Abstract
This was a randomised controlled trial studying the safety of a new short metaphyseal fixation (SMF) stem. We hypothesised that it would have similar early clinical results and micromovement to those of a standard-length tapered Synergy metaphyseal fixation stem. Using radiostereometric analysis (RSA) we compared the two stems in 43 patients. A short metaphyseal fixation stem was used in 22 patients and a Synergy stem in 21 patients. No difference was found in the clinical outcomes pre- or post-operatively between groups. RSA showed no significant differences two years post-operatively in mean micromovement between the two stems (except for varus/valgus tilt at p = 0.05) (subsidence 0.94 mm (sd 1.71) vs 0.32 mm (sd 0.45), p = 0.66; rotation 0.96° (sd 1.49) vs 1.41° (sd 2.95), p = 0.88; and total migration 1.09 mm (sd 1.74) vs 0.73 mm (sd 0.72), p = 0.51). A few stems (four SMF and three Synergy) had initial migration > 1.0 mm but stabilised by three to six months, with the exception of one SMF stem which required revision three years post-operatively. For most stems, total micromovement was very low at two years (subsidence < 0.5 mm, rotation < 1.0°, total migration < 0.5 mm), which was consistent with osseous ingrowth. The small sample makes it difficult to confirm the universal applicability of or elucidate the potential contraindications to the use of this particular new design of stem.Keywords
This publication has 34 references indexed in Scilit:
- A prospective cohort study on the short collum femoris-preserving (CFP) stem using RSA and DXAActa Orthopaedica, 2013
- Migration analysis of a metaphyseal anchored short-stem hip prosthesisActa Orthopaedica, 2012
- 5-year clinical and radiostereometric analysis (RSA) follow-up of 39 CUT femoral neck total hip prostheses in young osteoarthritis patientsActa Orthopaedica, 2012
- Fixation of the fully hydroxyapatite-coated Corail stem implanted due to femoral neck fractureActa Orthopaedica, 2011
- Subsidence of a cementless femoral component influenced by body weight and body mass indexInternational Orthopaedics, 2011
- A prospective randomized study comparing electrochemically deposited hydroxyapatite and plasma-sprayed hydroxyapatite on titanium stemsActa Orthopaedica, 2010
- The migration patterns of two versions of the Furlong cementless femoral stemThe Journal of Bone and Joint Surgery. British volume, 2010
- Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA studyInternational Orthopaedics, 2009
- Survivorship of 2000 Tapered Titanium Porous Plasma-sprayed Femoral ComponentsClinical Orthopaedics and Related Research, 2009
- A 12-Item Short-Form Health SurveyMedical Care, 1996