A ratiometric fluorescent metal ion indicator based on dansyl labeled poly(N-isopropylacrylamide) responds to a quenching metal ion
- 18 October 2011
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 136 (23) , 5006-5011
Abstract
The fluorescence emission of poly(N-isopropylacrylamide) (PNIPAM) covalently tagged with a 5-(dimethylamino)naphthalene-1-sulfonyl (dansyl) fluorophore and an iminodiacetic acid (IDA) chelator changes with temperature and with Cu(II) complexation. Increasing the temperature above the lower critical solution temperature (LCST) causes the polymer to collapse from a coil to a compact globule. This changes the environment experienced by the fluorophore causing a shift in maximum emission wavelength from 546 to 508 nm and an increase in the ratio of emission intensity at 508 nm to emission intensity at 546 nm from 0.70 to almost 1.40. Metal ions can be sensed by working at a temperature where the uncomplexed polymer is in an expanded state due to the charges on the ligand. Complexation with a metal ion such as Cu(II) neutralizes the charges on the ligand causing the polymer to collapse. At 35 °C, the emission intensity maximum shifted from 535 to 510 nm as Cu(II) concentration was increased and the intensity ratio increased from 0.84 to 1.28. By decoupling complexation from fluorescence, we have prepared a ratiometric fluorescent indicator for a metal ion that normally quenches fluorescence. The affinity for Cu(II) was found to be thermally tunable. The log apparent formation constants for the indicator-Cu(II) complex were estimated as the half way point in the intensity ratio vs. pCu curve. The values were determined to be 4.3 at 35 °C and 3.2 at 34 °C respectively.Keywords
This publication has 36 references indexed in Scilit:
- BODIPY-Conjugated Thermoresponsive Copolymer as a Fluorescent Thermometer Based on Polymer MicroviscosityLangmuir, 2009
- Enhancing Detection Sensitivity of Responsive Microgel-Based Cu(II) Chemosensors via Thermo-Induced Volume Phase TransitionsChemistry of Materials, 2009
- Synthetic fluorescent sensors for studying the cell biology of metalsNature Chemical Biology, 2008
- Fluorogenic Ion Sensing System Working in Water, Based on Stimulus-Responsive Copolymers Incorporating a Polarity-Sensitive FluorophoreMacromolecules, 2007
- Calcium Green FlAsH as a genetically targeted small-molecule calcium indicatorNature Chemical Biology, 2007
- Swellable theophylline selective microparticles for sensing applicationsThe Analyst, 2007
- Divalent metal ion-sensitive holographic sensorsAnalytica Chimica Acta, 2005
- Determination of the chemical speciation of trace metals in aqueous systems by the Wageningen Donnan Membrane TechniqueAnalytica Chimica Acta, 2000
- A fluorescent sensor for Cu2+ at the sub-ppm levelJournal of Photochemistry and Photobiology A: Chemistry, 1998
- Chelating resins: Sorption characteristics in chloride mediaJournal of Radioanalytical and Nuclear Chemistry, 1997