Latest Publications

  • Fast direct Monte Carlo optimization using the inverse kernel approach

    by Ludwig Bogner, Marco Alt, Thomas Dirscherl, Ingo Morgenstern, Christof Latscha, Mark Rickhey

    The loss of treatment plan quality after segmentation following fluence optimization is a problem in IMRT. In a previous publication we showed that re-optimization helps to re-establish part of the plan quality. Recently the so-called direct aperture optimization method has been introduced to successfully overcome that difficulty. The aim of the present paper is to present in detail the integration of the inverse kernel method into direct aperture optimization. It can be shown that this integration leads to a system with high performance with regard to time, while Monte Carlo precision is maintained. The integrated simulated annealing optimization algorithm allows easy adaptation to any multi-leaf collimator and it is open to any complex objective function. Investigations of simulated annealing control parameters are performed to improve the performance. The system denoted by direct Monte Carlo optimization (DMCO) is demonstrated on the Carpet phantom and a clinical prostate case as well. Results are compared to inverse kernel optimizations, showing a remarkable time reduction and simultaneously an improvement in plan quality for the Carpet phantom.


  • Verification of head & neck IMRT-plans by Monte Carlo simulation

    by D. Schoenenberg, M. Rickhey, B. Dobler, T. Goetzfried, L. Bogner

  • Open Access

    Comparison of direct machine parameter optimization versus fluence optimization with sequential sequencing in IMRT of hypopharyngeal carcinoma

    by Barbara Dobler, Fabian Pohl, Ludwig Bogner, Oliver Koelbl

    Background: To evaluate the effects of direct machine parameter optimization in the treatment planning of intensity-modulated radiation therapy (IMRT) for hypopharyngeal cancer as compared to subsequent leaf sequencing in Oncentra Masterplan v1.5. Methods: For 10 hypopharyngeal cancer patients IMRT plans were generated in Oncentra Masterplan v1.5 (Nucletron BV, Veenendal, the Netherlands) for a Siemens Primus linear accelerator. For optimization the dose volume objectives (DVO) for the planning target volume (PTV) were set to 53 Gy minimum dose and 59 Gy maximum dose, in order to reach a dose of 56 Gy to the average of the PTV. For the parotids a median dose of 22 Gy was allowed and for the spinal cord a maximum dose of 35 Gy. The maximum DVO to the external contour of the patient was set to 59 Gy. The treatment plans were optimized with the direct machine parameter optimization ("Direct Step & Shoot", DSS, Raysearch Laboratories, Sweden) newly implemented in Masterplan v1.5 and the fluence modulation technique ("Intensity Modulation", IM) which was available in previous versions of Masterplan already. The two techniques were compared with regard to compliance to the DVO, plan quality, and number of monitor units (MU) required per fraction dose. Results: The plans optimized with the DSS technique met the DVO for the PTV significantly better than the plans optimized with IM (p = 0.007 for the min DVO and p < 0.0005 for the max DVO). No significant difference could be observed for compliance to the DVO for the organs at risk (OAR) (p > 0.05). Plan quality, target coverage and dose homogeneity inside the PTV were superior for the plans optimized with DSS for similar dose to the spinal cord and lower dose to the normal tissue. The mean dose to the parotids was lower for the plans optimized with IM. Treatment plan efficiency was higher for the DSS plans with (901 ± 160) MU compared to (1151 ± 157) MU for IM (p-value < 0.05). Renormalization of the IM plans to the mean of the dose to 95% of the PTV (D95) of the DSS plans, resulted in similar target coverage and dose to the parotids for both strategies, at the cost of a significantly higher dose to the normal tissue and maximum dose to the target. The relative volume of the PTV receiving 107% or more of the prescription dose V107 increased to 35.5% ± 20.0% for the IM plan as compared to a mean of 0.9% ± 0.9% for the DSS plan. Conclusion: The direct machine parameter optimization is a major improvement compared to the fluence modulation with subsequent leaf sequencing in Oncentra Masterplan v1.5. The resulting dose distribution complies better with the DVO and better plan quality is achieved for identical specification of DVO. An additional asset is the reduced number of MU as compared to IM.


  • Application of an inverse kernel concept to Monte Carlo based IMRT

    by Ludwig Bogner, Matthias Hartmann, Mark Rickhey, Zdenek Moravek

    Inverse treatment planning by means of pencil beam algorithms can lead to errors in the calculation of dose in areas without secondary electron equilibrium. Monte Carlo (MC) simulations give accurate results in such areas but result in increased computation times. We present a new, so-called inverse kernel concept that offers MC precision in inverse treatment planning with acceptable computation times and memory consumption. Inverse kernels are matrices that describe the dose contribution from all bixels of a beam to a distinct voxel of the patient phantom. The concept is similar to other generalized pencil-beam concepts, except that inverse kernel elements are precalculated using a single MC simulation and stored as binary trees. In this procedure a modified MC code (XVMC) is applied to trace the photon history for each dose deposition. Iterative optimization is then applied in a second step. The inverse process is separated into (i) a slower MC simulation and (ii) a faster iterative optimization, followed by (iii) the segmentation procedure, and (iv) a final MC dose calculation step including a segment weight reoptimization. Inverse kernel optimization, or IKO, with segmentation and reoptimization steps is demonstrated by means of a lung cancer case. To demonstrate the superiority of an inverse MC system over pencil-beam or collapsed-cone based systems, the final result of the IKO is compared to plans where all segments have been calculated by pencil beam or collapsed cone, respectively. Dose-volume histograms and dose-difference histograms show remarkable differences, which can be attributed to systematic errors in both algorithms. IKO is a precise, nonhybrid, inverse MC treatment planning system which suits current clinical needs, as several optimization steps can follow one single MC-simulation step for a distinct beam setup.


  • Verification of IMRT: Techniques and Problems

    by Ludwig Bogner, Josef Scherer, Marius Treutwein, Matthias Hartmann, Franz Gum, Axel Amediek


  • Preliminary study on the use of an inhomogeneous anthropomorphic Fricke gel phantom and 3D magnetic resonance dosimetry for verification of IMRT treatment plans

    by F Gum, J Scherer, L Bogner, M Solleder, B Rhein, M Bock

    An inhomogeneous anthropomorphic phantom of the human thorax including lungs and spine was developed for verification of three-dimensional (3D) intensity-modulated radiotherapy (IMRT). The phantom and spinal cord were filled with undiluted Fricke gel, whereas the lungs were filled with a special low-density Fricke gel. Based on a computed tomography scan of the phantom, an intensity-modulated stereotactic radiotherapy plan for a bronchial carcinoma was calculated using an inverse planning system (KonRad, DKFZ Heidelberg, Germany). The plan consisted of seven beams delivered in a step and shoot technique out of 67 sub-fields. Immediately after irradiation 3D magnetic resonance (MR) imaging of the phantom was performed using a special pulse sequence for T1 relaxometry. From the MR image data maps of the longitudinal relaxation rate R1 = 1/T1 were calculated. The R1 maps were converted to dose-proportional image data and compared to planning data. Measurement and planning show good agreement in regions of standard Fricke gel with an average deviation below 5%. In regions of the low-density Fricke gel, deviations are higher due to a decreased signal-to-noise ratio in the MR measurement. In these areas also a different sensitivity of the dose response was observed as compared to standard Fricke gel. The inhomogeneous thorax phantom has proven to be a useful pre-clinical tool for 3D methodical verifications.


  • Diagnostische Methoden zur Erkennung radiogener Spätschäden der Lunge

    by L. Bogner, I. Schießl, W. Spiegler, B. Meyer, M. Herbst

    The aim of this paper is to find techniques for quantifying radiation lung injury after irradiation with lung involvement to improve an early diagnosis. The case of a patient with NSCLC was used to demonstrate different methods in order to quantify a developing pneumopathy after radiation treatment. By means of HRCT studies in the follow-up, a procedure was developed by defining a test-ROI in high-dose areas of the lung and evaluating the corresponding HU-histogramm for the parameters of the lung peak. Changes during the follow-up can be derived from the differential HU-histogram by the determination of a parameter called delta HUrel, which quantifies the shift to higher HU values. Alternatively, a Fourier analysis of the lung pattern within the test-ROI results in a Fourier amplitude distribution, which reacts sensitively to changes during the follow-up. Furthermore, a Fourier-frequency histogram can be derived which is independent of the spatial orientation of the density pattern. From the HRCT follow-up study, values for delta HUrel can be derived to be 0.24, 0.44, and 0.50 (56, 100 and 422 days after beginning the treatment). The differential Fourier frequency-histogram presentations demonstrate pronounced pattern changes. The presented methods demonstrate possibilities to quantify radiation lung injury. The proven sensitivity can possibly be improved after the introduction of a breath triggered HRCT technique.