Roel H. T. Nijhuis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Roel H. T. Nijhuis has a total of 267 co-authors. Here are the top co-authors by number of shared publications:
- Eric C. J. Claas
Leiden University Medical Center
3 shared publications A. Russcher
Laboratory for Medical Microbiology and Medical Immunology, Meander Medical Center, Amersfoort, the Netherlands
2 shared publicationsA.A. van Zwet
Department of Medical Microbiology and Medical Immunology, Rijnstate, Velp, The Netherlands
2 shared publicationsA.E. Smilde
Meander Med Ctr, Dept Hyg & Infect Prevent, Amersfoort, Netherlands
2 shared publicationsA.J.L. Weersink
Meander Med Ctr, Lab Med Microbiol & Med Immunol, Maatweg 3, NL-3813 TZ Amersfoort, Netherlands
2 shared publicationsAnton van Zwet
2 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by Wiley in Obstetrics and Gynecology International
- Vol. 2026 (1) , 3810643
Limited Role of Mycoplasma genitalium, Chlamydia trachomatis , and Neisseria gonorrhoeae in Pelvic Inflammatory Disease and Tubo‐Ovarian Abscess in the Netherlands: A Multicenter Prospective Cohort Study
Objective: To evaluate the role of Mycoplasma genitalium , Chlamydia trachomatis , and Neisseria gonorrhoeae in pelvic inflammatory disease (PID) and tubo‐ovarian abscess (TOA), and to assess the effectiveness of standard therapy in achieving clinical and microbiological cure. Design: Multicenter prospective cohort study. Setting: Three hospitals and one Centre for Sexual Health (CSH) in the Netherlands. Population: Women ≥ 18 years with clinically diagnosed PID and/or TOA between 2021 and 2023. Methods: Clinical examination, C‐reactive protein (CRP) levels, and vaginal swabs were evaluated at baseline and follow‐up. Participants completed a self‐reported symptom diary. Antibiotic therapy was prescribed in accordance with Dutch national hospital and CSH guidelines. Main Outcome Measures: The primary outcome, clinical cure at Week 4, was defined as the absence of fever and vomiting, CRP < 10 mg/L, and ≥ 70% reduction in symptom score. Microbiological cure was the secondary outcome. Results: Among 100 women with PID and/or TOA, monoinfections with M. genitalium, C. trachomatis , and N. gonorrhoeae were detected in 4.0%, 6.0%, and 9.0% of cases, respectively; coinfections occurred in 4.0%, while 77.0% tested negative for all three pathogens. By Week 4, M. genitalium and C. trachomatis were cleared, with one case of persistent or recurrent N. gonorrhoeae . Symptom scores declined by 91.3%, with significant CRP reduction. Clinical cure was achieved in 67.3% of participants, with no association between cure and sexually transmitted infection (STI) status or diagnosis. Conclusions: Most PID and/or TOA cases lacked an identifiable STI etiology. Nonetheless, the majority showed clinical and microbiological cure, supporting current empiric treatment.
- 1 January 2026
- Published by Wiley in Obstetrics and Gynecology International
- Vol. 2026 (1) , 3810643
Open AccessLimited Role of Mycoplasma genitalium, Chlamydia trachomatis , and Neisseria gonorrhoeae in Pelvic Inflammatory Disease and Tubo‐Ovarian Abscess in the Netherlands: A Multicenter Prospective Cohort Study
Objective: To evaluate the role of Mycoplasma genitalium , Chlamydia trachomatis , and Neisseria gonorrhoeae in pelvic inflammatory disease (PID) and tubo‐ovarian abscess (TOA), and to assess the effectiveness of standard therapy in achieving clinical and microbiological cure. Design: Multicenter prospective cohort study. Setting: Three hospitals and one Centre for Sexual Health (CSH) in the Netherlands. Population: Women ≥ 18 years with clinically diagnosed PID and/or TOA between 2021 and 2023. Methods: Clinical examination, C‐reactive protein (CRP) levels, and vaginal swabs were evaluated at baseline and follow‐up. Participants completed a self‐reported symptom diary. Antibiotic therapy was prescribed in accordance with Dutch national hospital and CSH guidelines. Main Outcome Measures: The primary outcome, clinical cure at Week 4, was defined as the absence of fever and vomiting, CRP < 10 mg/L, and ≥ 70% reduction in symptom score. Microbiological cure was the secondary outcome. Results: Among 100 women with PID and/or TOA, monoinfections with M. genitalium, C. trachomatis , and N. gonorrhoeae were detected in 4.0%, 6.0%, and 9.0% of cases, respectively; coinfections occurred in 4.0%, while 77.0% tested negative for all three pathogens. By Week 4, M. genitalium and C. trachomatis were cleared, with one case of persistent or recurrent N. gonorrhoeae . Symptom scores declined by 91.3%, with significant CRP reduction. Clinical cure was achieved in 67.3% of participants, with no association between cure and sexually transmitted infection (STI) status or diagnosis. Conclusions: Most PID and/or TOA cases lacked an identifiable STI etiology. Nonetheless, the majority showed clinical and microbiological cure, supporting current empiric treatment.
- 2 April 2025
- Published by Oxford University Press (OUP) in Medical Mycology
- Vol. 63 (4)
Evaluation of five real-time PCR assays for the detection of Candidozyma auris in clinical specimens
Candidozyma auris is notorious for its association with invasive infections and hospital outbreaks. Trying to prevent introduction in the hospital, settings are implementing screening procedures including the best diagnostic procedure. In the Netherlands, nucleic acid amplification testing is recommended for this purpose. In this study, we performed a head-to-head comparison of five different real-time PCR assays for the detection of C. auris. The evaluated assays include the CandidaGenius (Pathonostics), C. auris Detection Kit (Revvity), AurisID (Olm), AltoStar C. auris 1.5 (Altona), and Erasmus Medical Center (EMC) assay (lab-developed test). Analytical evaluation was conducted by assessing selectivity, analytical specificity, reproducibility, and limit of detection (LoD). Subsequently, a clinical evaluation was performed by testing 45 (spiked) clinical specimens. Additionally, all available specimens from a C. auris-colonized patient were tested. The analytical evaluation demonstrated excellent selectivity and specificity for all assays, high reproducibility for most assays, and an excellent LoD for all assays except the Revvity assay. The clinical validation showed excellent sensitivity (100%), high specificity (≥97.8%), and a LoD ranging from 0.3 to 1.8 CFU/PCR for all assays. Fourteen specimens from the colonized patient were tested, of which six, five, and three specimens tested positive using the AltoStar C. auris 1.5, EMC assay, and CandidaGenius, respectively. The results of this evaluation showed that AurisID, AltoStar C. auris 1.5, and the EMC assay performed equally well. All three assays are PCR reagent-only assays that can be easily implemented as screening PCRs to detect C. auris in clinical specimens.
- 2 April 2025
- Published by Oxford University Press (OUP) in Medical Mycology
- Vol. 63 (4)
Evaluation of five real-time PCR assays for the detection of Candidozyma auris in clinical specimens
Candidozyma auris is notorious for its association with invasive infections and hospital outbreaks. Trying to prevent introduction in the hospital, settings are implementing screening procedures including the best diagnostic procedure. In the Netherlands, nucleic acid amplification testing is recommended for this purpose. In this study, we performed a head-to-head comparison of five different real-time PCR assays for the detection of C. auris. The evaluated assays include the CandidaGenius (Pathonostics), C. auris Detection Kit (Revvity), AurisID (Olm), AltoStar C. auris 1.5 (Altona), and Erasmus Medical Center (EMC) assay (lab-developed test). Analytical evaluation was conducted by assessing selectivity, analytical specificity, reproducibility, and limit of detection (LoD). Subsequently, a clinical evaluation was performed by testing 45 (spiked) clinical specimens. Additionally, all available specimens from a C. auris-colonized patient were tested. The analytical evaluation demonstrated excellent selectivity and specificity for all assays, high reproducibility for most assays, and an excellent LoD for all assays except the Revvity assay. The clinical validation showed excellent sensitivity (100%), high specificity (≥97.8%), and a LoD ranging from 0.3 to 1.8 CFU/PCR for all assays. Fourteen specimens from the colonized patient were tested, of which six, five, and three specimens tested positive using the AltoStar C. auris 1.5, EMC assay, and CandidaGenius, respectively. The results of this evaluation showed that AurisID, AltoStar C. auris 1.5, and the EMC assay performed equally well. All three assays are PCR reagent-only assays that can be easily implemented as screening PCRs to detect C. auris in clinical specimens.
- 6 November 2024
- Published by Elsevier in Journal of Hospital Infection
- Vol. 155, 192-197
Analysis of a persistent outbreak with vancomycin-resistant Enterococcus faecium revealed the need for an adapted diagnostic algorithm
- 6 November 2024
- Published by Elsevier in Journal of Hospital Infection
- Vol. 155, 192-197
Analysis of a persistent outbreak with vancomycin-resistant Enterococcus faecium revealed the need for an adapted diagnostic algorithm
- 25 July 2024
- Published by Springer Nature in European Journal of Clinical Microbiology & Infectious Diseases
- Vol. 43 (10) , 2065-2066
Comparison of diagnostic sensitivity using lower and upper respiratory tract specimens by molecular detection of Mycoplasma pneumoniae
- 25 July 2024
- Published by Springer Nature in European Journal of Clinical Microbiology & Infectious Diseases
- Vol. 43 (10) , 2065-2066
Comparison of diagnostic sensitivity using lower and upper respiratory tract specimens by molecular detection of Mycoplasma pneumoniae
- Open Access
- 28 March 2024
- Published by Oxford University Press (OUP) in The Journal of Infectious Diseases
- Vol. 230 (4) , e917-e928
Epidemiological and Clinical Insights into the Enterovirus D68 Upsurge in Europe 2021–2022 and Emergence of Novel B3-Derived Lineages, ENPEN Multicentre Study
Enterovirus D68 (EV-D68) infections are associated with severe respiratory disease and acute flaccid myelitis (AFM). The European Non-Polio Enterovirus Network (ENPEN) aimed to investigate the epidemiological and genetic characteristics of EV-D68 infections and its clinical impact during the fall-winter season of 2021–2022. From 19 European countries, 58 institutes reported 10 481 (6.8%) EV-positive samples of which 1004 (9.6%) were identified as EV-D68 (including 852 respiratory samples). Clinical data were reported for 969 cases; 78.9% of infections were reported in children (0–5 years); and 37.9% of cases were hospitalized. Acute respiratory distress was commonly noted (93.1%) followed by fever (49.4%). Neurological problems were observed in 6.4% of cases including 6 diagnosed with AFM. Phylodynamic/Nextstrain and phylogenetic analyses based on 694 sequences showed the emergence of 2 novel B3-derived lineages, with no regional clustering. In conclusion, we describe a large-scale European EV-D68 upsurge with severe clinical impact and the emergence of B3-derived lineages.
- 28 March 2024
- Published by Oxford University Press (OUP) in The Journal of Infectious Diseases
- Vol. 230 (4) , e917-e928
Open AccessEpidemiological and Clinical Insights into the Enterovirus D68 Upsurge in Europe 2021–2022 and Emergence of Novel B3-Derived Lineages, ENPEN Multicentre Study
Enterovirus D68 (EV-D68) infections are associated with severe respiratory disease and acute flaccid myelitis (AFM). The European Non-Polio Enterovirus Network (ENPEN) aimed to investigate the epidemiological and genetic characteristics of EV-D68 infections and its clinical impact during the fall-winter season of 2021–2022. From 19 European countries, 58 institutes reported 10 481 (6.8%) EV-positive samples of which 1004 (9.6%) were identified as EV-D68 (including 852 respiratory samples). Clinical data were reported for 969 cases; 78.9% of infections were reported in children (0–5 years); and 37.9% of cases were hospitalized. Acute respiratory distress was commonly noted (93.1%) followed by fever (49.4%). Neurological problems were observed in 6.4% of cases including 6 diagnosed with AFM. Phylodynamic/Nextstrain and phylogenetic analyses based on 694 sequences showed the emergence of 2 novel B3-derived lineages, with no regional clustering. In conclusion, we describe a large-scale European EV-D68 upsurge with severe clinical impact and the emergence of B3-derived lineages.
- 15 November 2023
- Published by Springer Nature in European Journal of Clinical Microbiology & Infectious Diseases
- Vol. 43 (1) , 87-93
Evaluation of the fully automated, sample-to-result Seegene STARlet-AIOS platform for detection of SARS-CoV-2, influenza virus A, influenza virus B, and RSV
Early, accurate, and bulk detection of respiratory pathogens is essential for patient management and infection control. STARlet-All-in-One System (AIOS) (Seegene) is a new, fully automated, sample-to-result, molecular diagnostic platform. This study describes the first evaluation of STARlet-AIOS, by testing the Allplex™ SARS-CoV-2 (AS) and Allplex™ SARS-CoV-2/FluA/FluB/RSV combination (AC) assays in comparison to the SARS-CoV-2 assays used at our institute. Over a 3-week period, all naso-/oropharyngeal specimens tested for SARS-CoV-2 using either GeneXpert, Panther, or in-house developed test (LDT) were tested on the AIOS using the AS or AC assays. In addition, retrospective cohorts of specimens containing SARS-CoV-2, influenza virus A, influenza virus B, and RSV were tested. Discrepant results were re-tested with another assay used in this study. Hands-on time (HOT) and turn-around time (TAT) of the different systems were monitored and compared. A total of 738 specimens were tested on the AIOS using the AS assay. In addition, 210 specimens were tested using the AC assay. Overall agreement for SARS-CoV-2 detection was established as 98.5% and 95.2% for the AS and AC assay, respectively. Retrospective testing revealed high agreements for all targets, except for influenza virus A (agreement of 87.5%). HOT of the system was comparable to the HOT of GeneXpert and Panther and TAT comparable to Panther and LDT. The AIOS proved to be a robust sample-to-result system with low HOT and moderate TAT. This study showed reliable detection of SARS-CoV-2, influenza virus B, and RSV, whereas detection of influenza virus A using the AC assay appeared to be suboptimal.
- 15 November 2023
- Published by Springer Nature in European Journal of Clinical Microbiology & Infectious Diseases
- Vol. 43 (1) , 87-93
Evaluation of the fully automated, sample-to-result Seegene STARlet-AIOS platform for detection of SARS-CoV-2, influenza virus A, influenza virus B, and RSV
Early, accurate, and bulk detection of respiratory pathogens is essential for patient management and infection control. STARlet-All-in-One System (AIOS) (Seegene) is a new, fully automated, sample-to-result, molecular diagnostic platform. This study describes the first evaluation of STARlet-AIOS, by testing the Allplex™ SARS-CoV-2 (AS) and Allplex™ SARS-CoV-2/FluA/FluB/RSV combination (AC) assays in comparison to the SARS-CoV-2 assays used at our institute. Over a 3-week period, all naso-/oropharyngeal specimens tested for SARS-CoV-2 using either GeneXpert, Panther, or in-house developed test (LDT) were tested on the AIOS using the AS or AC assays. In addition, retrospective cohorts of specimens containing SARS-CoV-2, influenza virus A, influenza virus B, and RSV were tested. Discrepant results were re-tested with another assay used in this study. Hands-on time (HOT) and turn-around time (TAT) of the different systems were monitored and compared. A total of 738 specimens were tested on the AIOS using the AS assay. In addition, 210 specimens were tested using the AC assay. Overall agreement for SARS-CoV-2 detection was established as 98.5% and 95.2% for the AS and AC assay, respectively. Retrospective testing revealed high agreements for all targets, except for influenza virus A (agreement of 87.5%). HOT of the system was comparable to the HOT of GeneXpert and Panther and TAT comparable to Panther and LDT. The AIOS proved to be a robust sample-to-result system with low HOT and moderate TAT. This study showed reliable detection of SARS-CoV-2, influenza virus B, and RSV, whereas detection of influenza virus A using the AC assay appeared to be suboptimal.
- Open Access
- 28 April 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (4) , e0267605
Haemostatic differences between SARS-CoV-2 PCR-positive and negative patients at the time of hospital admission
Coronavirus disease 2019 (COVID-19), caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is associated with thrombosis. We conducted a cohort study of consecutive patients, suspected of SARS-CoV-2 infection presented to the emergency department. We investigated haemostatic differences between SARS-CoV-2 PCR positive and negative patients, with dedicated coagulation analysis. The 519 included patients had a median age of 66 years, and 52.5% of the patients were male. Twenty-six percent of the patients were PCR-positive for SARS-CoV-2.PCR positive patients had increased levels of fibrinogen and (active) von Willebrand Factor (VWF) and decreased levels of protein C and α2-macroglobulin compared to the PCR negative patients. In addition, we found acquired activated protein C resistance in PCR positive patients. Furthermore, we found that elevated levels of factor VIII and VWF and decreased levels of ADAMTS-13 were associated with an increased incidence of thrombosis in PCR positive patients. In conclusion, we found that PCR positive patients had a pronounced prothrombotic phenotype, mainly due to an increase of endothelial activation upon admission to the hospital. These findings show that coagulation tests may be considered useful to discriminate severe cases of COVID-19 at risk for thrombosis.
- 28 April 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (4) , e0267605
Open AccessHaemostatic differences between SARS-CoV-2 PCR-positive and negative patients at the time of hospital admission
Coronavirus disease 2019 (COVID-19), caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is associated with thrombosis. We conducted a cohort study of consecutive patients, suspected of SARS-CoV-2 infection presented to the emergency department. We investigated haemostatic differences between SARS-CoV-2 PCR positive and negative patients, with dedicated coagulation analysis. The 519 included patients had a median age of 66 years, and 52.5% of the patients were male. Twenty-six percent of the patients were PCR-positive for SARS-CoV-2.PCR positive patients had increased levels of fibrinogen and (active) von Willebrand Factor (VWF) and decreased levels of protein C and α2-macroglobulin compared to the PCR negative patients. In addition, we found acquired activated protein C resistance in PCR positive patients. Furthermore, we found that elevated levels of factor VIII and VWF and decreased levels of ADAMTS-13 were associated with an increased incidence of thrombosis in PCR positive patients. In conclusion, we found that PCR positive patients had a pronounced prothrombotic phenotype, mainly due to an increase of endothelial activation upon admission to the hospital. These findings show that coagulation tests may be considered useful to discriminate severe cases of COVID-19 at risk for thrombosis.
- Open Access
- 7 January 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (1) , e0260897
Association of genetic variations in ACE2, TIRAP and factor X with outcomes in COVID-19
Background: Coronavirus disease 2019 (COVID-19), caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), can manifest with varying disease severity and mortality. Genetic predisposition influences the clinical course of infectious diseases. We investigated whether genetic polymorphisms in candidate genes ACE2, TIRAP, and factor X are associated with clinical outcomes in COVID-19. Methods: We conducted a single-centre retrospective cohort study. All patients who visited the emergency department with SARS-CoV-2 infection proven by polymerase chain reaction were included. Single nucleotide polymorphisms in ACE2 (rs2285666), TIRAP (rs8177374) and factor X (rs3211783) were assessed. The outcomes were mortality, respiratory failure and venous thromboembolism. Respiratory failure was defined as the necessity of >5 litres/minute oxygen, high flow nasal oxygen suppletion or mechanical ventilation. Results: Between March and April 2020, 116 patients (35% female, median age 65 [inter quartile range 55–75] years) were included and treated according to the then applicable guidelines. Sixteen patients (14%) died, 44 patients (38%) had respiratory failure of whom 23 required endotracheal intubation for mechanical ventilation, and 20 patients (17%) developed venous thromboembolism. The percentage of TIRAP polymorphism carriers in the survivor group was 28% as compared to 0% in the non-survivor group (p = 0.01, Bonferroni corrected p = 0.02). Genotype distribution of ACE2 and factor X did not differ between survivors and non-survivors. Conclusion: This study shows that carriage of TIRAP polymorphism rs8177374 could be associated with a significantly lower mortality in COVID-19. This TIRAP polymorphism may be an important predictor in the outcome of COVID-19.
- 7 January 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (1) , e0260897
Open AccessAssociation of genetic variations in ACE2, TIRAP and factor X with outcomes in COVID-19
Background: Coronavirus disease 2019 (COVID-19), caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), can manifest with varying disease severity and mortality. Genetic predisposition influences the clinical course of infectious diseases. We investigated whether genetic polymorphisms in candidate genes ACE2, TIRAP, and factor X are associated with clinical outcomes in COVID-19. Methods: We conducted a single-centre retrospective cohort study. All patients who visited the emergency department with SARS-CoV-2 infection proven by polymerase chain reaction were included. Single nucleotide polymorphisms in ACE2 (rs2285666), TIRAP (rs8177374) and factor X (rs3211783) were assessed. The outcomes were mortality, respiratory failure and venous thromboembolism. Respiratory failure was defined as the necessity of >5 litres/minute oxygen, high flow nasal oxygen suppletion or mechanical ventilation. Results: Between March and April 2020, 116 patients (35% female, median age 65 [inter quartile range 55–75] years) were included and treated according to the then applicable guidelines. Sixteen patients (14%) died, 44 patients (38%) had respiratory failure of whom 23 required endotracheal intubation for mechanical ventilation, and 20 patients (17%) developed venous thromboembolism. The percentage of TIRAP polymorphism carriers in the survivor group was 28% as compared to 0% in the non-survivor group (p = 0.01, Bonferroni corrected p = 0.02). Genotype distribution of ACE2 and factor X did not differ between survivors and non-survivors. Conclusion: This study shows that carriage of TIRAP polymorphism rs8177374 could be associated with a significantly lower mortality in COVID-19. This TIRAP polymorphism may be an important predictor in the outcome of COVID-19.
- 11 December 2021
- Published by Oxford University Press (OUP) in Medical Mycology
- Vol. 60 (1)
Comparison of the PneumoGenius® and RealStar® Pneumocystis jirovecii PCR CE-IVD assays with a lab developed test for the detection of Pneumocystis jirovecii
Pneumocystis jirovecii (Pj) is a fungal pathogen that can cause severe and potential fatal pneumonia (Pneumocystis pneumonia, PCP) in immunocompromised patients. Microbiological diagnosis is necessary to confirm PCP, for which mainly real-time PCR assays are used by detecting Pj from bronchoalveolar lavage (BAL) specimens. In this study, we evaluate the performance of the CE-IVD PneumoGenius® assay and CE-IVD RealStar® Pneumocystis jirovecii PCR assay in comparison to the lab developed test (LDT) that is used in routine diagnostics. Comparison was done by including 100 BAL specimens: 25 retrospective specimens, selected based on results obtained with LDT (15 positive/10 negative), and 75 prospectively collected specimens. LDT (targeting MSG) was performed according to local procedures and the PneumoGenius® (targeting mtLSU and DHPS fas) and RealStar® assays (targeting mtLSU) according to the manufacturer's instructions. Combining results of retrospective and prospective analysis, sensitivity was 69.7, 100 and 100% for the LDT, PneumoGenius® and RealStar®, respectively. Specificity was 100% for LDT and Pneumogenius®, whereas RealStar® showed a specificity of 97%. Correlation of fungal loads found with the PneumoGenius® and RealStar® assays was high (R2: 0.98). The PneumoGenius® and RealStar® assays performed comparable, and both showed high sensitivity in comparison to the LDT. For optimal diagnosis of PCP, the LDT has to be replaced by another, more sensitive assay. In this study, we evaluated the performance of two commercially available CE-IVD cleared real-time PCR assays to detect Pneumocystis jirovecii in comparison to the lab-developed test as used in routine diagnostics. Performance of the CE-IVD real-time PCR assay was superior to the lab-developed test.
- 11 December 2021
- Published by Oxford University Press (OUP) in Medical Mycology
- Vol. 60 (1)
Comparison of the PneumoGenius® and RealStar® Pneumocystis jirovecii PCR CE-IVD assays with a lab developed test for the detection of Pneumocystis jirovecii
Pneumocystis jirovecii (Pj) is a fungal pathogen that can cause severe and potential fatal pneumonia (Pneumocystis pneumonia, PCP) in immunocompromised patients. Microbiological diagnosis is necessary to confirm PCP, for which mainly real-time PCR assays are used by detecting Pj from bronchoalveolar lavage (BAL) specimens. In this study, we evaluate the performance of the CE-IVD PneumoGenius® assay and CE-IVD RealStar® Pneumocystis jirovecii PCR assay in comparison to the lab developed test (LDT) that is used in routine diagnostics. Comparison was done by including 100 BAL specimens: 25 retrospective specimens, selected based on results obtained with LDT (15 positive/10 negative), and 75 prospectively collected specimens. LDT (targeting MSG) was performed according to local procedures and the PneumoGenius® (targeting mtLSU and DHPS fas) and RealStar® assays (targeting mtLSU) according to the manufacturer's instructions. Combining results of retrospective and prospective analysis, sensitivity was 69.7, 100 and 100% for the LDT, PneumoGenius® and RealStar®, respectively. Specificity was 100% for LDT and Pneumogenius®, whereas RealStar® showed a specificity of 97%. Correlation of fungal loads found with the PneumoGenius® and RealStar® assays was high (R2: 0.98). The PneumoGenius® and RealStar® assays performed comparable, and both showed high sensitivity in comparison to the LDT. For optimal diagnosis of PCP, the LDT has to be replaced by another, more sensitive assay. In this study, we evaluated the performance of two commercially available CE-IVD cleared real-time PCR assays to detect Pneumocystis jirovecii in comparison to the lab-developed test as used in routine diagnostics. Performance of the CE-IVD real-time PCR assay was superior to the lab-developed test.