JMJuan A. Martínez-Roda

Juan A. Martínez-Roda

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Juan A. Martínez-Roda has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Quantification of forward scattering based on the analysis of double‐pass images in the frequency domain

    by Joan A. Martínez‐Roda, Carlos E. García‐Guerra, Fernando Diaz‐Doutón, Jaume Pujol, Antoni Salvador, Meritxell Vilaseca

    Purpose To assess forward intraocular scattering by means of a new parameter (Frequency Scatter Index, FSI3) based on the analysing double‐pass retinal images in the frequency domain, which minimizes the impact of aberrations on the results. Methods A prospective observational study was carried out in the Department of Ophthalmology, Hospital Universitari Mútua de Terrassa (Spain) on a group of 19 patients diagnosed with nuclear cataracts of various LOCSIII grades and a control group (CG) with nine healthy eyes. We recorded double‐pass retinal images with a custom set‐up based on a high‐sensitivity digital camera. The FSI3 was then computed using spatial frequencies below three cycles per degree. A preliminary validation of the FSI3 was performed on an artificial eye and two eyes of volunteers with and without commercial diffusers, and under defocus. Results The FSI3 was hardly affected by defocus values up to 2.50 D. The mean (and standard deviation) FSI3 values were as follows: for the CG, 1.19 (0.21); and for LOCSIII grades nuclear opacity 1, 2 and 3, 1.30 (0.12), 1.62 (0.21) and 1.85 (0.21), respectively. Eyes with cataracts showed FSI3 values significantly different than healthy eyes (p = 0.001). A good correlation (ρ = 0.861, p < 0.001) was found between the FSI3 and objective scatter index provided by a commercial instrument. Conclusion Since aberrations have little impact on the FSI3, the light scatter assessment becomes less dependent on the patient's refractive error compensation and the presence of higher‐order aberrations. The FSI3 can further the clinical and scientific understanding of forward intraocular scattering.


  • Method to reduce undesired multiple fundus scattering effects in double-pass systems

    by Carlos E. García-Guerra, Joan A. Martínez-Roda, Mikel Aldaba, Fernando Díaz-Doutón, Meritxell Vilaseca, Brian Vohnsen, Jaume Pujol

    Double-pass systems rely on backscattering of light by the human ocular fundus to assess the optical quality of the eye. In this work, we present a method to reduce double-pass image degradation caused by undesired multiple scattering effects in the eye fundus. The reduction is based on combined data processing of simultaneous measurements using two different configurations: one symmetric with equal entrance and exit pupils and another asymmetric with unequal entrance and exit pupils. Under certain conditions, such scattering effects may be effectively suppressed. Measurements of human eyes show that, although multiple fundus scattering imposes a shift on the estimations, double-pass systems can be used to predict the optical quality of the eye within a population.


  • Open Access

    System based on the contrast of Purkinje images to measure corneal and lens scattering

    by Pau Santos, Juan A. Martínez-Roda, Juan C. Ondategui, Fernando Díaz-Doutón, Jorge A. Ortiz Cazal, Meritxell Vilaseca

    Current methods to measure intraocular scattering provide information on the total scattered light, which consists of the combined contributions originating from different ocular structures. In this work, we propose a technique for the objective and independent assessment of scattering caused by the cornea and the lens based on the analysis of the contrast of the third and fourth Purkinje images. The technique is preliminarily validated first by using artificial eyes with different levels of corneal and lens scattering; second, it is validated in eyes wearing customized contact lenses to simulate corneal scattering and eyes with nuclear cataracts. Finally, it is tested on a larger population of eyes with cataracts and corneal disorders to prove its clinical usefulness.


  • Open Access

    Comparison of the Adaptive Optics Vision Analyzer and the KR‐1 W for measuring ocular wave aberrations

    by Carles Otero, Meritxell Vilaseca, Montserrat Arjona, Joan A Martínez‐Roda, Jaume Pujol

    The aim was to assess the agreement in the measurement of ocular aberrations between a new Adaptive Optics Vision Analyzer (AOVA, Voptica, Murcia, Spain) and a commercial aberrometer (KR‐1 W, Topco...


  • Open Access

    Effects of aging on optical quality and visual function

    by Joan A Martínez‐Roda, Meritxell Vilaseca, Juan C Ondategui, Montserrat Aguirre, Jaume Pujol

    We assessed the effects of aging on visual function and optical quality in a healthy adult population and provide reference values for different age ranges.We conducted a prospective study with 198...


  • Open Access

    Response for light scattered in the ocular fundus from double-pass and Hartmann–Shack estimations

    by Carlos E. García-Guerra, Mikel Aldaba, Montserrat Arjona, Fernando Díaz-Doutón, Joan A. Martínez-Roda, Jaume Pujol

    Double-pass (DP) and Hartmann–Shack (HS) are complementary techniques based on reflections of light in the ocular fundus that may be used to estimate the optical properties of the human eye. Under conventional data processing, both of these assessment modes provide information on aberrations. In addition, DP data contain the effects of scattering. In the ocular fundus, this phenomenon may arise from the interaction of light with not only the retina, but also deeper layers up to which certain wavelengths may penetrate. In this work, we estimate the response of the ocular fundus to incident light by fitting the deviations between DP and HS estimations using an exponential model. In measurements with negligible intraocular scattering, such differences may be related to the lateral spreading of light that occurs in the ocular fundus due to the diffusive properties of the media at the working wavelength. The proposed model was applied in young healthy eyes to evaluate the performance of scattering in such a population. Besides giving a parameter with information on the ocular fundus, the model contributes to the understanding of the differences between DP and HS estimations.


  • Open Access

    Double-pass technique and compensation-comparison method in eyes with cataract

    by Juan A. Martínez-Roda, Meritxell Vilaseca, Juan C. Ondategui, Lorena Almudí, Moafak Asaad, Lorena Mateos-Pena, Montserrat Arjona, Jaume Pujol

    To clinically assess the objective scatter index (OSI) obtained from double-pass images and the log(s) parameter measured with the direct compensation-comparison psychophysical technique in eyes with cataract. Ophthalmology Service, Terrassa Hospital, Barcelona, Spain. Prospective observational case series. The analysis comprised eyes diagnosed with nuclear, cortical, or posterior subcapsular cataracts and healthy eyes (control group). Patient examinations included assessment of the manifest subjective refraction, corrected distance visual acuity, contrast sensitivity, and cataract grade using the Lens Opacities Classification System III (LOCS III) score. The protocol also included the straylight (log[s]) measured by the C-Quant device, measurement of the objective optical quality (Strehl ratio and modulation transfer function cutoff frequency), and the OSI (HD Analyzer). Significant correlations with LOCS III classification were found in terms of log(s) and OSI, although they were slightly stronger with OSI for all cataract types, which could be attributable to higher-order aberrations. The OSI and log(s) shared approximately 44% of the scattering estimation and to coincide on the visual function decline with scattering for the 3 cataract types evaluated. Limits to discriminate between healthy and cataractous eyes and sensitivity and specificity values were 1.15 (sensitivity 91%, specificity 100%) for log(s) and 1.18 (sensitivity 89%, specificity 100%) for OSI (P < .05). Both instruments provide complementary information to diagnose cataracts and follow patients. Although backscattered light from deeper retinal layers can have an effect on OSI, the double-pass image provides information to grade different types of cataract when assessing cataractous eyes for treatment. None of the authors has a financial or proprietary interest in any material or method mentioned.


  • Repeatability of Aberrometric Measurements With a New Instrument for Vision Analysis Based on Adaptive Optics

    by Carles Otero, Meritxell Vilaseca, Montserrat Arjona, Juan A. Martínez-Roda, Jaume Pujol

    PURPOSE: To evaluate intersession and intrasession repeatability of aberration data obtained with a new visual simulator based on adaptive optics, which includes a Hartmann-Shack aberrometer (Adaptive Optics Vision Analyzer; Voptica S.L., Murcia, Spain). METHODS: Thirty-one healthy right eyes were included in the study. To evaluate intrasession repeatability, three consecutive measurements without repositioning the patient or realigning the eye were obtained. Intersession repeatability was evaluated in three sessions. Aberrometric data computed from the second to the fifth order for a 4-mm pupil were used. Statistical analysis included the repeated measures analysis of variance (or the Wilcoxon signed rank test), the coefficient of repeatability, the Bland–Altman method, and the intraclass correlation coefficient. RESULTS: No significant differences in the intrasession and intersession repeatability analysis for any of the parameters ( P > .05) were found, suggesting a consistent variability of the instrument over time. Similar coefficient of repeatability values were obtained in the three sessions. The Bland–Altman analysis confirmed differences close to zero and the variations were independent of the mean within and between sessions. The intersession intraclass correlation coefficient values were generally above 0.75, suggesting moderate to high repeatability. However, some exceptions were found in the intrasession analysis. CONCLUSIONS: The findings suggest that the new instrument provides consistent and repeatable aberrometric data. It is therefore a suitable tool to perform consistent and repeatable visual simulations. [ J Refract Surg. 2015;31(3):188–194.]


  • Open Access

    Optical quality and intraocular scattering in a healthy young population

    by Joan A Martínez‐Roda, Meritxell Vilaseca, Juan C Ondategui, Anna Giner, Francisco J Burgos, Genís Cardona, Jaume Pujol

    Background: We objectively assessed the optical quality and intraocular scattering by means of parameters provided by a clinical double‐pass system in healthy young subjects and thereby we obtained new reference data for clinical diagnosis. We calculated normal values of neural contrast sensitivity function (nCSF) from the measured modulation transfer function (MTF) and the contrast sensitivity function (CSF). Methods: Eligible subjects were healthy adults aged from 18 to 30 years with a logMAR visual acuity (VA) of 0.0 or better and normal values of CSF. Optical quality measurements for a 4.0 mm pupil were performed using the Optical Quality Analysis System (OQAS) based on the double‐pass technique. The following parameters were analysed: the modulation transfer function cutoff frequency (MTFcutoff), the Strehl2D ratio, the OQAS values (OV) at 100, 20 and nine per cent contrasts and the objective scatter index (OSI). Results: A total of 178 volunteers responded to the call, of whom 181 eyes were finally part of the study taking into account the criteria for inclusion. The values for the optical quality parameters were: 44.54 ± 7.14 cpd (MTFcutoff), 0.27 ± 0.06 (Strehl2D ratio), 1.48 ± 0.24 (OV100%), 1.58 ± 0.32 (OV20%), 1.64 ± 0.39 (OV9%), and 0.38 ± 0.19 (OSI). The nCSF calculated was 1.76 ± 0.21 (3 cpd), 2.13 ± 0.23 (6 cpd), 2.01 ± 0.28 (12 cpd) and 1.86 ± 0.33 (18 cpd). Conclusion: The normal values provided can be a useful tool for discriminating healthy eyes from early abnormal ones in which the optical quality or sensory function is impaired.