Evaluation of Keratometry With a Novel Color-LED Corneal Topographer
Authors:
- Stijn KlijnSKStijn Klijn
- Nicolaas J. ReusNRNicolaas J. Reus
- Victor Arni D. P. SicamVSVictor Arni D. P. Sicam
Open Access
- 1 April 2015
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 31 (4) , 249-256
Abstract
PURPOSE: To assess the performance of a novel keratometer based on reflections of colored light-emitting diodes (LEDs) and compare it with devices based on Placido rings, monochromatic LEDs, and Scheimpflug images. METHODS: Sixty-three eyes of 63 patients with virgin corneas underwent keratometry with color-LED corneal topography (Cassini; i-Optics, The Hague, The Netherlands) and with devices based on Placido ring reflections (Keratron; Optikon, Rome, Italy), monochromatic LED reflections (Lenstar; Haag-Streit, Koeniz, Switzerland), and Scheimpflug imaging (Pentacam; Oculus Optikgeräte, Wetzlar, Germany). Three repeated measurements were performed with each device. Comparability and repeatability of corneal power and cylinder measurements were assessed. The Bonferroni-corrected α-threshold for statistical significance was 0.016. RESULTS: Corneal power measurements with the Cassini topographer were not statistically significantly different from those with the Pentacam ( P = .64). They were statistically significantly lower than those with the Keratron and Lenstar ( P < .01), but the differences were of negligible clinical relevance. Cylinder measurements with the Cassini topographer were not statistically significantly different from those with any other device ( P = .46). Repeatability of Cassini corneal power measurements was not statistically significantly different from that of the Keratron ( P = .02), but was statistically significantly lower than that of the Lenstar and Pentacam ( P < .001). Repeatability of Cassini cylinder measurements was statistically significantly higher than that of the Pentacam and Keratron ( P < .001), but was not statistically significantly different from that of the Lenstar ( P > .05). CONCLUSIONS: Corneal power and cylinder measurements with color-LED corneal topography yielded values that were comparable to those of other commonly used devices. Repeatability of corneal power measurements was lower compared to some devices, but repeatability of cylinder measurements was relatively high. This may be of particular interest when using toric intraocular lenses. [ J Refract Surg. 2015;31(4):249–256.]Keywords
This publication has 24 references indexed in Scilit:
- Forme Fruste Keratoconus Imaging and Validation via Novel Multi-Spot Reflection TopographyCase Reports in Ophthalmology, 2013
- Accuracy of toric intraocular lens implantation in cataract and refractive surgeryJournal of Cataract & Refractive Surgery, 2011
- Clinical Validation of Point‐Source Corneal Topography in KeratoplastyOptometry and Vision Science, 2011
- Accuracy of Scheimpflug corneal power measurements for intraocular lens power calculationJournal of Cataract & Refractive Surgery, 2009
- Performance in Specular Reflection and Slit‐Imaging Corneal TopographyOptometry and Vision Science, 2009
- Assessment and statistics of surgically induced astigmatismActa Ophthalmologica, 2008
- Sources of error in intraocular lens power calculationJournal of Cataract & Refractive Surgery, 2008
- Comparison of Different Techniques of Anterior Chamber Depth and Keratometric MeasurementsAmerican Journal of Ophthalmology, 2007
- Topographer Reconstruction of the Nonrotation–Symmetric Anterior Corneal Surface FeaturesOptometry and Vision Science, 2006
- Improved Method for Calculation of Corneal Topography for Any Photokeratoscope GeometryOptometry and Vision Science, 1991