JGJinchuan Guo

Jinchuan Guo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jinchuan Guo has a total of 53 co-authors. Here are the top co-authors by number of shared publications:

  • Jun Yang

    Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen, 518060, China

    3 shared publications
  • Dong Liang

    Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences

    2 shared publications
  • Liu Xin

    Shenzhen Univ, Coll Optoelect Engn, Minist Educ & Guangdong Prov, Key Lab Optoelect Devices & Syst, Shenzhen 518060, Guangdong, Peoples R China

    2 shared publications
  • Yao-Hu Lei

    Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen, 518060, China

    2 shared publications
  • Yi Ming-Hao

    Shenzhen Univ, Coll Optoelect Engn, Minist Educ & Guangdong Prov, Key Lab Optoelect Devices & Syst, Shenzhen 518060, Guangdong, Peoples R China

    2 shared publications
  • Yongshuai Ge

    Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences

    2 shared publications

Latest Publications

  • Open Access

    Research Progress of Grating-Based X-Ray Phase-Contrast Imaging and Key Devices

    by Fangke Zong, Jun Yang, Jinchuan Guo, Jingjin Zhang, Yang Du, Chenggong Zhang

    X-ray phase-contrast imaging presents a significant advancement in the field of X-ray imaging, surpassing traditional X-ray absorption imaging in detecting hydrogen substances. It effectively addresses the limitations of the latter in providing contrast for imaging weakly absorbing objects, thereby opening up vast potential applications in biomedical research, materials science, and industrial inspection. This article initially explores the fundamental principles of X-ray phase-contrast imaging and several prevalent imaging techniques. Notably, imaging devices such as grating-based Talbot–Lau interferometers emerge as the most promising in phase-contrast imaging due to their exceptional compatibility and imaging quality. Furthermore, this article introduces key parameters for assessing the quality of grating phase-contrast imaging, specifically image noise and sensitivity, along with their calculation methods. These insights are valuable for optimizing grating-based phase-contrast imaging devices. Lastly, this article examines potential applications and advancements in the key components of X-ray phase-contrast imaging while addressing current challenges and future directions in its technological development. This article aims to provide insights and inspiration for scholars interested in this field.


  • Super-resolution dual-layer CBCT imaging with model-guided deep learning

    by Jiongtao Zhu, Ting Su, Xin Zhang, Han Cui, Yuhang Tan, Hairong Zheng, Dong Liang, Jinchuan Guo, Yongshuai Ge

    Objective. This study aims at investigating a novel super resolution CBCT imaging approach with a dual-layer flat panel detector (DL-FPD). Approach. With DL-FPD, the low-energy and high-energy projections acquired from the top and bottom detector layers contain over-sampled spatial information, from which super-resolution CT images can be reconstructed. A simple mathematical model is proposed to explain the signal formation procedure in DL-FPD, and a dedicated recurrent neural network, named suRi-Net, is developed based upon the above imaging model to nonlinearly retrieve the high-resolution dual-energy information. Physical benchtop experiments are conducted to validate the performance of this newly developed super-resolution CBCT imaging method. Main Results. The results demonstrate that the proposed suRi-Net can accurately retrieve high spatial resolution information from the low-energy and high-energy projections of low spatial resolution. Quantitatively, the spatial resolution of the reconstructed CBCT images from the top and bottom detector layers is increased by about 45% and 54%, respectively. Significance. In the future, suRi-Net will provide a new approach to perform high spatial resolution dual-energy imaging in DL-FPD-based CBCT systems.


  • Open Access

    Highly Sensitive Temperature Sensor Based on Cascaded Polymer-Infiltrated Fiber Mach–Zehnder Interferometers Operating near the Dispersion Turning Point

    by Jia He, Fengchan Zhang, Xizhen Xu, Bin Du, Jiafeng Wu, Zhuoda Li, Zhiyong Bai, Jinchuan Guo, Yiping Wang, Jun He

    High-accuracy temperature measurement plays a vital role in biomedical, oceanographic, and photovoltaic industries. Here, a highly sensitive temperature sensor is proposed and demonstrated based on cascaded polymer-infiltrated Mach–Zehnder interferometers (MZIs), operating near the dispersion turning point. The MZI was constructed by splicing a half-pitch graded index fiber (GIF) and two sections of single-mode fiber and creating an inner air cavity based on femtosecond laser micromachining. The UV-curable polymer-infiltrated air cavity functioned as one of the interference arms of MZI, and the residual GIF core functioned as the other. Two MZIs with different cavity lengths and infiltrated with the UV-curable polymers, having the refractive indexes on the different sides of the turning point, were created. Moreover, the effects of the length and the bending way of transmission SMF between the first and the second MZI were studied. As a result, the cascaded MZI temperature sensor exhibits a greatly enhanced temperature sensitivity of −24.86 nm/°C based on wavelength differential detection. The aforementioned result makes it promising for high-accuracy temperature measurements in biomedical, oceanographic, and photovoltaic applications.


  • Analysis of period and visibility of dual phase grating interferometer

    by Jun Yang, Jian-Heng Huang, Yao-Hu Lei, Jing-Biao Zheng, Yu-Zheng Shan, Da-Yu Guo, Jin-Chuan Guo

    Dual phase grating interferometer may simultaneously achieve large field of view and high x-ray dose efficiency. Here, we develop a simple theoretical method to better understand the imaging process of the dual phase grating interferometer. The derivation process of fringe period and the optimal visibility conditions of the dual phase grating interferometer are given in detail. Then, we theoretically prove that the fringe period and optimal visibility conditions of the dual phase grating interferometer include that of the Talbot interferometer. By comparing our experimental results with those of other researchers, we find that when the positions of phase gratings are far away from the positions where the fringe visibility is optimal, the fringe period of the dual π-phase grating interferometer is twice the theoretical results under the illumination of polychromatic x-ray. This conclusion may explain the contradictory research results of dual phase grating interferometer among different researchers.


  • Ray tracing method for removing sidelobe laser interference in AOTF-based hyperspectral imaging

    by Shaoguang Shi, Xiaobo Lv, Ziye Wang, Jinchuan Guo, Yuanhao Huang

    The sidelobe phenomenon of acousto-optic tunable filter (AOTF)-based hyperspectral imaging is the result of the phase mismatching condition, which will reduce the quality of hyperspectral imaging data. This phenomenon can be observed in two specified scenes, namely, high brightness panchromatic target imaging and high brightness monochromatic target imaging. In this paper, the acousto-optic interaction in these two scenes is discussed using the phase matching condition. As a follow-up work of the previous related research, this paper studies laser interference in AOTF imaging, which is a typical example of the second case. A method to remove laser sidelobes in AOTF-based hyperspectral imaging is proposed, which combines a series of procedures including laser point extraction, reverse imaging before AOTF, ray tracing in AOTF, forward imaging process after AOTF, and laser elimination. Experimental results have verified the effectiveness of the proposed method.


  • Suppression of artifacts in X-ray phase-contrast images retrieved by Fourier transform

    by Jun Yang, Hao Wu, Kun-Hao Luo, Jin-Chuan Guo, Fang-Ke Zong

    Over the last two decades, the grating-based phase-contrast imaging has aroused the interest of a number of researchers. It could provide an access to three complementary signals simultaneously: the conventional absorption contrast, the differential phase contrast related to refraction of incident wave, and the dark-field contrast that relates to ultra small angle scattering in a sample. The grating-based phase-contrast signals have higher contrast sensitivity for some types of soft samples than the absorption signals. Dark-field signals have better diagnostic effects in the detection of lung tumors, pneumothorax and the identification of microcalcifications in breast. There are two main phase retrieval methods in grating-based X-ray phase-contrast imaging, i.e. phase stepping method and Fourier transform method. The phase signals retrieved by phase stepping is high precise and has low noise. But the sample suffers high dose due to at least three exposures. The phase signals retrieved by Fourier transform is low-dose due to the fact that only one image with sample is needed, but it is easily affected by artifacts when the size of the filtering window is too large. However, when the size of the filtering window is too small, the high-frequency information of the phase-contrast image will be lost, and the image will become blurred. A trade-off between definitions of the image and artifacts should be made. Since the phase-contrast signal and the dark-field signal of the sample are modulated by carrier fringes, the frequency spectrum of the detected image consists of many different harmonics. The artifacts in the retrieved signals originate from the spectrum aliasing between primary peak around zero spatial frequency and first-order harmonic peaks. Therefore, the subtraction between two images with phase difference can remove the primary peak, and the artifacts in the phase-contrast signals and dark-field signals will be suppressed. In order to further suppress the artifacts, we increase the frequency of carrier fringes, which results in a larger distance between first-order harmonic peaks in frequency domain. We finally attain artifact-free phase-contrast images and dark-field images while maintaining high definition of the images. The method proposed here is not only applicable to incoherent imaging system, but also to Talbot-Lau interferometer, and it would be useful in fast and low-dose X-ray phase-contrast and dark-field imaging.


  • Enhancing the X-Ray Differential Phase Contrast Image Quality With Deep Learning Technique

    by Yongshuai Ge, Peizhen Liu, Yifan Ni, Jianwei Chen, Jiecheng Yang, Ting Su, Huitao Zhang, Jinchuan Guo, Hairong Zheng, Zhi-Cheng Li, et al.

    Objective: The purpose of this work is to investigate the feasibility of using deep convolutional neural network (CNN) to improve the image quality of a grating-based X-ray differential phase contrast imaging (XPCI) system. Methods: In this work, a novel deep CNN based phase signal extraction and image noise suppression algorithm (named as XP-NET) is developed. The numerical phase phantom, the ex vivo biological specimen and the ACR breast phantom are evaluated via the numerical simulations and experimental studies, separately. Moreover, images are also evaluated under different low radiation levels to verify its dose reduction capability. Results: Compared with the conventional analytical method, the novel XP-NET algorithm is able to reduce the bias of large DPC signals and hence increasing the DPC signal accuracy by more than 15%. Additionally, the XP-NET is able to reduce DPC image noise by about 50% for low dose DPC imaging tasks. Conclusion: This proposed novel end-to-end supervised XP-NET has a great potential to improve the DPC signal accuracy, reduce image noise, and preserve object details. Significance: We demonstrate that the deep CNN technique provides a promising approach to improve the grating-based XPCI performance and its dose efficiency in future biomedical applications.


  • Shifting curves based on the detector integration effect for x-ray phase contrast imaging

    by Jun Yang, Jin-Chuan Guo, Yao-Hu Lei, Ming-Hao Yi, Li Chen

    In theory, we find that the actual function of the analyzer grating in the Talbot–Lau interferometer is segmenting the self-images of the phase grating and choosing integral areas, which make sure that each period of self-images in one detector pixel contributes the same signal to the detector. Furthermore, in the case of the lack of an analyzer grating, the shifting curves are still existent in theory as long as the number of fringes is non-integral in a detector pixel, which is a sufficient condition for creating shifting curve. The sufficient condition is available for not only the Talbot–Lau interferometer and the inverse geometry of Talbot–Lau interferometer, but also the x-ray phase contrast imaging system based on geometrical optics. In practical applications, we propose a method to improve the performances of the existing systems by employing the sufficient condition. This method can shorten the system length, is applicable to large period gratings, and can use the detectors with large pixels and large field of view. In addition, the experimental arrangement can be simplified due to the lack of an analyzer grating. In order to improve detection sensitivity and resolution, we also give an optimal fringe period. We believe that the theory and method proposed here is a step forward for x-ray phase contrast imaging.


  • Line focal X-ray source imaging

    by Liu Xin, Yi Ming-Hao, Guo Jin-Chuan

    High spatial coherent and bright X-ray beam is necessary condition for acquiring high quality radiography image. However, traditional X-ray tube can only provide high flux X-ray light or high spatial coherent light. In general, X-ray photons are generated by using energetic electrons with several tens or even hundreds keV to hit a target. Unfortunately, over 99% electron energy are converted into heat rather than the energy of X-ray photons. Thus, the heat dissipation of the target restricts the emission power and radiation flux. Increasing the emission area of X-ray can relieve the heat dissipation, but it would bring another serious problemlow spatial coherence that is in inverse proportion to emission area or focal spot. In order to solve the conflict between brightness and spatial coherence, an X-ray source with one-dimensional coherence is proposed in this work. The new X-ray source has a special focal spot where one side is small enough to ensure the spatial coherence and the perpendicular side is big enough to provide sufficient X-ray flux. In the direction of long side, the long size of focal spot will result in losing the image details. Consequently, an algorithm of superposition and rotation, in which many images with different rotation angles are added together, is proposed to retrieve the lost information. On the other hand, the spatial transfer function of superposition is analyzed in the frequency domain, and the result shows that the method of superposition can transfer more components of frequency than single image. Based on a traditional X-ray tube, a line focal spot source is designed and fabricated. Two series of experiments are performed for different destinations. After 17 images of a chip with different rotation angles and the line focal spot are collected, those images are rotated in the reverse direction and added together. The image of superposition clearly presents some details which are invisible in one of 17 images. At the same tube voltage and for the same object, some comparative experiments with micro-focus source, line focal spot source and normal focal spot source are presented. Compared with traditional X-ray tube, line focal spot source can provide high-resolution image. In the aspect of image visibility, the new source has definite advantages compared with micro-focus source, despite no improvement in imaging resolution. Finally, the reason for the difference in imaging resolution is discussed from the aspects of spatial coherence and light flux.