    Rapid distortion correction enables accurate magnetic resonance imaging-guided real-time adaptive radiotherapy

    by Paul Z. Y Liu, Shanshan Shan, David Waddington, Brendan Whelan, Bin Dong, Gary Liney, Paul Keall


  • Open Access

    Dosimetric Optimization and Commissioning of a High Field Inline MRI-Linac

    by Urszula Jelen, Bin Dong, Jarrad Begg, Natalia Roberts, Brendan Whelan, Paul Keall, Gary Liney

    Purpose: Unique characteristics of MRI-linac systems and mutual interactions between their components pose specific challenges for their commissioning and quality assurance. The Australian MRI-linac is a prototype system which explores the inline orientation, with radiation beam parallel to the main magnetic field. The aim of this work was to commission the radiation-related aspects of this system for its application in clinical treatments. Methods: Physical alignment of the radiation beam to the magnetic field was fine-tuned and magnetic shielding of the radiation head was designed to achieve optimal beam characteristics. These steps were guided by investigative measurements of the beam properties. Subsequently, machine performance was benchmarked against the requirements of the IEC60976/77 standards. Finally, the geometric and dosimetric data was acquired, following the AAPM Task Group 106 recommendations, to characterize the beam for modeling in the treatment planning system and with Monte Carlo simulations. The magnetic field effects on the dose deposition and on the detector response have been taken into account and issues specific to the inline design have been highlighted. Results: Alignment of the radiation beam axis and the imaging isocentre within 2 mm tolerance was obtained. The system was commissioned at two source-to-isocentre distances (SIDs): 2.4 and 1.8 m. Reproducibility and proportionality of the dose monitoring system met IEC criteria at the larger SID but slightly exceeded it at the shorter SID. Profile symmetry remained under 103% for the fields up to ~34 × 34 and 21 × 21 cm2 at the larger and shorter SID, respectively. No penumbra asymmetry, characteristic for transverse systems, was observed. The electron focusing effect, which results in high entrance doses on central axis, was quantified and methods to minimize it have been investigated. Conclusion: Methods were developed and employed to investigate and quantify the dosimetric properties of an inline MRI-Linac system. The Australian MRI-linac system has been fine-tuned in terms of beam properties and commissioned, constituting a key step toward the application of inline MRI-linacs for patient treatments.


  • Open Access

    Technical Note: The first live treatment on a 1.0 Tesla inline MRI‐linac

    by Gary P. Liney, Urszula Jelen, Hilary Byrne, Bin Dong, Tara L. Roberts, Zdenka Kuncic, Paul Keall

    Purpose This work describes the first live imaging and radiation delivery performed on a prototype 1.0 Tesla inline MRI‐Linac system in a rat brain tumour model, which was conducted on 29th January 2019. Methods A human scale 1.0 Tesla MRI‐Linac was adapted to be suitable for animal studies via a specially constructed open 6‐channel receiver radiofrequency (RF) coil. A Fischer rat injected with 9L glioma cells in the right hemisphere was imaged and irradiated at day 11 post surgery as part of a larger cohort survival study. The rat was anaesthetized and positioned at the iscocentre of the MRI‐Linac. Imaging was used to localize the brain and confirm the presence of a tumour following the administration of a gadolinium nanoparticle contrast agent. A single dose of 10 Gy was delivered using a 2.25 x 2.90 cm radiation field covering the whole brain and verified with radiosensitive film in situ. Real‐time imaging was used throughout the irradiation period to monitor the animal and target position. Results The signal‐to‐noise ratio (SNR) measured in the rat brain was 38. Post‐contrast imaging was able to demonstrate a tumour of 5 mm diameter in the upper right hemisphere of the brain approximately 45 minutes after administration of the nanoparticles. The radiation beam had no impact on SNR and images at the rate of 2 Hz were effective in monitoring both respiration and intrafractional motion. In vivo film dosimetry confirmed the intended dose delivery. The total procedure time was 35 minutes. Conclusions We have successfully used MRI guidance to localize and subsequently deliver a radiation field to the whole brain of a rat with a right hemispheric tumour. Real‐time imaging during beam‐on was of sufficient quality to monitor breathing and perform exception gating of the treatment. This represents the first live use of a high field inline MRI‐Linac.


  • Development of multi-purpose 3D printed phantoms for MRI

    by Robba Rai, Yu Feng Wang, David Manton, Bin Dong, Shrikant Deshpande, Gary P Liney

    This work describes the development and application of 3D printed MRI phantoms. Unlike traditional phantoms these test objects are made from solid materials which can be imaged directly without filling. The models were manufactured using both MRI visible and invisible materials. The MRI visible materials were imaged on a 3T system to quantify their T 1 and T 2 properties and CT to quantify the electron density. Three phantoms are described: a distortion phantom was imaged on an open bore MRI system to assess distortion over a 30 cm field-of-view; a solid tumour model was imaged using a motion simulator and compared to a standard water phantom to assess reduction in artefacts; finally, a test object created for textural analysis was evaluated on two 3T systems and reproducibility was assessed. Material 1 was the main material used in all phantom models and has a T 1 and T 2 of 152.3 ± 3.7 ms and 56.7 ± 2.5 ms and a CT density of 127.9 HU. Material 2 had a CT density of 115.1 HU and material 3 had a T 1 and T 2 of 149.5 ± 2.9 ms and 68.8 ± 7.8 ms and CT density of 15.3 HU. Image tests demonstrated the suitability and advantage of each phantom over more traditional versions: a high density set of control points enabled a comprehensive measurement of geometric accuracy; sufficient signal with a reduction in artefact was observed in the motion phantom, and the texture model provided reproducible measurements with an ICC > 0.9 for over 76% of texture features. Three different phantoms have been successfully manufactured and used to demonstrate the application of 3D printable materials for MRI phantoms.


  • Open Access

    Imaging performance of a dedicated radiation transparent RF coil on a 1.0 Tesla inline MRI-linac

    by Gary P Liney, Bin Dong, Ewald Weber, Robba Rai, Aurelien Destruel, Roberto Garcia-Alvarez, David Manton, Urszula Jelen, Kevin Zhang, Michael Barton, et al.

    This work describes the first imaging studies on a 1.0 Tesla inline MRI-Linac using a dedicated transmit/receive RF body coil that has been designed to be completely radio transparent and provide optimum imaging performance over a large patient opening. A series of experiments was performed on the MRI-Linac to investigate the performance and imaging characteristics of a new dedicated volumetric RF coil: (1) numerical electromagnetic simulations were used to measure transmit efficiency in two patient positions; (2) image quality metrics of signal-to-noise ratio (SNR), ghosting and uniformity were assessed in a large diameter phantom with no radiation beam; (3) radiation induced effects were investigated in both the raw data (k-space) and image sequences acquired with simultaneous irradiation; (4) radiation dose was measured with and without image acquisition; (5) RF heating was studied using an MR-compatible fluoroptic thermometer and; (6) the in vivo image quality and versatility of the coil was demonstrated in normal healthy subjects for both supine and standing positions. Daily phantom measurements demonstrated excellent imaging performance with stable SNR over a period of 3 months (42.6 ± 0.9). Simultaneous irradiation produced no statistical change in image quality ( p > 0.74) and no interference in raw data for a 20 × 20 cm radiation field. The coil was found to be efficient over large volumes and negligible RF heating was observed. Volunteer scans acquired in both supine and standing positions provided artefact free images with good anatomical visualisation. The first completely radio transparent RF coil for use on a 1.0 Tesla MRI-Linac has been described. There is no impact on either the imaging or dosimetry performance with a simultaneous radiation beam. The open design enables imaging and radiotherapy guidance in a variety of positons.