Suppression of artifacts in X-ray phase-contrast images retrieved by Fourier transform
- 1 January 2021
- journal article
- research article
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 70 (10) , 104101
Abstract
Over the last two decades, the grating-based phase-contrast imaging has aroused the interest of a number of researchers. It could provide an access to three complementary signals simultaneously: the conventional absorption contrast, the differential phase contrast related to refraction of incident wave, and the dark-field contrast that relates to ultra small angle scattering in a sample. The grating-based phase-contrast signals have higher contrast sensitivity for some types of soft samples than the absorption signals. Dark-field signals have better diagnostic effects in the detection of lung tumors, pneumothorax and the identification of microcalcifications in breast. There are two main phase retrieval methods in grating-based X-ray phase-contrast imaging, i.e. phase stepping method and Fourier transform method. The phase signals retrieved by phase stepping is high precise and has low noise. But the sample suffers high dose due to at least three exposures. The phase signals retrieved by Fourier transform is low-dose due to the fact that only one image with sample is needed, but it is easily affected by artifacts when the size of the filtering window is too large. However, when the size of the filtering window is too small, the high-frequency information of the phase-contrast image will be lost, and the image will become blurred. A trade-off between definitions of the image and artifacts should be made. Since the phase-contrast signal and the dark-field signal of the sample are modulated by carrier fringes, the frequency spectrum of the detected image consists of many different harmonics. The artifacts in the retrieved signals originate from the spectrum aliasing between primary peak around zero spatial frequency and first-order harmonic peaks. Therefore, the subtraction between two images with phase difference can remove the primary peak, and the artifacts in the phase-contrast signals and dark-field signals will be suppressed. In order to further suppress the artifacts, we increase the frequency of carrier fringes, which results in a larger distance between first-order harmonic peaks in frequency domain. We finally attain artifact-free phase-contrast images and dark-field images while maintaining high definition of the images. The method proposed here is not only applicable to incoherent imaging system, but also to Talbot-Lau interferometer, and it would be useful in fast and low-dose X-ray phase-contrast and dark-field imaging.Keywords
This publication has 20 references indexed in Scilit:
- X-ray phase radiography and tomography with grating interferometry and the reverse projection techniqueJournal of Physics D: Applied Physics, 2013
- In-vivo dark-field and phase-contrast x-ray imagingScientific Reports, 2013
- Grating-based darkfield imaging of human breast tissueZeitschrift für Medizinische Physik, 2013
- Low-dose, simple, and fast grating-based X-ray phase-contrast imagingProceedings of the National Academy of Sciences, 2010
- Fourier X-ray Scattering Radiography Yields Bone Structural InformationRadiology, 2009
- Hard-X-ray dark-field imaging using a grating interferometerNature Materials, 2008
- Phase Tomography by X-ray Talbot Interferometry for Biological ImagingJapanese Journal of Applied Physics, 2006
- Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sourcesNature Physics, 2006
- Demonstration of X-Ray Talbot InterferometryJapanese Journal of Applied Physics, 2003
- Improved Fourier transform profilometry for the automatic measurement of 3D object shapesOptical Engineering, 1990