AYAndrew Yacoot

Andrew Yacoot

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andrew Yacoot has a total of 126 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Active calibration standards for correlative scanning probe microscopy: towards comprehensive SI traceability for multimodal quantitative imaging

    by Teodor Gotszalk, Andrew Yacoot, Bartosz Pruchnik, Andrzej Sierakowski, Magdalena Kucharska, Paweł Janus

    This perspective article describes the state of the art in the development of active micro/nanosystems based calibration standards for scanning probe microscopes (SPMs) used to provide multi-measurand traceability at the nanoscale. The emerging concept of active references, where the measurand is generated dynamically by a controlled external signal, is discussed as an alternative to conventional passive calibration artifacts. Potential advantages and performance of active samples for traceable, programmable, and multi-measurand calibration are highlighted, particularly in the context of correlative microscopy. The paper also outlines key fabrication strategies for these devices and identifies the main technological and metrological challenges that must be addressed for their widespread adoption. Finally, future directions are discussed, including the development of integrated correlative calibration platforms based on microelectromechanical systems and complementary metal-oxide-semiconductor active standards capable of supporting quantitative nanoscale measurements across multiple SPM modalities.

  • Reflecting on the role of National Metrology Institutes on the occasion of the 125th anniversary of the National Physical Laboratory

    by Richard Brown, Andrew Yacoot

    As the National Physical Laboratory (NPL), the UK’s National Metrology Institute, celebrates its 125th anniversary, this perspectives article reflects on NPL’s history and provides some insight into the role of National Metrology Institutes in contributing towards the maintenance of the global measurement system, the International System of Units, the SI. It also provides an outlook on the challenges facing National Metrology Institutes in meeting future requirements to support the SI and disseminate metrology to scientific and industrial communities where new challenges and opportunities are emerging. The article concludes by reaffirming that, even after 125 years, metrology and the global measurement system that it supports, remains essential in providing confidence in the accuracy and worldwide comparability of measurements needed for international trade, manufacturing and industry, human health and safety, protection of the environment, global climate studies and scientific research.


  • Open Access

    Large area high-speed atomic force microscopy with arbitrary scan path playback

    by Edward Heaps, Graham Bartlett, Jayesh Patel, Craig Goodman, Alison Raby, Andrew Yacoot, Petr Klapetek

    High-speed (up to 3 mm s−1) atomic force microscope imaging over large ranges (up to 100 μ m × 100 μ m ) is demonstrated using arbitrary non-raster scan paths. This scanning has been achieved by using a new approach to motion control with preprogrammed coordinates applied to a Queensgate XY-100D stage. This position-velocity-time type control gives smoother motion at high-speeds (HSs) compared to a real time control approach. Additionally a larger area of 0.5 mm × 0.7 mm is imaged by moving the HS stage on a coarse positioner and stitching data.


  • Open Access

    Roadmap on industrial imaging techniques

    by Jung-Ryul Lee, Hongki Yoo, Chia Chen Ciang, Young-Jin Kim, Daehee Kim, Teow Wee Teo, Zeinab Mahdavipour, Azizi Abdullah, Bee Ee Khoo, Mohd Zaid Abdullah, et al.

    Imaging plays a vital role in enabling the visualization and analysis of objects and phenomena across various scientific disciplines and industrial sectors, spanning a wide range of length and time scales. This roadmap presents a critical overview of 13 industrial imaging techniques, which are organized into three thematic categories according to their applicability to either solid, fluid, or both solid and fluid targets. The objectives of this roadmap are to highlight challenges and provide perspectives for next-generation imaging systems, which can serve as a guide to researchers and funding agencies in identifying new prospects. It has been found that the common challenges of imaging techniques have remained fundamentally unchanged over the years, including improving coverage, speed, resolution, accuracy, and robustness; however, there is an increasing reliance on data-driven or artificial intelligence (AI) approaches. Addressing these challenges necessitates easy access to high-performance computing resources. Notably, the trustworthiness and traceability of AI approaches should be enhanced through the sharing of benchmarking data, balancing with physics-based techniques, and the adoption of more explainable AI.


  • Open Access

    Application of active piezoresistive cantilevers in high-eigenmode surface imaging

    by Bartosz Pruchnik, Dominik Badura, Władysław Kopczyński, Dariusz Czułek, Ivo W Rangelow, Virpi Korpelainen, Andrzej Sierakowski, Andrew Yacoot, Teodor Gotszalk

    One of the most important limitations of the atomic force microscopy (AFM) is scanning speed, whose high values are required for contemporary high-resolution, long-range diagnostic applications. The measurement bandwidth of an AFM depends on several factors, but usually results from the time constant of the oscillating cantilever, which is correlated with its resonance frequency and quality factor. We propose a method to overcome this problem by performing the surface measurements when the cantilever is vibrating in higher eigenmodes. In this paper we demonstrate the application of active piezoresistive cantilevers operating in this mode. The active piezoresistive cantilever comprises a piezoresistive deflection sensor, a deflection actuator and a nanotip. It is a complete micro-electro-mechanical system, ensuring the highest reliability of cantilever vibration control and detection. Higher eigenmode operations are usually difficult to implement as they usually result in lower deflection and lower sensitivity of the probe vibration deflection. Here we present an experimental modification of the structure of an active piezoresistive cantilever using focused ion beam machining that mitigates both weaknesses. This has enabled the cantilever to scan the surface at a scanning rate of 10 lines s−1 with a maximum speed of 500 μm s−1 and a data acquisition rate of 10 kS s−1, when the probe is vibrating at 380 kHz in the second eigenmode. We also describe a traceable calibration routine (based on analysis of the response of the piezoresistive detector, the output of the HeNe interferometer and precise control of the deflection actuator), together with the cantilever modification process and the development of the measurement setup. We show measurement results of dedicated calibration samples and silicon carbide crystal lattice references.


  • Open Access

    Stitching accuracy in large area scanning probe microscopy

    by Petr Klapetek, David Nečas, Edward Heaps, Bruno Sauvet, Vojtěch Klapetek, Miroslav Valtr, Virpi Korpelainen, Andrew Yacoot

    Image stitching is a technique that can significantly enlarge the scan area of scanning probe microscope (SPM) images. It is also the most commonly used method to cover large areas in high-speed SPM. In this paper, we provide details on stitching algorithms developed specifically to mitigate the effects of SPM error sources, namely the presence of scanner non-flatness. Using both synthetic data and flat samples we analyse the potential uncertainty contributions related to stitching, showing that the drift and line mismatch are the dominant sources of uncertainty. We also present the ‘flatten base’ algorithm that can significantly improve the stitched data results, at the cost of losing the large area form information about the sample.


  • Three-dimensional drift correction of localised non-raster scanning on atomic force microscopy

    by Xizhi Sun, Edward Heaps, Andrew Yacoot, Qingping Yang, Petr Grolich, Petr Klapetek

    Non-raster scanning can increase the scanning frame rate and measurement speed of atomic force microscopes (AFMs). It is also possible to correct the 3D drift during the non-raster scanning. However, the algorithm for the drift correction depends upon the properties of each scan pattern. While localised non-raster scanning using a rosette scan may be faster than the frequently used Lissajous scanning patterns, the drift correction is more challenging because the scan has crossing points only in local neighbouring segments where there are short temporal and spatial separations of the crossing paths. This design note presents a novel solution that successfully overcomes this problem and extends a drift correction method previously developed for Lissajous scans to the 3D drift correction of localised non-raster scanning using a rosette scan trajectory. The drift in the X, Y and Z axes can be determined using the crossing points and locally repeated scans of the same features. The general procedure is presented together with experiments using rosette scans of a two-dimensional lateral calibration standard. Experimental results have demonstrated that the method can effectively correct both the drift in the three axes and sample tilt, leading to significantly improved images. The method requires only localised crossing points in the scan and does not need additional scans to determine the three-dimensional drift based on cross-correlation and least squares techniques, and it can be used with any AFMs capable of rosette scanning.


  • Open Access

    Validation of MAPS: a novel 6-degree-of-freedom position sensor for nanopositioning

    by Richard Aras, James Dallas, Edward Heaps, László Varga, Andrew Yacoot

    Anemos’ multi-dimensional absolute position sensors (MAPS) consists of a photolithographically defined reference scale, a camera, and computer image processing that decodes the relative position of a camera to the scale. A series of experiments tested the novel opto-electronic sensor against traceable National Physical Laboratory optical interferometers (OI) with motion provided by nanopositioning stages. Initially, MAPS to OI agreement was verified to be within 5 nm in the lateral (XY) axes across 100 μm travel. However, when MAPS, OI, and stage position were correlated across much finer steps, MAPS demonstrated repeatability and noise below 100 pm, indicating that the larger discrepancies seen previously were due to Abbe effects, servo-mechanical, and other OI/MAPS-extrinsic factors. In a third experiment, the outputs of four orthogonally placed MAPS 6-degree-of-freedom (6DoF) sensors were correlated against each other, OI, and feedback from a single-axis stage. Here, MAPS displayed sub-nanometre agreement with other sensors, and consistency across independent MAPS sensors. A fourth experiment collected millions of MAPS sample points during repetitive 1 nm circular motion. Spectral analysis of these large datasets, correlations between noise in multiple axes and repeatability indicate MAPS may resolve single digit picometre movements. These results corroborate simulations and supports the feasibly of million-to-one position interpolation from the MAPS 5 μm-grid reference scale. This equates to an unprecedented 40-bit dynamic range since MAPS can sustain measurement resolution over metres of travel. Overall, the experimental series highlight the challenges of nanoscale calibration and benefit of full 6DoF sensing in real-world nano-positioning systems.