microscopyJournal of Vacuum Science & Technology B, 2011
- Interlaboratory round robin on cantilever calibration for AFM force spectroscopyUltramicroscopy, 2011
- Thermal drift study on different commercial scanning probe microscopes during the initial warming-up phaseMeasurement Science and Technology, 2011
- Force calibration in lateral force microscopy: a review of the experimental methodsJournal of Physics D: Applied Physics, 2010
- Fast technique for AFM vertical drift compensationMeasurement Science and Technology, 2007
- Reducing probe dependent drift in atomic force microscope with symmetrically supported torsion leversReview of Scientific Instruments, 2006
- Comment on Tilt of Atomic Force Microscope Cantilevers: Effect on Spring Constant and Adhesion MeasurementsLangmuir, 2005
- A review of atomic force microscopy imaging systems: application to molecular metrology and biological sciencesMechatronics, 2004
- Effects of temperature and pressure on microcantilever resonance responseUltramicroscopy, 2003