Dosimetric Optimization and Commissioning of a High Field Inline MRI-Linac
Open Access
- 14 February 2020
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 10, 136
Abstract
Purpose: Unique characteristics of MRI-linac systems and mutual interactions between their components pose specific challenges for their commissioning and quality assurance. The Australian MRI-linac is a prototype system which explores the inline orientation, with radiation beam parallel to the main magnetic field. The aim of this work was to commission the radiation-related aspects of this system for its application in clinical treatments. Methods: Physical alignment of the radiation beam to the magnetic field was fine-tuned and magnetic shielding of the radiation head was designed to achieve optimal beam characteristics. These steps were guided by investigative measurements of the beam properties. Subsequently, machine performance was benchmarked against the requirements of the IEC60976/77 standards. Finally, the geometric and dosimetric data was acquired, following the AAPM Task Group 106 recommendations, to characterize the beam for modeling in the treatment planning system and with Monte Carlo simulations. The magnetic field effects on the dose deposition and on the detector response have been taken into account and issues specific to the inline design have been highlighted. Results: Alignment of the radiation beam axis and the imaging isocentre within 2 mm tolerance was obtained. The system was commissioned at two source-to-isocentre distances (SIDs): 2.4 and 1.8 m. Reproducibility and proportionality of the dose monitoring system met IEC criteria at the larger SID but slightly exceeded it at the shorter SID. Profile symmetry remained under 103% for the fields up to ~34 × 34 and 21 × 21 cm2 at the larger and shorter SID, respectively. No penumbra asymmetry, characteristic for transverse systems, was observed. The electron focusing effect, which results in high entrance doses on central axis, was quantified and methods to minimize it have been investigated. Conclusion: Methods were developed and employed to investigate and quantify the dosimetric properties of an inline MRI-Linac system. The Australian MRI-linac system has been fine-tuned in terms of beam properties and commissioned, constituting a key step toward the application of inline MRI-linacs for patient treatments.Keywords
This publication has 46 references indexed in Scilit:
- MRI commissioning of 1.5T MR-linac systems – a multi-institutional studyRadiotherapy and Oncology, 2019
- MRI-Linear Accelerator Radiotherapy SystemsClinical Oncology, 2018
- First patients treated with a 1.5 T MRI-Linac: clinical proof of concept of a high-precision, high-field MRI guided radiotherapy treatmentPhysics in Medicine & Biology, 2017
- Performance of a clinical gridded electron gun in magnetic fields: Implications for MRI‐linac therapyMedical Physics, 2016
- The Australian Magnetic Resonance Imaging–Linac ProgramSeminars in Radiation Oncology, 2014
- The ViewRay System: Magnetic Resonance–Guided and Controlled RadiotherapySeminars in Radiation Oncology, 2014
- Effect of longitudinal magnetic fields on a simulated in‐line 6 MV linacMedical Physics, 2010
- First MR images obtained during megavoltage photon irradiation from a prototype integrated linac‐MR systemMedical Physics, 2009
- MRI/linac integrationRadiotherapy and Oncology, 2008
- Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose deposition in a transverse magnetic fieldPhysics in Medicine & Biology, 2004