WSW. Rudolf Seitz

W. Rudolf Seitz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


W. Rudolf Seitz has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Sensors Best Paper Award 2015

    by Vittorio M.N. Passaro, W. Rudolf Seitz, Assefa M. Melesse, Alexander Star, Leonhard Reindl

    Since 2011, an annual award system was instituted to recognize outstanding Sensors papers that are related to sensing technologies and applications and meet the aims, scope and high standards of this journal [1–4]. This year, the winners were chosen by the Section Editor-in-Chiefs of Sensors from among all the papers published in 2011 to track citations. Reviews and full research articles were considered separately. We gladly announce that the following eight papers were awarded the Sensors Best Paper Award in 2015.

  • Open Access

    Sensors Best Paper Award 2014

    by Vittorio M. N. Passaro, W. Rudolf Seitz, Assefa M. Melesse, Alexander Star, Mohamed F. Younis

    In 2011, an annual award system was instituted to recognize outstanding Sensors papers that are related to sensing technologies and applications and meet the aims, scope and high standards of this journal [1–3]. This year, nominations were made by the Section Editor-in-Chiefs of Sensors from among all the papers published in 2010 to track citations. Reviews and full research articles were considered separately.


  • Open Access

    Sensors Best Paper Award 2013

    by Vittorio M.N. Passaro, W. Rudolf Seitz, Assefa M. Melesse, Alexander Star, Ophelia Han

    Since 2011, Sensors has instituted an annual award to recognize outstanding papers that are related to sensing technologies and applications and meet the aims, scope and high standards of this journal [1,2].


  • Open Access

    Fluorescent Ratiometric Indicators Based on Cu(II)-Induced Changes in Poly(NIPAM) Microparticle Volume

    by John Osambo, W. Rudolf Seitz, Daniel P. Kennedy, Roy P. Planalp, Aaron M. Jones, Randy K. Jackson, Shawn Burdette

    Microparticles consisting of the thermal responsive polymer N-isopropyl acrylamide (polyNIPAM), a metal ion-binding ligand and a fluorophore pair that undergoes fluorescence resonance energy transfer (FRET) have been prepared and characterized. Upon the addition of Cu(II), the microparticles swell or contract depending on whether charge is introduced or neutralized on the polymer backbone. The variation in microparticle morphology is translated into changes in emission of each fluorophore in the FRET pair. By measuring the emission intensity ratio between the FRET pair upon Cu(II) addition, the concentration of metal ion in solution can be quantified. This ratiometric fluorescent indicator is the newest technique in an ongoing effort to use emission spectroscopy to monitor Cu(II) thermodynamic activity in environmental water samples.


  • A ratiometric fluorescent metal ion indicator based on dansyl labeled poly(N-isopropylacrylamide) responds to a quenching metal ion

    by Jie Du, Shaojun Yao, W. Rudolf Seitz, Nicholas E. Bencivenga, Justin O. Massing, Roy P. Planalp, Randy K. Jackson, Daniel P. Kennedy, Shawn C. Burdette

    The fluorescence emission of poly(N-isopropylacrylamide) (PNIPAM) covalently tagged with a 5-(dimethylamino)naphthalene-1-sulfonyl (dansyl) fluorophore and an iminodiacetic acid (IDA) chelator changes with temperature and with Cu(II) complexation. Increasing the temperature above the lower critical solution temperature (LCST) causes the polymer to collapse from a coil to a compact globule. This changes the environment experienced by the fluorophore causing a shift in maximum emission wavelength from 546 to 508 nm and an increase in the ratio of emission intensity at 508 nm to emission intensity at 546 nm from 0.70 to almost 1.40. Metal ions can be sensed by working at a temperature where the uncomplexed polymer is in an expanded state due to the charges on the ligand. Complexation with a metal ion such as Cu(II) neutralizes the charges on the ligand causing the polymer to collapse. At 35 °C, the emission intensity maximum shifted from 535 to 510 nm as Cu(II) concentration was increased and the intensity ratio increased from 0.84 to 1.28. By decoupling complexation from fluorescence, we have prepared a ratiometric fluorescent indicator for a metal ion that normally quenches fluorescence. The affinity for Cu(II) was found to be thermally tunable. The log apparent formation constants for the indicator-Cu(II) complex were estimated as the half way point in the intensity ratio vs. pCu curve. The values were determined to be 4.3 at 35 °C and 3.2 at 34 °C respectively.