Method to reduce undesired multiple fundus scattering effects in double-pass systems
- 29 April 2019
- journal article
- research article
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 36 (5) , 918-924
Abstract
Double-pass systems rely on backscattering of light by the human ocular fundus to assess the optical quality of the eye. In this work, we present a method to reduce double-pass image degradation caused by undesired multiple scattering effects in the eye fundus. The reduction is based on combined data processing of simultaneous measurements using two different configurations: one symmetric with equal entrance and exit pupils and another asymmetric with unequal entrance and exit pupils. Under certain conditions, such scattering effects may be effectively suppressed. Measurements of human eyes show that, although multiple fundus scattering imposes a shift on the estimations, double-pass systems can be used to predict the optical quality of the eye within a population.Keywords
Funding Information
- Horizon 2020 Framework Programme (H2020) (712949)
- Agència per a la Competitivitat de l’Empresa (ACCIÓ)
This publication has 22 references indexed in Scilit:
- Spherical refractive correction with an electro-optical liquid lens in a double-pass systemJournal of the European Optical Society-Rapid Publications, 2013
- Intra‐ and Intersession Repeatability of a Double‐Pass InstrumentOptometry and Vision Science, 2010
- The Pathways of Light Measured in Fundus ReflectometryVision Research, 1996
- Double-pass measurements of the retinal-image quality with unequal entrance and exit pupil sizes and the reversibility of the eye’s optical systemJournal of the Optical Society of America A, 1995
- Odd aberrations and double-pass measurements of retinal image qualityJournal of the Optical Society of America A, 1995
- Double-pass and interferometric measures of the optical quality of the eyeJournal of the Optical Society of America A, 1994
- Point-spread function for light scattered in the human ocular fundusJournal of the Optical Society of America A, 1994
- Monochromatic modulation transfer function of the human eye for different pupil diameters: an analytical expressionJournal of the Optical Society of America A, 1994
- Spectral reflectance of the human ocular fundusApplied Optics, 1989
- Determination of the point-spread function of human eyes using a hybrid optical–digital methodJournal of the Optical Society of America A, 1987