A Patient-Specific Closed-Loop Epilepsy Management SoC With One-Shot Learning and Online Tuning
Open Access
- 4 February 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 57 (4) , 1049-1060
Abstract
Epilepsy treatment in clinical practices with surface electroencephalogram (EEG) often faces training dataset shortage issue, which is aggravated by seizure pattern variation among patients. To facilitate future optimization of the detection accuracy as new datasets are available, a fully programmable patient-specific closed-loop epilepsy tracking and suppression system-on-chip (SoC) is proposed with the first-in-literature one-shot learning and online tuning to the best of our knowledge. The proposed two-cycle analog front end (2C-AFE) obtains a 9.8-b effective number of bits (ENOB) with 8 $\times $ capacitive digital-to-analog converter (CAPDAC) area reduction and 4 $\times $ switching energy saving compared to a conventional 10-b SAR with an identical unit capacitor size. The entire SoC with 16 surface EEG recording channels consumes an ultra-low energy of 0.97 $\mu \text{J}$ /class and occupies a miniaturized area of 0.13 mm 2 /ch. in 40-nm CMOS, achieving real-time concurrent seizure detection and raw EEG recording. Verified with the CHB-MIT database, the guided time–channel averaging (GTCA) neural processor achieves the vector-based sensitivity, the specificity, and the latency of 97.8%, 99.5%, and < 1 s, respectively. The initial one-shot learning and follow-up online tuning function is validated with the EEG recording from a local hospital patient, which demonstrates a 1.8 $\times $ vector-based sensitivity boost.
Keywords
Funding Information
- Agency for Science, Technology and Research (A*STAR), Singapore, Advanced Manufacturing and Engineering (AME) Nanosystems at the Edge Program (A18A4b0055)
- National University of Singapore (R-263-000-C62-133/731)
This publication has 35 references indexed in Scilit:
- A 5 GS/s 150 mW 10 b SHA-Less Pipelined/SAR Hybrid ADC for Direct-Sampling Systems in 28 nm CMOSIEEE Journal of Solid-State Circuits, 2015
- A 1.83 $\mu$J/Classification, 8-Channel, Patient-Specific Epileptic Seizure Classification SoC Using a Non-Linear Support Vector MachineIEEE Transactions on Biomedical Circuits and Systems, 2015
- A 1 GS/s 10b 18.9 mW Time-Interleaved SAR ADC With Background Timing Skew CalibrationIEEE Journal of Solid-State Circuits, 2014
- A 1.83µJ/classification nonlinear support-vector-machine-based patient-specific seizure classification SoC2013
- Automatic seizure detection in SEEG using high frequency activities in wavelet domainMedical Engineering & Physics, 2012
- Analysis of Electroencephalography (EEG) Signals and Its Categorization–A StudyProcedia Engineering, 2012
- A 26 $\mu$W 8 bit 10 MS/s Asynchronous SAR ADC for Low Energy RadiosIEEE Journal of Solid-State Circuits, 2011
- Toward rational design of electrical stimulation strategies for epilepsy controlEpilepsy & Behavior, 2010
- Non-rectangular waveforms for neural stimulation with practical electrodesJournal of Neural Engineering, 2007
- Advances in Quantitative Electroencephalogram Analysis MethodsAnnual Review of Biomedical Engineering, 2004