A prospective radiostereometric analysis of the stability of a metal-backed glenoid component/autograft composite in reverse shoulder arthroplasty
- 1 August 2023
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 105-B (8) , 912-919
Abstract
Aims: Reverse total shoulder arthroplasty (rTSA) can be used in complex cases when the glenoid requires reconstruction. In this study, a baseplate with composite bone autograft and a central trabecular titanium peg was implanted, and its migration was assessed for two years postoperatively using radiostereometric analysis (RSA).Methods: A total of 14 patients who underwent a rTSA with an autograft consented to participate. Of these, 11 had a primary rTSA using humeral head autograft and three had a revision rTSA with autograft harvested from the iliac crest. The mean age of the patients was 66 years (39 to 81). Tantalum beads were implanted in the scapula around the glenoid. RSA imaging (stereographic radiographs) was undertaken immediately postoperatively and at three, six, 12, and 24 months. Analysis was completed using model-based RSA software. Outcomes were collected preoperatively and at two years postoperatively, including the Oxford Shoulder Score, the American Shoulder and Elbow Score, and a visual analogue score for pain. A Constant score was also obtained for the assessment of strength and range of motion.Results: RSA analysis showed a small increase in all translation and rotational values up to six months postoperatively, consistent with settling of the implant. The mean values plateaued by 12 months, with no evidence of further migration. In four patients, there was significant variation outside the mean, which corresponded to postoperative complications. There was a significant improvement in the clinical and patient-reported outcomes from the preoperative values to those at two years postoperatively (p < 0.001).Conclusion: These findings show, using RSA, that a glenoid baseplate composite of a trabecular titanium peg with autograft stabilizes within the glenoid about 12 months after surgery, and reinforce findings from a previous study of this implant/graft with CT scans at two years postoperatively, indicating that this type of structural composite results in sound early fixation.Cite this article: Bone Joint J 2023;105-B(8):912–919.Keywords
This publication has 35 references indexed in Scilit:
- The early migration of a partially cemented fluted pegged glenoid component using radiostereometric analysisJournal of Shoulder and Elbow Surgery, 2012
- Reverse Total Shoulder Arthroplasty Improves Function in Cuff Tear ArthropathyClinical Orthopaedics and Related Research, 2011
- Reverse Prostheses in Arthropathies With Cuff Tear: Are Survivorship and Function Maintained Over Time?Clinical Orthopaedics and Related Research, 2011
- Bony Increased-offset Reversed Shoulder Arthroplasty: Minimizing Scapular Impingement While Maximizing Glenoid FixationClinical Orthopaedics and Related Research, 2011
- The Delta III reverse shoulder replacement for cuff tear arthropathyThe Journal of Bone and Joint Surgery. British volume, 2011
- Bone Grafting Severe Glenoid Defects in Revision Shoulder ArthroplastyClinical Orthopaedics and Related Research, 2008
- A study of the micromovement of pegged and keeled glenoid components compared using radiostereometric analysisJournal of Shoulder and Elbow Surgery, 2007
- Roentgen stereophotogrammetric analysis of metal‐backed hemispherical cups without attached markersJournal of Orthopaedic Research, 1997
- A standardized method for the assessment of shoulder functionJournal of Shoulder and Elbow Surgery, 1994
- Roentgen stereophotogrammetryActa Orthopaedica, 1989