Fast direct Monte Carlo optimization using the inverse kernel approach
Authors:
- Ludwig BognerLBLudwig Bogner
- Marco AltMAMarco Alt
- Thomas DirscherlTDThomas Dirscherl
- Ingo MorgensternIMIngo Morgenstern
- Christof LatschaCLChristof Latscha
- Mark RickheyMRMark Rickhey
- 5 June 2009
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (13) , 4051-4067
Abstract
The loss of treatment plan quality after segmentation following fluence optimization is a problem in IMRT. In a previous publication we showed that re-optimization helps to re-establish part of the plan quality. Recently the so-called direct aperture optimization method has been introduced to successfully overcome that difficulty. The aim of the present paper is to present in detail the integration of the inverse kernel method into direct aperture optimization. It can be shown that this integration leads to a system with high performance with regard to time, while Monte Carlo precision is maintained. The integrated simulated annealing optimization algorithm allows easy adaptation to any multi-leaf collimator and it is open to any complex objective function. Investigations of simulated annealing control parameters are performed to improve the performance. The system denoted by direct Monte Carlo optimization (DMCO) is demonstrated on the Carpet phantom and a clinical prostate case as well. Results are compared to inverse kernel optimizations, showing a remarkable time reduction and simultaneously an improvement in plan quality for the Carpet phantom.Keywords
This publication has 26 references indexed in Scilit:
- Quasi-IMAT Study with Conventional Equipment to Show High Plan Quality with a Single Gantry ArcStrahlentherapie und Onkologie, 2009
- A technique for generating phase-space-based Monte Carlo beamlets in radiotherapy applicationsPhysics in Medicine & Biology, 2008
- Normal tissue dose-effect models in biological dose optimisationZeitschrift für Medizinische Physik, 2008
- Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planningMedical Physics, 2007
- Application of an inverse kernel concept to Monte Carlo based IMRTMedical Physics, 2006
- Direct aperture optimization for IMRT using Monte Carlo generated beamletsMedical Physics, 2006
- IMRT treatment planning—A comparative inter-system and inter-centre planning exercise of the ESTRO QUASIMODO groupRadiotherapy and Oncology, 2005
- A virtual photon energy fluence model for Monte Carlo dose calculationMedical Physics, 2003
- Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithmMedical Physics, 1999
- A generalized pencil beam algorithm for optimization of radiation therapyMedical Physics, 1994