Jonathan M. R. Weaver
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jonathan M. R. Weaver has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Charalambos Evangeli
Department of Materials, University of Oxford, Oxford OX1 3PH, United Kingdom
1 shared publication - Jean Spièce
Institute of Condensed Matter and Nanosciences Université Catholique de Louvain (UCLouvain) 1348 Louvain‐la‐Neuve Belgium
1 shared publication Jonathan M R Weaver
James Watt School of Engineering, University of Glasgow, Glasgow, United Kingdom
1 shared publication- Pascal Gehring
Institute of Condensed Matter and Nanosciences Université Catholique de Louvain (UCLouvain) 1348 Louvain‐la‐Neuve Belgium
1 shared publication Phil S. Dobson
James Watt School of Engineering University of Glasgow Glasgow G12 8LT UK
1 shared publication- Phillip S Dobson
James Watt School of Engineering, University of Glasgow, Glasgow, United Kingdom
1 shared publication
Latest Publications
- 17 March 2025
- Published by Wiley in Small Methods
- Vol. 9 (5) , e2401715
Direct Measurement of the Local Electrocaloric Effect in 2D α‐In 2 Se 3 by Scanning Electrocaloric Thermometry
The electrocaloric effect refers to the temperature change in a material when an electric field is applied or removed. Significant breakthroughs revealed its potential for solid‐state cooling technologies in past decades. These devices offer a sustainable alternative to traditional vapor compression refrigeration, with advantages such as compactness, silent operation, and the absence of moving parts or refrigerants. Electrocaloric effects are typically studied using indirect methods based on polarization data, which suffer from inaccuracies related to assumptions about heat capacity. Direct methods, although more precise, require device fabrication and face challenges in studying meso‐ or nanoscale systems, like 2D materials, and materials with non‐uniform polarization textures where high spatial resolution is required. In this study, a novel technique, Scanning Electrocaloric Thermometry, is introduced for characterizing the local electrocaloric effect in nanomaterials. This approach achieves high spatial resolution by locally applying electric fields and by simultaneously measuring the resulting temperature change. By employing AC excitation, the measurement sensitivity is further enhanced and the electrocaloric effect is disentangled from other heating mechanisms such as Joule heating and dielectric losses. The effectiveness of the method is demonstrated by examining electrocaloric and heat dissipation phenomena in 2D In 2 Se 3 micrometer‐sized flakes poly(vinylidene fluoride‐trifluoroethylene) films.
- 17 March 2025
- Published by Wiley in Small Methods
- Vol. 9 (5) , e2401715
Direct Measurement of the Local Electrocaloric Effect in 2D α‐In 2 Se 3 by Scanning Electrocaloric Thermometry
The electrocaloric effect refers to the temperature change in a material when an electric field is applied or removed. Significant breakthroughs revealed its potential for solid‐state cooling technologies in past decades. These devices offer a sustainable alternative to traditional vapor compression refrigeration, with advantages such as compactness, silent operation, and the absence of moving parts or refrigerants. Electrocaloric effects are typically studied using indirect methods based on polarization data, which suffer from inaccuracies related to assumptions about heat capacity. Direct methods, although more precise, require device fabrication and face challenges in studying meso‐ or nanoscale systems, like 2D materials, and materials with non‐uniform polarization textures where high spatial resolution is required. In this study, a novel technique, Scanning Electrocaloric Thermometry, is introduced for characterizing the local electrocaloric effect in nanomaterials. This approach achieves high spatial resolution by locally applying electric fields and by simultaneously measuring the resulting temperature change. By employing AC excitation, the measurement sensitivity is further enhanced and the electrocaloric effect is disentangled from other heating mechanisms such as Joule heating and dielectric losses. The effectiveness of the method is demonstrated by examining electrocaloric and heat dissipation phenomena in 2D In 2 Se 3 micrometer‐sized flakes poly(vinylidene fluoride‐trifluoroethylene) films.
- Open Access
- 25 August 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (12) , 125013
Thermal induced deflection in atomic force microscopy cantilevers: analysis & solution
Atomic force microscopy (AFM) cantilevers are commonly made from two material layers: a reflective coating and structural substrate. Although effective, this can result in thermally induced cantilever deflection due to ambient and local temperature changes. While this has been previously documented, key aspects of this common phenomenon have been overlooked. This work explores the impact of thermally induced cantilever deflection when in- and out-of-contact, including the topographic scan artefacts produced. Scanning thermal microscopy probes were employed to provide direct cantilever temperature measurement from Peltier and microheater sources, whilst permitting cantilever deflection to be simultaneously monitored. Optical lever-based measurements of thermal deflection in the AFM were found to vary by up to 250% depending on the reflected laser spot location on the cantilever. This highlights AFM’s inherent inability to correctly measure and account for thermal induced cantilever deflection in its feedback system. This is particularly problematic when scanning a tip in-contact with the surface, when probe behaviour is closer mechanically to that of a bridge than a cantilever regarding thermal bending. In this case, measurements of cantilever deflection and inferred surface topography contained significant artefacts and varied from negative to positive for different optical lever laser locations on the cantilevers. These topographic errors were measured to be up to 600 nm for a small temperature change of 2 K. However, all cantilevers measured showed a point of consistent, complete thermal deflection insensitivity 55% to 60% along their lengths. Positioning the reflected laser at this location, AFM scans exhibited improvements of up-to 97% in thermal topographic artefacts relative to other laser positions.
- 25 August 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (12) , 125013
Open AccessThermal induced deflection in atomic force microscopy cantilevers: analysis & solution
Atomic force microscopy (AFM) cantilevers are commonly made from two material layers: a reflective coating and structural substrate. Although effective, this can result in thermally induced cantilever deflection due to ambient and local temperature changes. While this has been previously documented, key aspects of this common phenomenon have been overlooked. This work explores the impact of thermally induced cantilever deflection when in- and out-of-contact, including the topographic scan artefacts produced. Scanning thermal microscopy probes were employed to provide direct cantilever temperature measurement from Peltier and microheater sources, whilst permitting cantilever deflection to be simultaneously monitored. Optical lever-based measurements of thermal deflection in the AFM were found to vary by up to 250% depending on the reflected laser spot location on the cantilever. This highlights AFM’s inherent inability to correctly measure and account for thermal induced cantilever deflection in its feedback system. This is particularly problematic when scanning a tip in-contact with the surface, when probe behaviour is closer mechanically to that of a bridge than a cantilever regarding thermal bending. In this case, measurements of cantilever deflection and inferred surface topography contained significant artefacts and varied from negative to positive for different optical lever laser locations on the cantilevers. These topographic errors were measured to be up to 600 nm for a small temperature change of 2 K. However, all cantilevers measured showed a point of consistent, complete thermal deflection insensitivity 55% to 60% along their lengths. Positioning the reflected laser at this location, AFM scans exhibited improvements of up-to 97% in thermal topographic artefacts relative to other laser positions.