Accuracy of equilibrium magnetization mapping in sliced two‐dimensional spoiled gradient‐recalled echo pulse sequence with variable flip angle
- 6 February 2013
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 38 (5) , 1245-1250
Abstract
Purpose To evaluate the accuracy of an equilibrium magnetization (M0) map obtained using a two‐dimensional (2D) spoiled gradient‐recalled echo (SPGR) pulse sequence with variable flip angle (VFA). Materials and Methods Single‐slice 2D SPGR images of 4% agar gel phantoms with different gadolinium‐diethylene triamine pentaacetic acid (Gd‐DTPA) concentrations (0–1 mM) were obtained with a VFA (2–30°). The 2D SPGR‐VFA data were acquired with different repetition times (TRs; 7.8–117.2 ms), Gaussian and sinc RF pulses, and different field strengths (4.7, 7, and 9.4 Tesla). M0 and T1 maps were calculated from the 2D SPGR‐VFA data. M0 and T1 values were compared with those calculated from free‐relaxed 2D gradient‐recalled echo (GRE) images and inversion recovery‐prepared 2D SPGR images. The M0 and T1 slice profiles were also investigated. Results Consistent M0 values were obtained, regardless of the different Gd concentrations, TRs, and pulse sequences. The M0 slice profiles calculated from the sliced SPGR‐VFA data quantitatively reproduced those calculated from the free‐relaxed sliced GRE. In contrast, the T1 values calculated from the 2D SPGR‐VFA data were underestimated at a high Gd concentration, short TR, and Gaussian RF pulse. Conclusion M0 values calculated from 2D SPGR‐VFA images are highly quantitative. J. Magn. Reson. Imaging 2013;38:1245–1250.Keywords
This publication has 13 references indexed in Scilit:
- On the mechanisms enabling myocardial edema contrast in bSSFP‐based imaging approachesMagnetic Resonance in Medicine, 2011
- Increase in tumour permeability following TGF-β type I receptor-inhibitor treatment observed by dynamic contrast-enhanced MRIBritish Journal of Cancer, 2009
- Rapid high‐resolution T1 mapping by variable flip angles: Accurate and precise measurements in the presence of radiofrequency field inhomogeneityMagnetic Resonance in Medicine, 2006
- Accurate multislice gradient echo T1 measurement in the presence of non‐ideal RF pulse shape and RF field nonuniformityMagnetic Resonance in Medicine, 2001
- Improved 3D quantitative mapping of blood volume and endothelial permeability in brain tumorsJournal of Magnetic Resonance Imaging, 2000
- Absolute measurements of water content using magnetic resonance imaging: Preliminary findings in an in vivo focal ischemic rat modelMagnetic Resonance in Medicine, 2000
- Accuracy of T1 measurement in dynamic contrast-enhanced breast MRI using two- and three-dimensional variable flip angle fast low-angle shotJournal of Magnetic Resonance Imaging, 1999
- Quantitative regional brain water measurement with magnetic resonance imaging in a focal ischemia modelMagnetic Resonance in Medicine, 1997
- Probing tumor microvascularity by measurement, analysis and display of contrast agent uptake kineticsJournal of Magnetic Resonance Imaging, 1997
- Variations in slice shape and absorption as artifacts in the determination of tissue parameters in NMR imagingMagnetic Resonance in Medicine, 1985