Assessment of 4D flow MRI for quantification of left-to-right shunt in pediatric patients with ventricular septal defect: comparison with right heart catheterization
Open Access
- 22 July 2024
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 11, 1399110
Abstract
Objectives: The percentage of shunt fraction significantly impacts the management of patients with congenital shunts, influencing strategic choices such as surgical or interventional procedures. This study compared the estimated shunt fraction (the ratio of pulmonary-to-systemic flow, Qp/Qs) for quantifying the left-to-right shunt in children with ventricular septal defect (VSD) using heart catheterization, four-dimensional (4D) flow, and two-dimensional (2D) flow magnetic resonance imaging (MRI). The goal was to establish a non-invasive and reliable measurement ratio between pulmonary and systemic blood flow in these patients.Methods: Between July 2022 and June 2023, patients scheduled to undergo invasive right heart catheterization were included in this study. MRI was performed one hour before the catheterization procedure. The correlation of shunt fraction was assessed between all methods after calculating the Qp/Qs ratio from 2D and 4D flow MRI and catheterization.Results: A total of 24 patients (aged 3–15 years, eight females) were ultimately included in the study. The Qp/Qs ratios obtained from 4D flow had a robust correlation (correlation coefficient r = 0.962) compared to those obtained during catheterization. Cardiac catheterization recorded the mean shunt fraction at 1.499 ± 0.396, while 4D flow measured it at 1.403 ± 0.344, with no significant difference between the two techniques. Moreover, there was a reasonable correlation (r = 0.894) between 2D flow measurements of Qp/Qs and the results obtained from catheterization, with a mean shunt fraction of 1.326 ± 0.283.Conclusion: 4D flow MRI has the potential to be a non-invasive method for accurately measuring the left-to-right shunt in children with VSD.Keywords
This publication has 39 references indexed in Scilit:
- Comprehensive Neonatal Cardiac, Feed and Wrap, Non‐contrast, Non‐sedated, Free‐breathing Compressed Sensing 4D Flow MRI AssessmentJournal of Magnetic Resonance Imaging, 2022
- Comparison of 2D and 4D Flow MRI in Neonates Without General AnesthesiaJournal of Magnetic Resonance Imaging, 2022
- Recommendations for cardiovascular magnetic resonance and computed tomography in congenital heart disease: a consensus paper from the CMR/CCT working group of the Italian Society of Pediatric Cardiology (SICP) and the Italian College of Cardiac Radiology endorsed by the Italian Society of Medical and Interventional Radiology (SIRM) Part ILa radiologia medica, 2022
- 4D flow MRI applications in congenital heart diseaseEuropean Radiology, 2020
- Genetic Contribution to Congenital Heart Disease (CHD)Pediatric Cardiology, 2019
- Flow quantification dependency on background phase correction techniques in 4D‐flow MRIMagnetic Resonance in Medicine, 2019
- Congenital heart disease assessment with 4D flow MRIJournal of Magnetic Resonance Imaging, 2015
- 4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiographyPediatric Radiology, 2014
- 4D flow MRIJournal of Magnetic Resonance Imaging, 2012
- Complications of pediatric cardiac catheterization: A review in the current eraCatheterization and Cardiovascular Interventions, 2008