The lattice parameter of silicon: a secondary realisation of the metre
Authors:
- Andrew YacootAYAndrew Yacoot
- Harald BosseHBHarald Bosse
- Ron DixsonRDRon Dixson
- 8 October 2020
- journal article
- research article
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (12) , 121001
Abstract
The 2019 revision of the International System of Units (SI) linked the seven base units to fundamental constants; only a minor rewording was necessary for the metre whose definition was already linked to the speed of light. However, the largest change in the metre realisation since 1983 occurred with the adoption of the lattice parameter of silicon as a secondary realisation of the metre to support dimensional nanometrology. The traceability of the d 220 silicon lattice spacing has been established through combined optical and x-ray interferometry with a relative uncertainty of 1.67 × 10 − 8 and three routes to traceability via the silicon lattice spacing have been formally recognised in the Mise en Pratique for the metre. These are length measurement using x-ray interferometry (relying on the known value for the lattice spacing rather than using x-ray interferometry to measure the lattice spacing) counting atoms on linewidth structures using transmission electron microscopy and using monoatomic steps to calibrate scanning probe microscopes. This paper describes these routes and highlights the opportunities this new secondary realisation presents.Keywords
This publication has 57 references indexed in Scilit:
- The European nanometrology landscapeNanotechnology, 2011
- TEM Sample Preparation and FIB-Induced DamageMRS Bulletin, 2007
- Critical review of the current status of thickness measurements for ultrathin SiO 2 on Si Part V: Results of a CCQM pilot studySurface and Interface Analysis, 2004
- Thin Dielectric Film Thickness Determination by Advanced Transmission Electron MicroscopyMicroscopy and Microanalysis, 2003
- History and progress in the accurate determination of the Avogadro constantReports on Progress in Physics, 2001
- High-resolution transmission electron microscopy calibration of critical dimension (CD) reference materialsIEEE Transactions on Semiconductor Manufacturing, 2001
- The silicon lattice parameter - an invariant quantity of nature?Metrologia, 1998
- A transmission electron microscope (TEM) calibration standard sample for all magnification, camera constant, and image/diffraction pattern rotation calibrationsMicroscopy Research and Technique, 1995
- A determination of the Avogadro ConstantZeitschrift für Physik B Condensed Matter, 1992
- An $aring$ngstr$ouml$m rulerJournal of Physics D: Applied Physics, 1968