Optical coherence tomography angiography (OCTA) is increasingly becoming a popular inspection tool for biomedical imaging applications. By exploring the amplitude, phase and complex information available in OCT signals, numerous algorithms have been proposed that contrast functional vessel networks within microcirculatory tissue beds. However, it is not clear which algorithm delivers optimal imaging performance. Here, we investigate systematically how amplitude and phase information have an impact on the OCTA imaging performance, to establish the relationship of amplitude and phase stability with OCT signal-to-noise ratio (SNR), time interval and particle dynamics. With either repeated A-scan or repeated B-scan imaging protocols, the amplitude noise increases with the increase of OCT SNR; however, the phase noise does the opposite, i.e. it increases with the decrease of OCT SNR. Coupled with experimental measurements, we utilize a simple Monte Carlo (MC) model to simulate the performance of amplitude-, phase- and complex-based algorithms for OCTA imaging, the results of which suggest that complex-based algorithms deliver the best performance when the phase noise is < ~40 mrad. We also conduct a series of in vivo vascular imaging in animal models and human retina to verify the findings from the MC model through assessing the OCTA performance metrics of vessel connectivity, image SNR and contrast–to–noise ratio. We show that for all the metrics assessed, the complex-based algorithm delivers better performance than either the amplitude- or phase–based algorithms for both the repeated A-scan and the B-scan imaging protocols, which agrees well with the conclusion drawn from the MC simulations.Keywords
Funding Information
- National Heart, Lung, and Blood Institute (R01HL093140)
- National Eye Institute (R01EY024158)
- Research to Prevent Blindness to Department of Ophthalmology
This publication has 43 references indexed in Scilit:
- Split-spectrum amplitude-decorrelation angiography with optical coherence tomographyOptics Express, 2012
- Quantifying Optical Microangiography Images Obtained from a Spectral Domain Optical Coherence Tomography SystemInternational Journal of Biomedical Imaging, 2012
- Total retinal blood flow measurement with ultrahigh speed swept source/Fourier domain OCTBiomedical Optics Express, 2011
- Using ultrahigh sensitive optical microangiography to achieve comprehensive depth resolved microvasculature mapping for human retinaJournal of Biomedical Optics, 2011
- Correlation mapping method for generating microcirculation morphology from optical coherence tomography (OCT) intensity imagesJournal of Biophotonics, 2010
- Cellular phone‐based photoplethysmographic imagingJournal of Biophotonics, 2010
- High-resolution wide-field imaging of retinal and choroidal blood perfusion with optical microangiographyJournal of Biomedical Optics, 2010
- Doppler variance imaging for three-dimensional retina and choroid angiographyJournal of Biomedical Optics, 2010
- Three-dimensional microscopy of the tumor microenvironment in vivo using optical frequency domain imagingNature Medicine, 2009
- Three dimensional optical angiographyOptics Express, 2007