Early, accurate, and bulk detection of respiratory pathogens is essential for patient management and infection control. STARlet-All-in-One System (AIOS) (Seegene) is a new, fully automated, sample-to-result, molecular diagnostic platform. This study describes the first evaluation of STARlet-AIOS, by testing the Allplex™ SARS-CoV-2 (AS) and Allplex™ SARS-CoV-2/FluA/FluB/RSV combination (AC) assays in comparison to the SARS-CoV-2 assays used at our institute. Over a 3-week period, all naso-/oropharyngeal specimens tested for SARS-CoV-2 using either GeneXpert, Panther, or in-house developed test (LDT) were tested on the AIOS using the AS or AC assays. In addition, retrospective cohorts of specimens containing SARS-CoV-2, influenza virus A, influenza virus B, and RSV were tested. Discrepant results were re-tested with another assay used in this study. Hands-on time (HOT) and turn-around time (TAT) of the different systems were monitored and compared. A total of 738 specimens were tested on the AIOS using the AS assay. In addition, 210 specimens were tested using the AC assay. Overall agreement for SARS-CoV-2 detection was established as 98.5% and 95.2% for the AS and AC assay, respectively. Retrospective testing revealed high agreements for all targets, except for influenza virus A (agreement of 87.5%). HOT of the system was comparable to the HOT of GeneXpert and Panther and TAT comparable to Panther and LDT. The AIOS proved to be a robust sample-to-result system with low HOT and moderate TAT. This study showed reliable detection of SARS-CoV-2, influenza virus B, and RSV, whereas detection of influenza virus A using the AC assay appeared to be suboptimal.Keywords
This publication has 12 references indexed in Scilit:
- Comparison of the Clinical Performance of the Point-of-care STANDARD M10 SARS-CoV-2 and Xpert Xpress SARS-CoV-2 AssaysAnnals of Laboratory Medicine, 2022
- Comparison of three molecular diagnostic assays for SARS‐CoV‐2 detection: Evaluation of analytical sensitivity and clinical performanceJournal of Clinical Laboratory Analysis, 2022
- Real-Life Head-to-Head Comparison of Performance of Two High-Throughput Automated Assays for the Detection of SARS-CoV-2 RNA in Nasopharyngeal SwabsThe Journal of Molecular Diagnostics, 2021
- Assay System for Simultaneous Detection of SARS-CoV-2 and Other Respiratory VirusesDiagnostics, 2021
- Variable Sensitivity of SARS-CoV-2 Molecular Detection in European Expert Laboratories: External Quality Assessment, June and July 2020Journal of Clinical Microbiology, 2021
- Evaluation of Three Multiplex Real-time Reverse Transcription PCR Assays for Simultaneous Detection of SARS-CoV-2, Influenza A/B, and Respiratory Syncytial Virus in Nasopharyngeal SwabsJournal of Korean Medical Science, 2021
- Low prevalence of SARS-CoV-2 in plasma of COVID-19 patients presenting to the emergency departmentJournal of Clinical Virology, 2020
- Evaluation of the QIAstat-Dx Respiratory SARS-CoV-2 Panel, the First Rapid Multiplex PCR Commercial Assay for SARS-CoV-2 DetectionJournal of Clinical Microbiology, 2020
- Comparison of seven commercial RT-PCR diagnostic kits for COVID-19Journal of Clinical Virology, 2020
- Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCREurosurveillance, 2020