Intervention in Patients with Critical Pulmonary Stenosis in the Ductal Stenting Era
Authors:
- 31 March 2016
- journal article
- research article
- Published by Springer Nature in Pediatric Cardiology
- Vol. 37 (6) , 1037-1045
Abstract
We aimed to assess early and midterm outcomes of balloon valvuloplasty (BVP) procedure in patients with critical pulmonary stenosis (CPS) and to describe the predictors of the need for additional pulmonary flow and reintervention in this subgroup of patients. From 2005 to 2014, 56 neonates were diagnosed with CPS and were included in this study. All echocardiographic, catheterization and angiographic data obtained prior to the initial BVP and at follow-up were reviewed. BVP was successful in 55 neonates (98 %). Twenty-one neonates needed pulmonary blood flow augmentation after BVP (38 %). Ductal stenting (DS) was performed in 20. The patients’ mean tricuspid valve (TV) annulus diameter was 10.4 ± 2 mm, and the Z score was −1.29 ± 1 (−3.7 to 0.78). The mean pulmonary valve (PV) annulus diameter was 6 ± 0.9 mm, and the Z score was −1.74 ± 1 (−4.34 to 0.05). A transcatheter or surgical reintervention was performed in 11 patients. A TV Z score < −1.93 SD predicted the need for pulmonary blood flow augmentation after a successful BVP, with a sensitivity of 63.2% and a specificity of 84.4%. A PV Z score < −1.69 SD predicted the need for pulmonary flow augmentation, with a sensitivity of 74 %. The presence of bipartite RV was found to be a significant predictor of the need for reintervention (odds ratio 9.6). Our study showed the excellent immediate outcomes of BPV and DS in a pure cohort of patients with CPS. Prophylactic DS in selected cases seems reasonable and safe.Keywords
This publication has 25 references indexed in Scilit:
- Stent Implantation of the Arterial Duct in Newborns with a Truly Duct‐Dependent Pulmonary Circulation: A Single‐Center Experience with Emphasis on Aspects of the Interventional TechniqueJournal of Interventional Cardiology, 2010
- Balloon dilation of pulmonary valve stenosis in infants less than 3 kg: A 20‐year experienceCatheterization and Cardiovascular Interventions, 2009
- Current options, and long-term results for interventional treatment of pulmonary valvar stenosisCardiology in the Young, 2006
- Critical Pulmonary StenosisJournal of Interventional Cardiology, 2001
- Treatment of critical pulmonary valve stenosis by balloon dilatation in the neonateAmerican Heart Journal, 1996
- Morphologic and hemodynamic consequences after percutaneous balloon valvotomy for neonatal pulmonary stenosis: Medium-term follow-upJACC, 1996
- Balloon valvuloplasty in the neonate with critical pulmonary stenosisJACC, 1996
- Balloon dilation of critical valvar pulmonary stenosis in the first month of lifeCatheterization and Cardiovascular Diagnosis, 1995
- Modified technique for balloon valvuloplasty of critical pulmonary stenosis in the newbornJACC, 1993
- Management of neonatal critical pulmonic stenosis in the balloon valvotomy eraThe Annals of Thoracic Surgery, 1990